zabbix_export: version: '5.4' date: '2021-11-21T21:23:44Z' groups: - uuid: 7df96b18c230490a9a0a9e2307226338 name: Templates templates: - uuid: 91275bcefed24fb39346f94f64fc2eeb template: 'Dell iDrac SNMPV2' name: 'Dell idrac' description: | ## Overview 这是[https://share.zabbix.com/network\_devices/cat-dell-sonicwall/dell-idrac](network_devices/cat-dell-sonicwall/dell-idrac)的中文化版本,同时进行了修正以支持zabbix3.0,感谢原作者 groups: - name: Templates items: - uuid: 73aa2445cb81473fb4429d937f4b723b name: 'BIOS 生产日期' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.674.10892.5.4.300.50.1.7.1.1 key: BiosDate delay: '86400' history: 7d trends: '0' value_type: CHAR tags: - tag: Application value: 'System Info' - uuid: 4a7762be06cd4234a0782ea57c381625 name: 'BIOS 版本' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.674.10892.5.4.300.50.1.8.1.1 key: BiosVersion delay: '86400' trends: '0' value_type: CHAR tags: - tag: Application value: 'System Info' - uuid: 046d84211efe48e2afbab88b18a6b9cf name: 'CMOS 电池状态' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.674.10892.5.4.600.50.1.5.1.1 key: CMOSBatteryStatus delay: '60' valuemap: name: 'Dell Open Manage System Status' tags: - tag: Application value: 'System Info' triggers: - uuid: 4e69dcd1eeb54880b8d810ee0e0d194f expression: 'last(/Dell iDrac SNMPV2/CMOSBatteryStatus)<>3' name: '物理机 {HOST.NAME} CMOS 电池异常' priority: WARNING - uuid: 1fc551631faf4c5982d616bdd4806ce4 name: 系统状态 type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.674.10892.2.2.1.0 key: GlobalSystemStatus delay: '60' history: 7d valuemap: name: 'Dell Open Manage System Status' tags: - tag: Application value: 'System Info' triggers: - uuid: 52ade3da25324ca29593baa6db0c834d expression: 'nodata(/Dell iDrac SNMPV2/GlobalSystemStatus,300s)' name: '物理机 {HOST.NAME} iDrac 5分钟无数据' priority: WARNING - uuid: 6ada6b9eceaf4427aead48a286584222 expression: 'last(/Dell iDrac SNMPV2/GlobalSystemStatus)>4' name: '物理机 {HOST.NAME} 发生严重错误' priority: DISASTER - uuid: 644ad56355804ceca63a191a45200690 name: 'iDRAC 访问地址' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.674.10892.2.1.1.7.0 key: idrac_acessurl delay: '86400' history: 7d trends: '0' value_type: CHAR inventory_link: URL_A tags: - tag: Application value: 'System Info' - uuid: a0ee2de522fe4461b16960c6db631716 name: 标记号 type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.674.10892.2.1.1.11.0 key: idrac_assettag delay: '86400' history: 7d trends: '0' value_type: CHAR inventory_link: ASSET_TAG tags: - tag: Application value: 'System Info' - uuid: 52d1b97c9e9247c6a9f70712bc433f11 name: 系统服务号 type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.674.10892.5.1.3.3.0 key: idrac_esc delay: '86400' trends: '0' value_type: CHAR tags: - tag: Application value: 'System Info' - uuid: 3e33c15be96b4cdd922ec76ef4af1e08 name: 'iDRAC 固件版本' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.674.10892.2.1.1.5.0 key: idrac_firmwareversion delay: '86400' history: 7d trends: '0' value_type: CHAR tags: - tag: Application value: 'System Info' - uuid: e9f2d357254c4078800f93bf8d8a6f1d name: 型号 type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.674.10892.5.1.3.12.0 key: idrac_SystemModel delay: '86400' trends: '0' value_type: CHAR inventory_link: MODEL tags: - tag: Application value: 'System Info' - uuid: ef184097d4694a1aa59001a023ff3d4e name: 'iDRAC 版本' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.674.10892.2.1.1.2.0 key: idrac_version delay: '86400' history: 7d trends: '0' value_type: CHAR tags: - tag: Application value: 'System Info' - uuid: 96609719c7d7402ba3732aa62d3f91dd name: 电源无功功率 type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.674.10892.5.4.600.60.1.15.1.1 key: PowerUsageMinIdle delay: '120' units: W tags: - tag: Application value: Power - uuid: 10b04635fff14e03b1a40d52928d6a72 name: 电源传感器状态 type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.674.10892.5.4.600.60.1.5.1.1 key: PowerUsageSensorStatus delay: '120' history: 7d trends: '0' valuemap: name: 'Dell Open Manage System Status' tags: - tag: Application value: Power - uuid: b0f37c5d72b3474c830117fbd5c5d76b name: 'RAID 控制器固件版本' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.8.1 key: RAIDControllerFirmware delay: '86400' history: 7d trends: '0' value_type: CHAR tags: - tag: Application value: 'Disks / Storage' - uuid: 710df271dcf9419981961e30c26b401d name: 'RAID 控制器名称' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.2.1 key: RAIDControllerName delay: '86400' history: 7d trends: '0' value_type: CHAR tags: - tag: Application value: 'Disks / Storage' - uuid: 31f734a59199421ea2742c7f9ad4ca16 name: 'RAID 控制器状态' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.37.1 key: RAIDControllerStatus delay: '60' history: 7d trends: '0' valuemap: name: 'Dell Open Manage System Status' tags: - tag: Application value: 'Disks / Storage' triggers: - uuid: d1a812b1dd5741fea5019941900784c6 expression: 'last(/Dell iDrac SNMPV2/RAIDControllerStatus)<>3' name: '物理机 {HOST.NAME} raid控制器错误' priority: HIGH - uuid: 6070646a56d641859e9584bd4fbcc740 name: 'BIOS 状态' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.674.10892.5.4.300.50.1.5.1.1 key: SystemBiosStatus delay: '60' history: 7d trends: '0' valuemap: name: 'Dell Open Manage System Status' tags: - tag: Application value: 'System Info' - uuid: fc9086bf23c3473c85b1c7013699a067 name: 电压状态 type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.12.1 key: VoltageStatusCombined delay: '120' history: 7d trends: '0' valuemap: name: 'Dell Open Manage System Status' tags: - tag: Application value: Voltages triggers: - uuid: ece3243a6dc94918ba8627962271c069 expression: 'last(/Dell iDrac SNMPV2/VoltageStatusCombined)<>3' name: '物理机 {HOST.NAME} 电压异常' priority: HIGH discovery_rules: - uuid: 560514efacfc4eeda9c69ff12c401c88 name: 'Disk Enumeration' type: SNMP_AGENT snmp_oid: 'discovery[{#DISKNAME}, 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.2]' key: DiskEnumeration delay: '7200' item_prototypes: - uuid: 9043c94e02764e8d8af0e198e67c57fa name: '磁盘 {#DISKNAME} : 生产日' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.32.{#SNMPINDEX}' key: 'DiskManufactureDay.[{#SNMPINDEX}]' delay: '86400' history: 7d trends: '0' tags: - tag: Application value: 'Disks / Storage' - uuid: 019ba2296cb4418c8d7b2cdd98561cc1 name: '磁盘 {#SNMPINDEX} : 制造商' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.3.{#SNMPINDEX}' key: 'DiskManufacturer.[{#SNMPINDEX}]' delay: '86400' history: 7d trends: '0' value_type: CHAR tags: - tag: Application value: 'Disks / Storage' - uuid: cdc2ab407271448596824de1a2bf1e05 name: '磁盘 {#SNMPINDEX} : 生产周' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.33.{#SNMPINDEX}' key: 'DiskManufactureWeek.[{#SNMPINDEX}]' delay: '86400' history: 7d trends: '0' tags: - tag: Application value: 'Disks / Storage' - uuid: 4d86cfb085354783bfa4f37115cb1f21 name: '磁盘 {#DISKNAME} : 生产年份' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.34.{#SNMPINDEX}' key: 'DiskManufactureYear.[{#SNMPINDEX}]' delay: '86400' history: 7d trends: '0' tags: - tag: Application value: 'Disks / Storage' - uuid: 4840ddbc8f08457a841cc1d011a27ca9 name: '磁盘 {#DISKNAME} : 型号' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.6.{#SNMPINDEX}' key: 'DiskModel.[{#SNMPINDEX}]' delay: '86400' history: 7d trends: '0' value_type: CHAR tags: - tag: Application value: 'Disks / Storage' - uuid: ee32681682a7472aae842fc2eddbf1fc name: '磁盘 {#DISKNAME} : 名称' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.55.{#SNMPINDEX}' key: 'DiskName.[{#SNMPINDEX}]' delay: '86400' history: 7d trends: '0' value_type: CHAR tags: - tag: Application value: 'Disks / Storage' - uuid: 04b46f7fbe2642db9af438e6bbe4f6bf name: '磁盘 {#DISKNAME} : 序列号' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.7.{#SNMPINDEX}' key: 'DiskSerialNo.[{#SNMPINDEX}]' delay: '86400' history: 7d trends: '0' value_type: CHAR tags: - tag: Application value: 'Disks / Storage' - uuid: 5d7d9057da3d429bb30d59d88e5e1175 name: '磁盘 {#DISKNAME} : 磁盘大小' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.11.{#SNMPINDEX}' key: 'DiskSize.[{#SNMPINDEX}]' delay: '86400' history: 7d trends: '0' units: B preprocessing: - type: MULTIPLIER parameters: - '1048576' tags: - tag: Application value: 'Disks / Storage' - uuid: dd3a5a1eba99418e8a2e439a0d63b9a8 name: '磁盘 {#DISKNAME} : 状态' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.4.{#SNMPINDEX}' key: 'DiskState.[{#SNMPINDEX}]' delay: '300' history: 7d valuemap: name: DellDracDiskState tags: - tag: Application value: 'Disks / Storage' - uuid: 0449c0a5cb124c97b2003e8c3e0d75fe name: 'Fan Enumeration' type: SNMP_AGENT snmp_oid: 'discovery[{#FAN}, 1.3.6.1.4.1.674.10892.5.4.700.12.1.8.1]' key: FanEnumeration delay: '7200' item_prototypes: - uuid: f44dd0d685984af1ad13b8b70cfd3656 name: '风扇 {#FAN} 转速' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.4.700.12.1.6.1.{#SNMPINDEX}' key: 'FanSpeed.[{#SNMPINDEX}]' delay: '120' units: rpm tags: - tag: Application value: Fans - uuid: 66969842bc4e4a7fb29316449a5910eb name: '风扇 {#FAN} 状态' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.4.700.12.1.5.1.{#SNMPINDEX}' key: 'FanStatus.[{#SNMPINDEX}]' delay: '120' history: 7d valuemap: name: 'Dell Open Manage System Status' tags: - tag: Application value: Fans trigger_prototypes: - uuid: df5cfccec13142f7a4b571ad748d8d66 expression: 'last(/Dell iDrac SNMPV2/FanStatus.[{#SNMPINDEX}])<>3' name: '物理机 {HOSTNAME} 风扇 {#FAN} 异常' priority: AVERAGE graph_prototypes: - uuid: d1c7a47352a84d239061ad35be87f93c name: 'FAN {#FAN}' graph_items: - color: C80000 item: host: 'Dell iDrac SNMPV2' key: 'FanSpeed.[{#SNMPINDEX}]' - uuid: bb4a93a4aa2f4cbabed9eced2bcf098d name: 'Memory Enumeration' type: SNMP_AGENT snmp_oid: 'discovery[{#MEM},1.3.6.1.4.1.674.10892.5.4.1100.50.1.8.1]' key: MemoryEnum delay: '43200;50/1-7,00:00-24:00' item_prototypes: - uuid: df3788f6e98843c681f1e2beaa60ba74 name: '内存 {#MEM} 制造商' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.4.1100.50.1.21.1.{#SNMPINDEX}' key: 'MemManufacturer[{#SNMPINDEX}]' delay: '86400' history: 7d trends: '0' value_type: CHAR tags: - tag: Application value: Memory - uuid: bf5472b1a13d43149d4655768f94ad9f name: '内存 {#MEM} 序列号' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.4.1100.50.1.23.1.{#SNMPINDEX}' key: 'MemSerialNo.[{#SNMPINDEX}]' delay: '86400' history: 7d trends: '0' value_type: CHAR tags: - tag: Application value: Memory - uuid: 880ce04bc5ec45ac9c7325c0537ed7f7 name: '内存 {#MEM} 大小' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.4.1100.50.1.14.1.{#SNMPINDEX}' key: 'MemSize.[{#SNMPINDEX}]' delay: '86400' history: 7d trends: '0' units: B preprocessing: - type: MULTIPLIER parameters: - '1024' tags: - tag: Application value: Memory - uuid: 51698ce862af4b09b1b9d653ebb96362 name: '内存 {#MEM} 速度' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.4.1100.50.1.15.1.{#SNMPINDEX}' key: 'MemSpeed.[{#SNMPINDEX}]' delay: '86400' history: 7d trends: '0' units: MHz tags: - tag: Application value: Memory - uuid: 7025eebce5154e9ba53863dd2dded309 name: '内存 {#MEM} 状态' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.4.1100.50.1.5.1.{#SNMPINDEX}' key: 'MemStatus.[{#SNMPINDEX}]' delay: '60' history: 7d valuemap: name: 'Dell Open Manage System Status' tags: - tag: Application value: Memory trigger_prototypes: - uuid: fc349c9b567641a294e327f4fd37eddc expression: 'last(/Dell iDrac SNMPV2/MemStatus.[{#SNMPINDEX}])<>3' name: '物理机{HOST.NAME} 内存 {#MEM} 错误' priority: HIGH - uuid: 9920cfc033024d50b6a99e4a13095e5c name: 'Network Enumeration' type: SNMP_AGENT snmp_oid: 'discovery[{#NETIF},1.3.6.1.4.1.674.10892.5.4.1100.90.1.2.1]' key: NetworkEnum delay: '7200' item_prototypes: - uuid: 633d8103c6d84071bc43366b9f29f11a name: '网卡 {#NETIF} : 连接状态' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.4.1100.90.1.4.1.{#SNMPINDEX}' key: 'NetConnStatus.[{#SNMPINDEX}]' delay: '120' history: 7d valuemap: name: 'Dell iDRAC Network Device Connection Status' tags: - tag: Application value: 'Network Cards' trigger_prototypes: - uuid: 6e8c80b246c3483682d54c3e93a49cb4 expression: '(last(/Dell iDrac SNMPV2/NetConnStatus.[{#SNMPINDEX}],#1)<>last(/Dell iDrac SNMPV2/NetConnStatus.[{#SNMPINDEX}],#2))=1' name: '物理机 {#HOSTNAME} 网卡 {#NETIF} 状态变化' priority: WARNING - uuid: ec3efdbdd6a041289017c7862f278179 name: '网卡 {#NETIF} : 名称' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.4.1100.90.1.6.1.{#SNMPINDEX}' key: 'NetName.[{#SNMPINDEX}]' delay: '86400' history: 7d trends: '0' value_type: CHAR tags: - tag: Application value: 'Network Cards' - uuid: 572ccc5fb97b43b9be93e7f983c708e5 name: '网卡 {#NETIF} : 槽位' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.4.1100.90.1.30.1.{#SNMPINDEX}' key: 'NetSlot.[{#SNMPINDEX}]' delay: '86400' history: 7d trends: '0' value_type: CHAR tags: - tag: Application value: 'Network Cards' - uuid: 5cc69ef5a49446c7ad41bb01edb87b6b name: '网卡 {#NETIF} : 状态' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.4.1100.90.1.3.1.{#SNMPINDEX}' key: 'NetStatus.[{#SNMPINDEX}]' delay: '60' history: 7d valuemap: name: 'Dell Open Manage System Status' tags: - tag: Application value: 'Network Cards' trigger_prototypes: - uuid: 02b7cff0786c46568f6903f360ec614b expression: 'last(/Dell iDrac SNMPV2/NetStatus.[{#SNMPINDEX}])<>3' name: '物理机{HOST.NAME} 网卡 {#NETIF} 状态异常' priority: HIGH - uuid: cda23704a4224cd3818c4c8b03c89195 name: 'Power Supply Enumeration' type: SNMP_AGENT snmp_oid: 'discovery[{#POWER},1.3.6.1.4.1.674.10892.5.4.600.12.1.1.1]' key: PowerSupplies delay: '7200' item_prototypes: - uuid: 2b3744962c004f8b871b6e5184b82f74 name: '电源 {#POWER} 输入电压' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.4.600.12.1.9.1.{#SNMPINDEX}' key: 'PowerSupplyInputVoltage.[{#SNMPINDEX}]' delay: '300' history: 7d value_type: FLOAT units: V tags: - tag: Application value: Power - uuid: 43eb959ad9f346f98966ebdba38bd20c name: '电源 {#POWER} 最大功率' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.4.600.12.1.6.1.{#SNMPINDEX}' key: 'PowerSupplyMaxPower.[{#SNMPINDEX}]' delay: '86400' history: 7d trends: '0' value_type: FLOAT units: W preprocessing: - type: MULTIPLIER parameters: - '0.1' tags: - tag: Application value: Power - uuid: c1eea44199604805be5afdcb92f36cdf name: '电源 {#POWER} 传感器状态' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.4.600.12.1.11.1.{#SNMPINDEX}' key: 'PowerSupplySensorState.[{#SNMPINDEX}]' delay: '300' history: 7d valuemap: name: Dell_PSU_SensorState tags: - tag: Application value: Power trigger_prototypes: - uuid: 42793401524046a08870fd8178da674b expression: 'last(/Dell iDrac SNMPV2/PowerSupplySensorState.[{#SNMPINDEX}])<>1' name: '物理机 {HOST.NAME} 电源 {#POWER} 状态异常' priority: HIGH - uuid: 369589cb0e3843d7a6dba4d299f10af3 name: '电源 {#POWER} 状态' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.4.600.12.1.4.1.{#SNMPINDEX}' key: 'PowerSupplyStateSettings.[{#SNMPINDEX}]' delay: '120' history: 7d valuemap: name: 'Dell PSU State Settings' tags: - tag: Application value: Power - uuid: 0157551c8ac945379a587bd97e5c9b99 name: 'Processor Enumeration' type: SNMP_AGENT snmp_oid: 'discovery[{#CPU},1.3.6.1.4.1.674.10892.5.4.1100.32.1.7.1]' key: ProcEnum delay: '43200' item_prototypes: - uuid: 125cf01fc73845c4a69bda9fda0268a9 name: '处理器 {#SNMPINDEX} 状态' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.4.1100.32.1.5.1.{#SNMPINDEX}' key: 'ProcStatus.[{#SNMPINDEX}]' delay: '300' history: 7d trends: '0' valuemap: name: 'Dell Open Manage System Status' tags: - tag: Application value: 'System Info' trigger_prototypes: - uuid: 9bdf76e1a3c44dae8081e125029bba35 expression: '(last(/Dell iDrac SNMPV2/ProcStatus.[{#SNMPINDEX}])<>3 and last(/Dell iDrac SNMPV2/ProcStatus.[{#SNMPINDEX}])<>2) or (last(/Dell iDrac SNMPV2/ProcStatus.[{#SNMPINDEX}])<>2 and last(/Dell iDrac SNMPV2/ProcStatus.[{#SNMPINDEX}])=2)' name: '物理机 {HOST.NAME} 处理器 {#SNMPINDEX} 状态异常' priority: HIGH - uuid: 2c04580e24834505946640cfd335ba7d name: 'Temperature Enumeration' type: SNMP_AGENT snmp_oid: 'discovery[{#TEMP},1.3.6.1.4.1.674.10892.5.4.700.20.1.8.1]' key: TempEnum delay: '7200' item_prototypes: - uuid: 8cb75f7320a4414b8723b3d2931ec5d3 name: '温度传感器 {#TEMP} 状态' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.4.700.20.1.5.1.{#SNMPINDEX}' key: 'TempStatus.[{#SNMPINDEX}]' delay: '300' history: 7d trends: '0' valuemap: name: 'Dell Open Manage System Status' tags: - tag: Application value: Temperatures trigger_prototypes: - uuid: 40941970707b4b01bae7b0e0325fa3b5 expression: 'last(/Dell iDrac SNMPV2/TempStatus.[{#SNMPINDEX}])<>3' name: '物理机 {HOST.NAME} 温度传感器 {#TEMP} 状态异常' priority: HIGH - uuid: 0090b6fe4c5641619fcd3a0256d4e528 name: '温度传感器 {#TEMP} 温度值' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.4.700.20.1.6.1.{#SNMPINDEX}' key: 'TempValue.[{#SNMPINDEX}]' delay: '60' history: 7d value_type: FLOAT units: C valuemap: name: 'Dell Open Manage System Status' preprocessing: - type: MULTIPLIER parameters: - '0.1' tags: - tag: Application value: Temperatures graph_prototypes: - uuid: ebf3980d94164d408c76b082aa45c222 name: 'Temperature on sensor {#TEMP}' graph_items: - color: C80000 calc_fnc: ALL item: host: 'Dell iDrac SNMPV2' key: 'TempValue.[{#SNMPINDEX}]' - uuid: c04ee69b9a7742d2a26b710225ebf922 name: 'Voltage Table Enumeration' type: SNMP_AGENT snmp_oid: 'discovery[{#VOLTAGE}, 1.3.6.1.4.1.674.10892.5.4.600.20.1.8.1]' key: VoltageTable delay: '7200' item_prototypes: - uuid: 63e9dcf3b06241bda4c39a15feb6d7e6 name: '组件 {#VOLTAGE} : 电压状态' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.4.600.20.1.5.1.{#SNMPINDEX}' key: 'VoltageStatus.[{#SNMPINDEX}]' delay: '120' history: 7d trends: '0' valuemap: name: 'Dell Open Manage System Status' tags: - tag: Application value: Voltages trigger_prototypes: - uuid: e69e9c8c6bba41dcb8bc2bc53f78be45 expression: 'last(/Dell iDrac SNMPV2/VoltageStatus.[{#SNMPINDEX}])<>3' name: '物理机 {HOST.NAME} 电压组件 {#VOLTAGE} 异常' priority: AVERAGE - uuid: 61dfd92fa6c84deb9e61e3bb3b862e0a name: 'Disk Volume Enumeration' type: SNMP_AGENT snmp_oid: 'discovery[{#VOLNAME},1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.1]' key: VolumeEnum delay: '7200' item_prototypes: - uuid: af3d81bcc3764a9987c964f1e2c5073e name: '磁盘卷 {#VOLNAME} : 状态' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.4.{#SNMPINDEX}' key: 'VolumeDiskState.[{#SNMPINDEX}]' delay: '90' history: 7d valuemap: name: DellRaidVolumeState tags: - tag: Application value: 'Disks / Storage' trigger_prototypes: - uuid: 375abf5abbba4857913fb4c80db9b729 expression: 'last(/Dell iDrac SNMPV2/VolumeDiskState.[{#SNMPINDEX}])<>2' name: '物理机{HOST.NAME} 磁盘卷 {#VOLNAME} 错误' priority: HIGH - uuid: a7afe7bb930941d39290825efcf57f46 name: '磁盘卷 {#SNMPINDEX} : 名称' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.36.{#SNMPINDEX}' key: 'VolumeName.[{#SNMPINDEX}]' delay: '86400' history: 7d trends: '0' value_type: CHAR tags: - tag: Application value: 'Disks / Storage' - uuid: 683ab02f27ae4893aff299a7e36b7490 name: '磁盘卷 {#SNMPINDEX} : 大小' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.6.{#SNMPINDEX}' key: 'VolumeSize.[{#SNMPINDEX}]' delay: '86400' history: 7d trends: '0' units: B preprocessing: - type: MULTIPLIER parameters: - '1048576' tags: - tag: Application value: 'Disks / Storage' - uuid: 9d880f15bd544b4aa14c8a329ff1ebd0 name: '磁盘卷 {#SNMPINDEX} : Raid级别' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.13.{#SNMPINDEX}' key: 'VolumeState.[{#SNMPINDEX}]' delay: '3600' history: 7d trends: '0' valuemap: name: DellRaidLevel tags: - tag: Application value: 'Disks / Storage' macros: - macro: '{$SNMP_COMMUNITY}' value: public valuemaps: - uuid: 9cfd3158181644e59b66332324f138cd name: DellDracDiskState mappings: - value: '1' newvalue: Unknown - value: '2' newvalue: Ready - value: '3' newvalue: Online - value: '4' newvalue: Foreign - value: '5' newvalue: Offline - value: '6' newvalue: Blocked - value: '7' newvalue: Failed - value: '8' newvalue: Non-RAID - value: '9' newvalue: Removed - uuid: 94e0bd73dc1e470e9a9ecad342c3c1a3 name: 'Dell iDRAC Network Device Connection Status' mappings: - value: '1' newvalue: Up - value: '2' newvalue: Down - value: '3' newvalue: driverBad - value: '4' newvalue: driverDisabled - value: '10' newvalue: hardwareInitalizing - value: '11' newvalue: hardwareResetting - value: '12' newvalue: hardwareClosing - value: '13' newvalue: hardwareNotReady - uuid: 0c7cf9591cbc4e0e88bf76f7b17e9cd2 name: 'Dell Open Manage System Status' mappings: - value: '1' newvalue: Other - value: '2' newvalue: Unknown - value: '3' newvalue: OK - value: '4' newvalue: NonCritical - value: '5' newvalue: Critical - value: '6' newvalue: NonRecoverable - uuid: dba3e483d19a4fd0893e83220d59bfd8 name: 'Dell PSU State Settings' mappings: - value: '1' newvalue: Unknown - value: '2' newvalue: 'Online (state disabled)' - value: '4' newvalue: 'not Ready' - value: '8' newvalue: 'Fan Failure' - value: '10' newvalue: 'Online and Fan Failure' - value: '16' newvalue: 'on' - value: '242' newvalue: 'Online and OK' - uuid: 0264d1b4583f4ee7be730f6b5943fbe1 name: DellRaidLevel mappings: - value: '1' newvalue: Unknown - value: '2' newvalue: RAID-0 - value: '3' newvalue: RAID-1 - value: '4' newvalue: RAID-5 - value: '5' newvalue: RAID-6 - value: '6' newvalue: RAID-10 - value: '7' newvalue: RAID-50 - value: '8' newvalue: RAID-60 - value: '9' newvalue: 'Concatenated RAID 1' - value: '10' newvalue: 'Concatenated RAID 5' - uuid: b709ae951d134af0934d379d89084865 name: DellRaidVolumeState mappings: - value: '1' newvalue: Unknown - value: '2' newvalue: Online - value: '3' newvalue: Failed - value: '4' newvalue: Degraded - uuid: 133b479d774847c2876cf8c19cedd191 name: Dell_PSU_SensorState mappings: - value: '1' newvalue: 'Presence Detected' - value: '2' newvalue: 'PS Failure' - value: '4' newvalue: 'Predictuve Failure' - value: '8' newvalue: 'PS AC lost' - value: '16' newvalue: 'AC lost or out of range' - value: '32' newvalue: 'AC out of range but still present' - value: '64' newvalue: 'Configuration Error'