5.02021-11-21T21:22:55ZTemplatesUNISIM_IPMI_Dell_PowerEdge_T3003-IPMI Dell Power Edge T300## Overview
IPMI sensors for Dell PowerEdge T300:
Ambient Temp, FAN 1 RPM, FAN 2 RPM, Planar Temp, Power
27/09/2016:
Some changes and fixes.
## Author
Daniel Carvalho
TemplatesFans SensorsPower SupplyTemperature Sensors- Ambient TempIPMIipmi.ambient.temp3007dFLOATCAmbient TempTemperature Sensors({TRIGGER.VALUE}=0 and {last(0)}<=3) or ({TRIGGER.VALUE}=1 and {last(0)}<=6)Ambient Temp temperature lower critical on {HOSTNAME}HIGH({TRIGGER.VALUE}=0 and {last(0)}<=6) or ({TRIGGER.VALUE}=1 and {last(0)}<=9)Ambient Temp temperature lower non-critical on {HOSTNAME}AVERAGE({TRIGGER.VALUE}=0 and {last(0)}>=47) or ({TRIGGER.VALUE}=1 and {last(0)}>=42)Ambient Temp temperature upper critical on {HOSTNAME}HIGH({TRIGGER.VALUE}=0 and {last(0)}>=42) or ({TRIGGER.VALUE}=1 and {last(0)}>=37)Ambient Temp temperature upper non-critical on {HOSTNAME}AVERAGE
- FAN 1 RPMIPMIipmi.fan.1.rpm3007dRPMFAN 1 RPMFans Sensors({TRIGGER.VALUE}=0 and {last(0)}<=1050) or ({TRIGGER.VALUE}=1 and {last(0)}<=1170)FAN 1 RPM lower critical on {HOSTNAME}HIGH
- FAN 2 RPMIPMIipmi.fan.2.rpm3007dRPMFAN 2 RPMFans Sensors({TRIGGER.VALUE}=0 and {last(0)}<=750) or ({TRIGGER.VALUE}=1 and {last(0)}<=870)FAN 2 RPM lower critical on {HOSTNAME}HIGH
- Planar TempIPMIipmi.planar.temp3007dFLOATCPlanar TempTemperature Sensors({TRIGGER.VALUE}=0 and {last(0)}<=3) or ({TRIGGER.VALUE}=1 and {last(0)}<=8)Planar Temp temperature lower critical on {HOSTNAME}HIGH({TRIGGER.VALUE}=0 and {last(0)}<=8) or ({TRIGGER.VALUE}=1 and {last(0)}<=13)Planar Temp temperature lower non-critical on {HOSTNAME}AVERAGE({TRIGGER.VALUE}=0 and {last(0)}>=58) or ({TRIGGER.VALUE}=1 and {last(0)}>=53)Planar Temp temperature upper critical on {HOSTNAME}HIGH({TRIGGER.VALUE}=0 and {last(0)}>=53) or ({TRIGGER.VALUE}=1 and {last(0)}>=48)Planar Temp temperature upper non-critical on {HOSTNAME}AVERAGE
- PowerIPMIpower3007dpowerPower SupplyService state{last(0)}=0Power status changed on {HOSTNAME}HIGH
Fan speed & temperature00C800- UNISIM_IPMI_Dell_PowerEdge_T300ipmi.fan.1.rpm
1C80000- UNISIM_IPMI_Dell_PowerEdge_T300ipmi.fan.2.rpm
20000C8RIGHT- UNISIM_IPMI_Dell_PowerEdge_T300ipmi.ambient.temp
3C800C8RIGHT- UNISIM_IPMI_Dell_PowerEdge_T300ipmi.planar.temp
Service state0Down1Up