5.02021-11-21T21:42:22ZTemplatesStark-3000-snmpStark-3000-snmp## Overview
UPS Stark country 3000 online.
<https://en.stark-power.de>
Template based on "Template\_UPS\_Inform-flexipower"
## Author
Sergey Prisada
TemplatesBatteryEnvironmentalInformationPower- Extend work temperatureSNMP_AGENT1.3.6.1.4.1.21111.1.1.3.13.0iemStatusProbeCurrentTemp30CThe ambient temperature at or near the UPS Battery casing.Environmental{avg(30)}>400Ambient temperature criticalHIGH{avg(30)}>300Ambient temperature highWARNING{avg(30)}<150Ambient temperature too lowAVERAGE
- Ups bat est charge remainingSNMP_AGENT1.3.6.1.4.1.21111.1.1.3.1.0oid.companymib.upsbattery.upsbatstatus30%An estimate of the battery charge remaining expressed as a percent of full charge.BatteryMULTIPLIER0.01
- The present bypass frequencySNMP_AGENT1.3.6.1.4.1.21111.1.1.6.1.0PresentBypassFrequency30HzThe present bypass frequency.Environmental
- Battery voltageSNMP_AGENTiso.3.6.1.2.1.33.1.2.5.0upsAdvBatteryActualVoltage180VBattery
- Battery chargeSNMP_AGENT1.3.6.1.4.1.21111.1.1.3.4.0upsAdvBatteryCapacity30%An estimate of the battery charge remaining expressed as a percent of full charge.Battery{last(0)}<20Battery charge critically lowHIGH{last(0)}<50Battery charge lowWARNING
- Battery statusSNMP_AGENT1.3.6.1.4.1.21111.1.1.3.1.0upsAdvBatteryReplaceIndicator180The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than upsConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to upsConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is mandatoryly absent and the UPS is unable to sustain the output). unknown(1), batteryNormal(2), batteryLow(3), batteryDepleted(4), batteryDischarging(5), batteryFailure(6), batteryReplace(7), batterysilence(8)BatterySTARK Batary status{last()}=4Battery DepletedHIGH{last()}=6Battery FailureDISASTER{last()}=7Battery ReplaceDISASTER
- Input frequencySNMP_AGENT1.3.6.1.4.1.21111.1.1.6.1.0upsAdvInputFrequency180HzThe present bypass frequency.PowerMULTIPLIER0.1
- Input voltageSNMP_AGENTiso.3.6.1.4.1.21111.1.1.4.5.1.3.0upsAdvInputLineVoltage30VThe input utility line voltage.PowerMULTIPLIER0.1{avg(30)}<190Input voltage lowWARNING{avg(30)}>250Input voltage too highWARNING{avg(30)}=0No power inputDISASTERInput voltage is zero
- Load current in procentSNMP_AGENTiso.3.6.1.4.1.21111.1.1.5.7.1.7.0upsAdvOutputCurrent30%The percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA.Power{last(#10)}>=85OverloadDISASTER
- Output frequencySNMP_AGENT1.3.6.1.4.1.21111.1.1.5.2.0upsAdvOutputFrequency180HzThe current output frequency of the UPS systemPowerMULTIPLIER0.1
- Output voltageSNMP_AGENTiso.3.6.1.4.1.21111.1.1.5.7.1.2.0upsAdvOutputVoltage30VThe output voltage of the UPS system.PowerMULTIPLIER0.1
- UPS modelSNMP_AGENTiso.3.6.1.4.1.21111.1.1.1.3.0upsBasicIdentModel36000CHARMODELInformation
- UPS nameSNMP_AGENT1.3.6.1.4.1.21111.1.1.1.5.0upsIdentName36000CHARInformation
- UPS software versionSNMP_AGENT1.3.6.1.4.1.21111.1.1.1.6.0upsIdentUPSSoftwareVersion36000CHARInformation
Status130In-out Line StatusStark-3000-snmp50010000110000030Healt statusStark-3000-snmp50010001110000030Load statusStark-3000-snmp5001000211000003Healt status1A7C11- Stark-3000-snmpupsAdvBatteryCapacity
1F63100- Stark-3000-snmpupsAdvBatteryReplaceIndicator
22774A4- Stark-3000-snmpupsAdvBatteryActualVoltage
3A54F10- Stark-3000-snmpoid.companymib.upsbattery.upsbatstatus
In-out Line Status89ABF8- Stark-3000-snmpupsAdvInputFrequency
17EC25C- Stark-3000-snmpupsAdvInputLineVoltage
2274482- Stark-3000-snmpupsAdvOutputFrequency
32B5429- Stark-3000-snmpupsAdvOutputVoltage
Load statusSTACKED1A7C11- Stark-3000-snmpupsAdvBatteryCapacity
12774A4- Stark-3000-snmpupsAdvBatteryActualVoltage
2A54F10- Stark-3000-snmpPresentBypassFrequency
3FC6EA3- Stark-3000-snmpupsAdvOutputCurrent
46C59DC- Stark-3000-snmpPresentBypassFrequency
STARK Batary status1unknown2batteryNormal3batteryLow4batteryDepleted5batteryDischarging6batteryFailure7batteryReplace8batterysilence