5.02021-11-21T21:24:54ZTemplatesDelta UPS SNMP v1Delta UPS SNMP v1## Overview
Simple **SNMPv1** template for Delta UPS with LLD for lines.
Tested on Zabbix 3.0 but should works on older versions.
Required extra configuration:
Macro for {$SNMP\_COMMUNITY}
UPS-MIB
## Author
sim
TemplatesBatteryBypassLineDevice InformationICMPInputLineOutputLine- ICMP pingSIMPLEicmpping607dICMPService state{max(#3)}=0{HOST.NAME} is unavailable by ICMPAVERAGE
- ICMP lossSIMPLEicmppingloss607dFLOAT%ICMP{min(5m)}>20Ping loss is too high on {HOST.NAME}WARNING{HOST.NAME} is unavailable by ICMP{Delta UPS SNMP v1:icmpping.max(#3)}=0
- ICMP response timeSIMPLEicmppingsec607dFLOATsICMP{avg(5m)}>0.15Response time is too high on {HOST.NAME}WARNING{HOST.NAME} is unavailable by ICMP{Delta UPS SNMP v1:icmpping.max(#3)}=0
- UPS LocationSNMP_AGENTRFC1213-MIB::sysLocation.0sysLocation72000TEXTDevice Information
- UPS NameSNMP_AGENTRFC1213-MIB::sysName.0sysName72000TEXTDevice Information
- UPS Device uptimeSNMP_AGENTSNMPv2-MIB::sysUpTime.0sysUpTime.26014duptimeThe time since the network management portion of the system was last re-initialized.Device InformationMULTIPLIER0.01{last(,1m)}<5m{HOST.NAME}: UPS was restartedAVERAGE
- Battery Current Amp DCSNMP_AGENTUPS-MIB::upsBatteryCurrent.0upsBatteryCurrent607dAmp DCBattery
- UPS Battery StatusSNMP_AGENTUPS-MIB::upsBatteryStatus.0upsBatteryStatus6014dFLOATunknown(1),
batteryNormal(2),
batteryLow(3),
batteryDepleted(4)BatteryDelta Battery Status{diff(0)} = 1{HOST.NAME}: UPS Battery Status was changedAVERAGE
- UPS Battery VoltageSNMP_AGENTUPS-MIB::upsBatteryVoltage.0upsBatteryVoltage607dVolt DCBattery
- Number of Bypass LinesSNMP_AGENTUPS-MIB::upsBypassNumLines.0upsBypassNumLines72007dBypassLine
- Config Input FrequencySNMP_AGENTUPS-MIB::upsConfigInputFreq.0upsConfigInputFreq607dHertzInputLine
- Config Input VoltageSNMP_AGENTUPS-MIB::upsConfigInputVoltage.0upsConfigInputVoltage607dRMS VoltsInputLine
- Config Output FrequencySNMP_AGENTUPS-MIB::upsConfigOutputFreq.0upsConfigOutputFreq607dHertzOutputLine
- Config Output V-ASNMP_AGENTUPS-MIB::upsConfigOutputVA.0upsConfigOutputVA607dVolt-AmpsOutputLine
- Config Output VoltageSNMP_AGENTUPS-MIB::upsConfigOutputVoltage.0upsConfigOutputVoltage607dRMS VoltsOutputLine
- Battery Charge Level in %SNMP_AGENTUPS-MIB::upsEstimatedChargeRemaining.0upsEstimatedChargeRemaining3030dFLOAT%Battery{last(1m)}<10{HOST.NAME}: UPS Battery Charge Level < 10%DISASTER{last(1m)}<50{HOST.NAME}: UPS Battery Charge Level < 50%HIGH{HOST.NAME}: UPS Battery Charge Level < 50%{last(1m)}<90{HOST.NAME}: UPS Battery Charge Level < 90%AVERAGE{change()}>5{HOST.NAME}: UPS Battery Charge Level was changedAVERAGE
- UPS ManufacturerSNMP_AGENTRFC1213-MIB::mib-2.33.1.1.1.0upsIdentManufacturer72000TEXTDevice Information
- UPS ModelSNMP_AGENTRFC1213-MIB::mib-2.33.1.1.2.0upsIdentModel72000TEXTDevice Information
- Number of Input LinesSNMP_AGENTUPS-MIB::upsInputNumLines.0upsInputNumLines72007dInputLine
- Number of Output LinesSNMP_AGENTUPS-MIB::upsOutputNumLines.0upsOutputNumLines72007dOutputLine
- UPS Source TypeSNMP_AGENTUPS-MIB::upsOutputSource.0upsOutputSource30FLOATother(1),
none(2),
normal(3),
bypass(4),
battery(5),
booster(6),
reducer(7)Device InformationDelta Source Type{diff(0)} = 1{HOST.NAME}: UPS Power Source Type was changedHIGHMULTIPLE
UPS Bypass Line DiscoverySNMP_AGENTdiscovery[{#SNMPVALUE},UPS-MIB::upsBypassLineIndex]UPSBypassLineDiscovery7200UPS Line {#SNMPINDEX} Bypass VoltageSNMP_AGENTUPS-MIB::upsBypassVoltage.{#SNMPVALUE}.0upsBypassVoltage.[{#SNMPVALUE}]60RMS VoltsBypassLineUPS Input Line DiscoverySNMP_AGENTdiscovery[{#SNMPVALUE},UPS-MIB::upsInputLineIndex]UPSInputLineDiscovery7200UPS Input {#SNMPINDEX} CurrentSNMP_AGENTUPS-MIB::upsInputCurrent.{#SNMPVALUE}.0upsInputCurrent.[{#SNMPVALUE}]6014dRMS AmpInputLineUPS Input {#SNMPINDEX} FrequencySNMP_AGENTUPS-MIB::upsInputFrequency.{#SNMPVALUE}.0upsInputFrequency.[{#SNMPVALUE}]6014dHertzInputLineUPS Input {#SNMPINDEX} VoltageSNMP_AGENTUPS-MIB::upsInputVoltage.{#SNMPVALUE}.0upsInputVoltage.[{#SNMPVALUE}]6014dHertzInputLineUPS Output Line DiscoverySNMP_AGENTdiscovery[{#SNMPVALUE},UPS-MIB::upsOutputLineIndex]UPSOutputLineDiscovery7200UPS Line {#SNMPINDEX} Output VoltageSNMP_AGENTUPS-MIB::upsOutputCurrent.{#SNMPVALUE}.0upsOutputCurrent.[{#SNMPVALUE}]6014dFLOATRMS VoltsOutputLineUPS Line {#SNMPINDEX} Output Percent LoadSNMP_AGENTUPS-MIB::upsOutputPercentLoad.{#SNMPVALUE}.0upsOutputPercentLoad.[{#SNMPVALUE}]6014dFLOAT%OutputLine{avg(5m)}>60{HOST.NAME}: Line {#SNMPINDEX} load is greater than > 60%AVERAGE{avg(5m)}>80{HOST.NAME}: Line {#SNMPINDEX} load is greater than > 80%HIGHUPS Line {#SNMPINDEX} Output PowerSNMP_AGENTUPS-MIB::upsOutputPower.{#SNMPVALUE}.0upsOutputPower.[{#SNMPVALUE}]6014dFLOATWattsOutputLineUPS Line {#SNMPINDEX} Output CurrentSNMP_AGENTUPS-MIB::upsOutputVoltage.{#SNMPVALUE}.0upsOutputVoltage.[{#SNMPVALUE}]6014dRMS AmpOutputLineUPS Output Line {#SNMPINDEX} Load in %FIXED1A7C11- Delta UPS SNMP v1upsOutputPercentLoad.[{#SNMPVALUE}]
UPS Overview227050010000110000030Battery Charge Level in %Delta UPS SNMP v1500100101100000320UPS Output Line {#SNMPINDEX} Load in %Delta UPS SNMP v150010001110000033upsOutputSourceDelta UPS SNMP v15001001111500003Battery Charge Level in %1A7C11- Delta UPS SNMP v1upsEstimatedChargeRemaining
Uptime000088- Delta UPS SNMP v1sysUpTime.2
Delta Battery Status1unknown2batteryNormal3batteryLowDelta Source Type0unknown2none3normal4bypass5battery6booster7reducerService state0Down1Up