5.02021-11-21T21:39:19ZTemplates/Servers HardwareCisco-UCSCisco-UCS## Overview
**Monitoring Cisco UCS Server for snmp v2 Working with B and C Blade server**
**tested on Cisco chassis 5018 and B200M4 .**
**it give you this info :**
* **Servers Hardware component info.**
* **Temperature monitoring .**
* **FAN** ****monitoring .****
* ****PSU**** ******monitoring .******
* ******Memory****** ************monitoring .************
* ************CPU************ ******************monitoring .******************
* ******************Network******************
******************you only need to add {$SNMP\_COMMUNITY} in macros******************
## Author
Bassam Darawshi
Templates/Servers HardwareCPUEquipmentFANGeneralMemoryNetworkPowerPSUTempreture- CPU utilizationSNMP_AGENT.1.3.6.1.4.1.9.9.109.1.1.1.1.8.1cpmCPUTotal5minRev10s%General{last()}>70CPU Usage on host {HOST.NAME}HIGHCPU Usage More Than 70%
- Memory utilizationSNMP_AGENT.1.3.6.1.4.1.9.9.305.1.1.2.0cseSysMemoryUtilization10s%General{last()}>80Memory Usage on host {HOST.NAME}HIGHMemory Usage More than 80
- System DescriptionSNMP_AGENT.1.3.6.1.2.1.1.1.0sysDescr3600s0TEXTGeneral
- System UpTimeSNMP_AGENT.1.3.6.1.2.1.1.3.0sysUpTime3600suptimeGeneral
BladeSNMP_AGENTdiscovery[{#SNMPVALUE},1.3.6.1.4.1.9.9.719.1.9.2.1.6]cucsComputeBladeAssignedToDn30s{#SNMPINDEX}: Admin StateSNMP_AGENT.1.3.6.1.4.1.9.9.719.1.9.2.1.5.{#SNMPINDEX}cucsComputeBladeAdminState[{#SNMPINDEX}]300sPowerCisco UCS Blade Admin State{#SNMPINDEX}: Available MemorySNMP_AGENT.1.3.6.1.4.1.9.9.719.1.9.2.1.9.{#SNMPINDEX}cucsComputeBladeAvailableMemory[{#SNMPINDEX}]300sMemory{#SNMPINDEX}: Last Power CycleSNMP_AGENT.1.3.6.1.4.1.9.9.719.1.9.2.1.19.{#SNMPINDEX}cucsComputeBladeFsmPrev[{#SNMPINDEX}]300s0TEXTPower{#SNMPINDEX}: Memory SpeedSNMP_AGENT.1.3.6.1.4.1.9.9.719.1.9.2.1.56.{#SNMPINDEX}cucsComputeBladeMemorySpeed[{#SNMPINDEX}]300sMemory{#SNMPINDEX}: Blade ModleSNMP_AGENT.1.3.6.1.4.1.9.9.719.1.9.2.1.32.{#SNMPINDEX}cucsComputeBladeModel[{#SNMPINDEX}]300s0TEXTEquipment{#SNMPINDEX}: Oper PowerSNMP_AGENT.1.3.6.1.4.1.9.9.719.1.9.2.1.40.{#SNMPINDEX}cucsComputeBladeOperPower[{#SNMPINDEX}]300sPowerCiscoPowerAdminType{#SNMPINDEX}: Blade NameSNMP_AGENT.1.3.6.1.4.1.9.9.719.1.9.2.1.3.{#SNMPINDEX}cucsComputeBladeRn[{#SNMPINDEX}]300s0TEXTEquipment{#SNMPINDEX}: Blade SerialSNMP_AGENT.1.3.6.1.4.1.9.9.719.1.9.2.1.47.{#SNMPINDEX}cucsComputeBladeSerial[{#SNMPINDEX}]300s0TEXTEquipment{#SNMPINDEX}: Slot IDSNMP_AGENT.1.3.6.1.4.1.9.9.719.1.9.2.1.49.{#SNMPINDEX}cucsComputeBladeSlotId[{#SNMPINDEX}]10sEquipmentCPUSNMP_AGENTdiscovery[{#SNMPVALUE},1.3.6.1.4.1.9.9.719.1.9.2.1.2]cucsComputeBladeDn10s{#SNMPINDEX}:Blade Num Of CoresSNMP_AGENT.1.3.6.1.4.1.9.9.719.1.9.2.1.35.{#SNMPINDEX}cucsComputeBladeNumOfCores[{#SNMPINDEX}]3600sCPU{#SNMPINDEX}:Blade Num Of CPUSSNMP_AGENT.1.3.6.1.4.1.9.9.719.1.9.2.1.36.{#SNMPINDEX}cucsComputeBladeNumOfCpus[{#SNMPINDEX}]3600sCPU{#SNMPINDEX}:Blade Num Of ThreadsSNMP_AGENT.1.3.6.1.4.1.9.9.719.1.9.2.1.39.{#SNMPINDEX}cucsComputeBladeNumOfThreads[{#SNMPINDEX}]3600sCPUCompute Board EntrySNMP_AGENTdiscovery[{#SNMPVALUE}, 1.3.6.1.4.1.9.9.719.1.9.6.1.2]cucsComputeBoardDn10s{#SNMPINDEX}: Board Oper PowerSNMP_AGENT1.3.6.1.4.1.9.9.719.1.9.6.1.7.{#SNMPINDEX}cucsComputeBoardOperPower[{#SNMPINDEX}]3600sPowerCiscoPowerAdminType{#SNMPINDEX}: Compute Board Power UsageSNMP_AGENT1.3.6.1.4.1.9.9.719.1.9.6.1.19.{#SNMPINDEX}cucsComputeBoardPowerUsage[{#SNMPINDEX}]3600sPowerBoard Power{#SNMPINDEX}: Board Compute VoltageSNMP_AGENT1.3.6.1.4.1.9.9.719.1.9.6.1.17.{#SNMPINDEX}cucsComputeBoardVoltage[{#SNMPINDEX}]3600sPowerBoard PowerPowerSNMP_AGENTdiscovery[{#SNMPVALUE},1.3.6.1.4.1.9.9.719.1.9.14.1.3]cucsComputeMbPowerStatsRn30s{#SNMPINDEX}: Blade Consumed Power AvgSNMP_AGENT.1.3.6.1.4.1.9.9.719.1.9.14.1.5.{#SNMPINDEX}cucsComputeMbPowerStatsConsumedPowerAvg[{#SNMPINDEX}]300sPower{#SNMPINDEX}: Blade Consumed Power MAXSNMP_AGENT.1.3.6.1.4.1.9.9.719.1.9.14.1.6.{#SNMPINDEX}cucsComputeMbPowerStatsConsumedPowerMax[{#SNMPINDEX}]300sPower{#SNMPINDEX}: Blade Consumed Power MINSNMP_AGENT.1.3.6.1.4.1.9.9.719.1.9.14.1.7.{#SNMPINDEX}cucsComputeMbPowerStatsConsumedPowerMin[{#SNMPINDEX}]300sPower{#SNMPINDEX}: Blade Consumed PowerSNMP_AGENT.1.3.6.1.4.1.9.9.719.1.9.14.1.4.{#SNMPINDEX}cucsComputeMbPowerStatsConsumedPower[{#SNMPINDEX}]300sPowerTempSNMP_AGENTdiscovery[{#SNMPVALUE},1.3.6.1.4.1.9.9.719.1.9.16.1.3]cucsComputeMbTempStatsRn30s{#SNMPINDEX}: Temp Stats AvgSNMP_AGENT.1.3.6.1.4.1.9.9.719.1.9.16.1.5.{#SNMPINDEX}cucsComputeMbTempStatsFmTempSenIoAvg[{#SNMPINDEX}]120sTempreture{#SNMPINDEX}:Blade Temp StatsSNMP_AGENT.1.3.6.1.4.1.9.9.719.1.9.16.1.4.{#SNMPINDEX}cucsComputeMbTempStatsFmTempSenIo[{#SNMPINDEX}]10sCTempreture{last()}>30Blade Temperature on host {HOST.NAME} is to highHIGHBlade Temperature more than 30C{last()}>40Blade Temperature on host {HOST.NAME} is to highHIGHBlade Temperature more than 40C{last()}>50Blade Temperature on host {HOST.NAME} is to highHIGHBlade Temperature more than 50C{#SNMPINDEX}: Temp Stats Rare AvgSNMP_AGENT.1.3.6.1.4.1.9.9.719.1.9.16.1.9.{#SNMPINDEX}cucsComputeMbTempStatsFmTempSenRearAvg[{#SNMPINDEX}]120sTempreture{#SNMPINDEX}: Temp Stats RareSNMP_AGENT.1.3.6.1.4.1.9.9.719.1.9.16.1.8.{#SNMPINDEX}cucsComputeMbTempStatsFmTempSenRear[{#SNMPINDEX}]120sTempreturejhjhgjh1A7C11- Cisco-UCScucsComputeMbTempStatsFmTempSenIo[{#SNMPINDEX}]
FANSNMP_AGENTdiscovery[{#SNMPVALUE},1.3.6.1.4.1.9.9.719.1.15.13.1.2]cucsEquipmentFanModuleDn10s{#SNMPINDEX}: FAN ModleSNMP_AGENT1.3.6.1.4.1.9.9.719.1.15.13.1.6.{#SNMPINDEX}cucsEquipmentFanModuleModel[{#SNMPINDEX}]300s0TEXTFAN{#SNMPINDEX}: OperabilitySNMP_AGENT1.3.6.1.4.1.9.9.719.1.15.13.1.7.{#SNMPINDEX}cucsEquipmentFanModuleOperability[{#SNMPINDEX}]60sFANBoard Power{#SNMPINDEX}: Operation StateSNMP_AGENT1.3.6.1.4.1.9.9.719.1.15.13.1.7.{#SNMPINDEX}cucsEquipmentFanModuleOperState[{#SNMPINDEX}]60sFANBoard Power{#SNMPINDEX}: Part NumberSNMP_AGENT1.3.6.1.4.1.9.9.719.1.15.13.1.20.{#SNMPINDEX}cucsEquipmentFanModulePartNumber[{#SNMPINDEX}]300s0TEXTFAN{#SNMPINDEX}: Operation PowerSNMP_AGENT1.3.6.1.4.1.9.9.719.1.15.13.1.10.{#SNMPINDEX}cucsEquipmentFanModulePower[{#SNMPINDEX}]60sFANBoard Power{#SNMPINDEX}: FAN NameSNMP_AGENT1.3.6.1.4.1.9.9.719.1.15.13.1.3.{#SNMPINDEX}cucsEquipmentFanModuleRn[{#SNMPINDEX}]300s0TEXTFAN{#SNMPINDEX}: FAN SerialSNMP_AGENT1.3.6.1.4.1.9.9.719.1.15.13.1.13.{#SNMPINDEX}cucsEquipmentFanModuleSerial[{#SNMPINDEX}]300s0TEXTFAN{#SNMPINDEX}: Operation PowerThermalSNMP_AGENT1.3.6.1.4.1.9.9.719.1.15.13.1.14.{#SNMPINDEX}cucsEquipmentFanModuleThermal[{#SNMPINDEX}]60sFANBoard Power{#SNMPINDEX}: FAN VendorSNMP_AGENT1.3.6.1.4.1.9.9.719.1.15.13.1.16.{#SNMPINDEX}cucsEquipmentFanModuleVendor[{#SNMPINDEX}]300s0TEXTFANPSUSNMP_AGENTdiscovery[{#SNMPVALUE},1.3.6.1.4.1.9.9.719.1.15.56.1.2]cucsEquipmentPsuDn30s{#SNMPINDEX}: PSU ModleSNMP_AGENT.1.3.6.1.4.1.9.9.719.1.15.56.1.6.{#SNMPINDEX}cucsEquipmentPsuModel[{#SNMPINDEX}]300s0TEXTPSU{#SNMPINDEX}: PSU OperabilitySNMP_AGENT.1.3.6.1.4.1.9.9.719.1.15.56.1.8.{#SNMPINDEX}cucsEquipmentPsuOperability[{#SNMPINDEX}]30sPSUBoard Power{#SNMPINDEX}: PSU Operation stateSNMP_AGENT.1.3.6.1.4.1.9.9.719.1.15.56.1.7.{#SNMPINDEX}cucsEquipmentPsuOperState[{#SNMPINDEX}]60sPSUBoard Power{#SNMPINDEX}: PSU PartNumberSNMP_AGENT.1.3.6.1.4.1.9.9.719.1.15.56.1.21.{#SNMPINDEX}cucsEquipmentPsuPartNumber[{#SNMPINDEX}]300s0TEXTPSU{#SNMPINDEX}: PSU NameSNMP_AGENT.1.3.6.1.4.1.9.9.719.1.15.56.1.3.{#SNMPINDEX}cucsEquipmentPsuRn[{#SNMPINDEX}]300s0TEXTPSU{#SNMPINDEX}: PSU SerialSNMP_AGENT.1.3.6.1.4.1.9.9.719.1.15.56.1.13.{#SNMPINDEX}cucsEquipmentPsuSerial[{#SNMPINDEX}]300s0TEXTPSU{#SNMPINDEX}: PSU ThermalSNMP_AGENT.1.3.6.1.4.1.9.9.719.1.15.56.1.14.{#SNMPINDEX}cucsEquipmentPsuThermal[{#SNMPINDEX}]60sPSUBoard PowerNetworkRxSNMP_AGENTdiscovery[{#SNMPVALUE},1.3.6.1.4.1.9.9.719.1.16.9.1.3]cucsEtherRxStatsRn30s10d{#SNMPINDEX}:Rx Broadcast PacketsSNMP_AGENT.1.3.6.1.4.1.9.9.719.1.16.9.1.4.{#SNMPINDEX}cucsEtherRxStatsBroadcastPackets[{#SNMPINDEX}]5s10d15dBNetwork{#SNMPINDEX}:Rx Interface NameSNMP_AGENT.1.3.6.1.4.1.9.9.719.1.16.9.1.2.{#SNMPINDEX}cucsEtherRxStatsDn[{#SNMPINDEX}]300s10d0TEXTNetwork{#SNMPINDEX}:Rx Jumbo PacketsSNMP_AGENT.1.3.6.1.4.1.9.9.719.1.16.9.1.10.{#SNMPINDEX}cucsEtherRxStatsJumboPackets[{#SNMPINDEX}]5s10d15dBNetwork{#SNMPINDEX}:Rx Multicast PacketsSNMP_AGENT.1.3.6.1.4.1.9.9.719.1.16.9.1.15.{#SNMPINDEX}cucsEtherRxStatsMulticastPackets[{#SNMPINDEX}]5s10d15dBNetwork{#SNMPINDEX}:Rx Total BytesSNMP_AGENT.1.3.6.1.4.1.9.9.719.1.16.9.1.23.{#SNMPINDEX}cucsEtherRxStatsTotalBytes[{#SNMPINDEX}]5s10d15dBNetwork{#SNMPINDEX}:Rx Unicast PacketsSNMP_AGENT.1.3.6.1.4.1.9.9.719.1.16.9.1.33.{#SNMPINDEX}cucsEtherRxStatsUnicastPackets[{#SNMPINDEX}]5s10d15dBNetworkNetworkTxSNMP_AGENTdiscovery[{#SNMPVALUE},1.3.6.1.4.1.9.9.719.1.16.14.1.3]cucsEtherTxStatsRn30s10d{#SNMPINDEX}:Rx Broadcast PacketsSNMP_AGENT.1.3.6.1.4.1.9.9.719.1.16.14.1.4.{#SNMPINDEX}cucsEtherTxStatsBroadcastPackets[{#SNMPINDEX}]5s10d15dBNetwork{#SNMPINDEX}:Tx Interface NameSNMP_AGENT.1.3.6.1.4.1.9.9.719.1.16.14.1.2.{#SNMPINDEX}cucsEtherTxStatsDn[{#SNMPINDEX}]5s10d0TEXTNetwork{#SNMPINDEX}:Tx Jumbo PacketsSNMP_AGENT.1.3.6.1.4.1.9.9.719.1.16.14.1.10.{#SNMPINDEX}cucsEtherTxStatsJumboPackets[{#SNMPINDEX}]5s10d15dBNetwork{#SNMPINDEX}:Tx Multicast PacketsSNMP_AGENT.1.3.6.1.4.1.9.9.719.1.16.14.1.15.{#SNMPINDEX}cucsEtherTxStatsMulticastPackets[{#SNMPINDEX}]5s10d15dBNetwork{#SNMPINDEX}:Tx Total BytesSNMP_AGENT.1.3.6.1.4.1.9.9.719.1.16.14.1.23.{#SNMPINDEX}cucsEtherTxStatsTotalBytes[{#SNMPINDEX}]5s10d15dBNetwork{#SNMPINDEX}:Tx Unicast PacketsSNMP_AGENT.1.3.6.1.4.1.9.9.719.1.16.14.1.33.{#SNMPINDEX}cucsEtherTxStatsUnicastPackets[{#SNMPINDEX}]5s10d15dBNetworkCPU utilization1A7C11- Cisco-UCScpmCPUTotal5minRev
Memory utilization1A7C11- Cisco-UCScseSysMemoryUtilization
Board Power1OK2not OK3not OK4not OK5not OK6not OKCiscoPowerAdminType1on2off3inlineAuto4inlineOn5powerCycleCisco UCS Blade Admin State1in-service2maintenance3out-of-service