zabbix_export: version: '5.4' date: '2021-11-21T21:23:00Z' groups: - uuid: 7df96b18c230490a9a0a9e2307226338 name: Templates templates: - uuid: 86f24ab819054e99999dd88df159d68f template: UNISIM_IPMI_Dell_PowerEdge_T320 name: '3-IPMI Dell Power Edge T320' description: | ## Overview IPMI sensors for Dell PowerEdge T320: Current 1, Current 2, Inlet Temp, Power, Pwr Consumption, Sys Fan1 RPM, Temp, Voltage 1, Voltage 2 27/09/2016: Some changes and fixes. ## Author Daniel Carvalho groups: - name: Templates items: - uuid: c98ff7a8b12a4d7b9d5bd6009d8f8be7 name: 'Current 1' type: IPMI key: ipmi.current.1 delay: '300' history: 7d value_type: FLOAT units: A ipmi_sensor: 'Current 1' tags: - tag: Application value: 'Current Sensors' - uuid: dd0d0b8d440942c7b16e6ac6dc37092f name: 'Current 2' type: IPMI key: ipmi.current.2 delay: '300' history: 7d value_type: FLOAT units: A ipmi_sensor: 'Current 2' tags: - tag: Application value: 'Current Sensors' - uuid: 884e0370ccac4065b290b3c37146e1c0 name: 'Inlet Temp' type: IPMI key: ipmi.inlet.temp delay: '300' history: 7d value_type: FLOAT units: C ipmi_sensor: 'Inlet Temp' tags: - tag: Application value: 'Temperature Sensors' triggers: - uuid: 4bee31a9ab5c487091e38eab4a3e6f54 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_Dell_PowerEdge_T320/ipmi.inlet.temp)<=-7) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_Dell_PowerEdge_T320/ipmi.inlet.temp)<=3)' name: 'Inlet Temp temperature lower critical on {HOSTNAME}' priority: HIGH - uuid: 834d2b093a364f9f9d1579f51095a7e7 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_Dell_PowerEdge_T320/ipmi.inlet.temp)<=3) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_Dell_PowerEdge_T320/ipmi.inlet.temp)<=13)' name: 'Inlet Temp temperature lower non-critical on {HOSTNAME}' priority: AVERAGE - uuid: ec39267814a14aa09f976e56846af516 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_Dell_PowerEdge_T320/ipmi.inlet.temp)>=47) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_Dell_PowerEdge_T320/ipmi.inlet.temp)>=42)' name: 'Inlet Temp temperature upper critical on {HOSTNAME}' priority: HIGH - uuid: a521fcbbb9a549dfb8ebb090f16b28d6 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_Dell_PowerEdge_T320/ipmi.inlet.temp)>=42) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_Dell_PowerEdge_T320/ipmi.inlet.temp)>=37)' name: 'Inlet Temp temperature upper non-critical on {HOSTNAME}' priority: AVERAGE - uuid: b22be6736799417f944c37b1748acf94 name: 'Pwr Consumption' type: IPMI key: ipmi.pwr.consumption delay: '300' history: 7d value_type: FLOAT units: W ipmi_sensor: 'Pwr Consumption' tags: - tag: Application value: 'Power Supply' triggers: - uuid: 94487e2e830d4d0bb647145f44b41d71 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_Dell_PowerEdge_T320/ipmi.pwr.consumption)>=1302) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_Dell_PowerEdge_T320/ipmi.pwr.consumption)>=1176)' name: 'Pwr Consumption watts upper critical on {HOSTNAME}' priority: HIGH - uuid: 31e83a21205d4bc38e065e20a6251b61 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_Dell_PowerEdge_T320/ipmi.pwr.consumption)>=1176) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_Dell_PowerEdge_T320/ipmi.pwr.consumption)>=1050)' name: 'Pwr Consumption watts upper non-critical on {HOSTNAME}' priority: AVERAGE - uuid: fb44b729ca2b43988e4505426cb5d162 name: 'Sys Fan1 RPM' type: IPMI key: ipmi.sys.fan1.rpm delay: '300' history: 7d units: RPM ipmi_sensor: 'Sys Fan1 RPM' tags: - tag: Application value: 'Fans Sensors' triggers: - uuid: c80d82f7476041c09da24f0c85d0b0f7 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_Dell_PowerEdge_T320/ipmi.sys.fan1.rpm)<=240) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_Dell_PowerEdge_T320/ipmi.sys.fan1.rpm)<=360)' name: 'Sys Fan1 RPM lower critical on {HOSTNAME}' priority: HIGH - uuid: 78eb5f56b9a84f1db4c0a9bfe4254c9f expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_Dell_PowerEdge_T320/ipmi.sys.fan1.rpm)<=360) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_Dell_PowerEdge_T320/ipmi.sys.fan1.rpm)<=480)' name: 'Sys Fan1 RPM lower non-critical on {HOSTNAME}' priority: AVERAGE - uuid: e6683d7260b74c32995bd5022f33c4cd name: Temp type: IPMI key: ipmi.temp delay: '300' history: 7d value_type: FLOAT units: C ipmi_sensor: Temp tags: - tag: Application value: 'Temperature Sensors' triggers: - uuid: 25c9797780a04605b92de3e90f188a76 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_Dell_PowerEdge_T320/ipmi.temp)<=3) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_Dell_PowerEdge_T320/ipmi.temp)<=8)' name: 'Temp temperature lower critical on {HOSTNAME}' priority: HIGH - uuid: b1fddee4a7e54ceab2bbf65d080da04f expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_Dell_PowerEdge_T320/ipmi.temp)<=8) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_Dell_PowerEdge_T320/ipmi.temp)<=13)' name: 'Temp temperature lower non-critical on {HOSTNAME}' priority: AVERAGE - uuid: c7e3c9ee386547489fd1718c2128174e expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_Dell_PowerEdge_T320/ipmi.temp)>=94) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_Dell_PowerEdge_T320/ipmi.temp)>=89)' name: 'Temp temperature upper critical on {HOSTNAME}' priority: HIGH - uuid: b8ae905a76ca4810af06f7d1303fc92b expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_Dell_PowerEdge_T320/ipmi.temp)>=89) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_Dell_PowerEdge_T320/ipmi.temp)>=85)' name: 'Temp temperature upper non-critical on {HOSTNAME}' priority: AVERAGE - uuid: 3eaf01f696f34190acc986610fd565f6 name: 'Voltage 1' type: IPMI key: ipmi.voltage.1 delay: '300' history: 7d value_type: FLOAT units: V ipmi_sensor: 'Voltage 1' tags: - tag: Application value: 'Voltage Sensors' - uuid: 188a06b0d90f4f678b95b3a105a698cd name: 'Voltage 2' type: IPMI key: ipmi.voltage.2 delay: '300' history: 7d value_type: FLOAT units: V ipmi_sensor: 'Voltage 2' tags: - tag: Application value: 'Voltage Sensors' - uuid: 119112a6424b4fe8b7485c99452fc60e name: Power type: IPMI key: power delay: '300' history: 7d ipmi_sensor: power valuemap: name: 'Service state' tags: - tag: Application value: 'Power Supply' triggers: - uuid: 4fd1f88b083d423a916df41ca26158ce expression: last(/UNISIM_IPMI_Dell_PowerEdge_T320/power)=0 name: 'Power status changed on {HOSTNAME}' priority: HIGH valuemaps: - uuid: 230ffd95ecaf4bffa0802ce72769238d name: 'Service state' mappings: - value: '0' newvalue: Down - value: '1' newvalue: Up graphs: - uuid: ed55a4780e074ee9acf4aa495bec8239 name: Consumption graph_items: - color: 00C800 item: host: UNISIM_IPMI_Dell_PowerEdge_T320 key: ipmi.pwr.consumption - uuid: 6e9a98a49eef4b3ba49d51ad787ca72e name: 'Fan speed & temperature' graph_items: - color: C80000 item: host: UNISIM_IPMI_Dell_PowerEdge_T320 key: ipmi.sys.fan1.rpm - sortorder: '1' color: 00C800 yaxisside: RIGHT item: host: UNISIM_IPMI_Dell_PowerEdge_T320 key: ipmi.inlet.temp - sortorder: '2' color: 0000C8 yaxisside: RIGHT item: host: UNISIM_IPMI_Dell_PowerEdge_T320 key: ipmi.temp - uuid: afdfeac3075648caa091f1ff70636b6f name: Power graph_items: - color: 0000C8 item: host: UNISIM_IPMI_Dell_PowerEdge_T320 key: ipmi.voltage.1 - sortorder: '1' color: C800C8 item: host: UNISIM_IPMI_Dell_PowerEdge_T320 key: ipmi.voltage.2 - sortorder: '2' color: 00C800 yaxisside: RIGHT item: host: UNISIM_IPMI_Dell_PowerEdge_T320 key: ipmi.current.1 - sortorder: '3' color: C80000 yaxisside: RIGHT item: host: UNISIM_IPMI_Dell_PowerEdge_T320 key: ipmi.current.2