5.02021-11-21T21:22:52ZTemplatesUNISIM_IPMI_Dell_PowerEdge_29003-IPMI Dell Power Edge 2900## Overview
IPMI sensors for Dell PowerEdge 2900:
Ambient Temp, FAN 1 RPM, FAN 2 RPM, FAN 3 RPM, FAN 4 RPM, FAN 5 RPM, FAN 6 RPM, Power
27/09/2016:
Some changes and fixes.
## Author
Daniel Carvalho
TemplatesFans SensorsPower SupplyTemperature Sensors- Ambient TempIPMIipmi.ambient.temp3007dFLOATCAmbient TempTemperature Sensors({TRIGGER.VALUE}=0 and {last(0)}<=3) or ({TRIGGER.VALUE}=1 and {last(0)}<=8)Ambient Temp temperature lower critical on {HOSTNAME}HIGH({TRIGGER.VALUE}=0 and {last(0)}<=8) or ({TRIGGER.VALUE}=1 and {last(0)}<=13)Ambient Temp temperature lower non-critical on {HOSTNAME}AVERAGE({TRIGGER.VALUE}=0 and {last(0)}>=47) or ({TRIGGER.VALUE}=1 and {last(0)}>=42)Ambient Temp temperature upper critical on {HOSTNAME}HIGH({TRIGGER.VALUE}=0 and {last(0)}>=42) or ({TRIGGER.VALUE}=1 and {last(0)}>=37)Ambient Temp temperature upper non-critical on {HOSTNAME}AVERAGE
- FAN 1 RPMIPMIipmi.fan.1.rpm3007dRPMFAN 1 RPMFans Sensors({TRIGGER.VALUE}=0 and {last(0)}<=1275) or ({TRIGGER.VALUE}=1 and {last(0)}<=1395)FAN 1 RPM lower critical on {HOSTNAME}HIGH
- FAN 2 RPMIPMIipmi.fan.2.rpm3007dRPMFAN 2 RPMFans Sensors({TRIGGER.VALUE}=0 and {last(0)}<=1275) or ({TRIGGER.VALUE}=1 and {last(0)}<=1395)FAN 2 RPM lower critical on {HOSTNAME}HIGH
- FAN 3 RPMIPMIipmi.fan.3.rpm3007dRPMFAN 3 RPMFans Sensors({TRIGGER.VALUE}=0 and {last(0)}<=1275) or ({TRIGGER.VALUE}=1 and {last(0)}<=1395)FAN 3 RPM lower critical on {HOSTNAME}HIGH
- FAN 4 RPMIPMIipmi.fan.4.rpm3007dRPMFAN 4 RPMFans Sensors({TRIGGER.VALUE}=0 and {last(0)}<=1275) or ({TRIGGER.VALUE}=1 and {last(0)}<=1395)FAN 4 RPM lower critical on {HOSTNAME}HIGH
- FAN 5 RPMIPMIipmi.fan.5.rpm3007dRPMFAN 5 RPMFans Sensors({TRIGGER.VALUE}=0 and {last(0)}<=1275) or ({TRIGGER.VALUE}=1 and {last(0)}<=1395)FAN 5 RPM lower critical on {HOSTNAME}HIGH
- FAN 6 RPMIPMIipmi.fan.6.rpm3007dRPMFAN 6 RPMFans Sensors({TRIGGER.VALUE}=0 and {last(0)}<=1275) or ({TRIGGER.VALUE}=1 and {last(0)}<=1395)FAN 6 RPM lower critical on {HOSTNAME}HIGH
- PowerIPMIpower3007dpowerPower SupplyService state{last(0)}=0Power status changed on {HOSTNAME}HIGH
Fan speed & temperature00C800- UNISIM_IPMI_Dell_PowerEdge_2900ipmi.fan.1.rpm
1C80000- UNISIM_IPMI_Dell_PowerEdge_2900ipmi.fan.2.rpm
20000C8RIGHT- UNISIM_IPMI_Dell_PowerEdge_2900ipmi.ambient.temp
Service state0Down1Up