zabbix_export: version: '6.0' date: '2021-11-21T21:23:04Z' groups: - uuid: 7df96b18c230490a9a0a9e2307226338 name: Templates templates: - uuid: ebcbaffe37bb43a4ba93635d02dce3ff template: UNISIM_IPMI_Dell_PowerEdge_T420 name: '3-IPMI Dell Power Edge T420' description: | ## Overview IPMI sensors for Dell PowerEdge T420: Current 1, Current 2, Inlet Temp, Power, Pwr Consumption, Sys Fan1 RPM, Temp, Voltage 1, Voltage 2 27/09/2016: Some changes and fixes. ## Author Daniel Carvalho groups: - name: Templates items: - uuid: 2dd915982daf4ba48afd47776027b816 name: 'Current 1' type: IPMI key: ipmi.current.1 delay: '300' history: 7d value_type: FLOAT units: A ipmi_sensor: 'Current 1' tags: - tag: Application value: 'Current Sensors' - uuid: f3360629b7ef49e9bdb383fccc799465 name: 'Current 2' type: IPMI key: ipmi.current.2 delay: '300' history: 7d value_type: FLOAT units: A ipmi_sensor: 'Current 2' tags: - tag: Application value: 'Current Sensors' - uuid: 3520039573cb48c3aa8bec9737c28270 name: 'Inlet Temp' type: IPMI key: ipmi.inlet.temp delay: '300' history: 7d value_type: FLOAT units: C ipmi_sensor: 'Inlet Temp' tags: - tag: Application value: 'Temperature Sensors' triggers: - uuid: 2d42c3cdd91e452b812a6f9dc50413ce expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_Dell_PowerEdge_T420/ipmi.inlet.temp)<=-7) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_Dell_PowerEdge_T420/ipmi.inlet.temp)<=3)' name: 'Inlet Temp temperature lower critical on {HOSTNAME}' priority: HIGH - uuid: ac867cddea5b4156824348d6b799ae36 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_Dell_PowerEdge_T420/ipmi.inlet.temp)<=3) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_Dell_PowerEdge_T420/ipmi.inlet.temp)<=13)' name: 'Inlet Temp temperature lower non-critical on {HOSTNAME}' priority: AVERAGE - uuid: 274104e79ab54f6d931df23ec220a3aa expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_Dell_PowerEdge_T420/ipmi.inlet.temp)>=47) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_Dell_PowerEdge_T420/ipmi.inlet.temp)>=42)' name: 'Inlet Temp temperature upper critical on {HOSTNAME}' priority: HIGH - uuid: 0d29a618d486446db53d140c2bb05b85 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_Dell_PowerEdge_T420/ipmi.inlet.temp)>=42) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_Dell_PowerEdge_T420/ipmi.inlet.temp)>=37)' name: 'Inlet Temp temperature upper non-critical on {HOSTNAME}' priority: AVERAGE - uuid: 1229ee26e0fd49509c891e9845316b26 name: 'Pwr Consumption' type: IPMI key: ipmi.pwr.consumption delay: '300' history: 7d value_type: FLOAT units: W ipmi_sensor: 'Pwr Consumption' tags: - tag: Application value: 'Power Supply' triggers: - uuid: fa779c10f9f441098a53db26c801c99e expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_Dell_PowerEdge_T420/ipmi.pwr.consumption)>=1974) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_Dell_PowerEdge_T420/ipmi.pwr.consumption)>=1792)' name: 'Pwr Consumption watts upper critical on {HOSTNAME}' priority: HIGH - uuid: 64047a4ba1664127995b7abd40c05bfa expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_Dell_PowerEdge_T420/ipmi.pwr.consumption)>=1792) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_Dell_PowerEdge_T420/ipmi.pwr.consumption)>=1610)' name: 'Pwr Consumption watts upper non-critical on {HOSTNAME}' priority: AVERAGE - uuid: b59b84565c6e43e0bea2ed74b7fc4dec name: 'Sys Fan1 RPM' type: IPMI key: ipmi.sys.fan1.rpm delay: '300' history: 7d units: RPM ipmi_sensor: 'Sys Fan1 RPM' tags: - tag: Application value: 'Fans Sensors' triggers: - uuid: 334b749e21184b028918b130d217f84b expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_Dell_PowerEdge_T420/ipmi.sys.fan1.rpm)<=240) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_Dell_PowerEdge_T420/ipmi.sys.fan1.rpm)<=360)' name: 'Sys Fan1 RPM lower critical on {HOSTNAME}' priority: HIGH - uuid: e5622b1ccaa94cc2b23968fb4caf0959 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_Dell_PowerEdge_T420/ipmi.sys.fan1.rpm)<=360) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_Dell_PowerEdge_T420/ipmi.sys.fan1.rpm)<=480)' name: 'Sys Fan1 RPM lower non-critical on {HOSTNAME}' priority: AVERAGE - uuid: fa35a223cdcf49b49b772e480922fda7 name: Temp type: IPMI key: ipmi.temp delay: '300' history: 7d value_type: FLOAT units: C ipmi_sensor: Temp tags: - tag: Application value: 'Temperature Sensors' triggers: - uuid: fc21ee1a108f4bd9a52b94225b676c08 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_Dell_PowerEdge_T420/ipmi.temp)<=3) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_Dell_PowerEdge_T420/ipmi.temp)<=8)' name: 'Temp temperature lower critical on {HOSTNAME}' priority: HIGH - uuid: 992e7c7ceac04fe58e8cbeedd6452192 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_Dell_PowerEdge_T420/ipmi.temp)<=8) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_Dell_PowerEdge_T420/ipmi.temp)<=13)' name: 'Temp temperature lower non-critical on {HOSTNAME}' priority: AVERAGE - uuid: b3a41c1edb624b0eb539ad843df9ad3d expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_Dell_PowerEdge_T420/ipmi.temp)>=94) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_Dell_PowerEdge_T420/ipmi.temp)>=89)' name: 'Temp temperature upper critical on {HOSTNAME}' priority: HIGH - uuid: 1d21fe7186ba4fc4981eaf1cd742b101 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_Dell_PowerEdge_T420/ipmi.temp)>=89) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_Dell_PowerEdge_T420/ipmi.temp)>=85)' name: 'Temp temperature upper non-critical on {HOSTNAME}' priority: AVERAGE - uuid: 0c1146c24d714a16b62111f015928394 name: 'Voltage 1' type: IPMI key: ipmi.voltage.1 delay: '300' history: 7d value_type: FLOAT units: V ipmi_sensor: 'Voltage 1' tags: - tag: Application value: 'Voltage Sensors' - uuid: 799ee83328514050a95b64506e9c52ec name: 'Voltage 2' type: IPMI key: ipmi.voltage.2 delay: '300' history: 7d value_type: FLOAT units: V ipmi_sensor: 'Voltage 2' tags: - tag: Application value: 'Voltage Sensors' - uuid: 6895d3ea14614296bc3dd986f31b3d6c name: Power type: IPMI key: power delay: '300' history: 7d ipmi_sensor: power valuemap: name: 'Service state' tags: - tag: Application value: 'Power Supply' triggers: - uuid: a38eeba986ef45968fc2341583b0f720 expression: last(/UNISIM_IPMI_Dell_PowerEdge_T420/power)=0 name: 'Power status changed on {HOSTNAME}' priority: HIGH valuemaps: - uuid: 73476ff923a74b15a1aa7c38502976f5 name: 'Service state' mappings: - value: '0' newvalue: Down - value: '1' newvalue: Up graphs: - uuid: 4b656596a70c444d95390d3dace3a1cb name: Consumption graph_items: - color: 00C800 item: host: UNISIM_IPMI_Dell_PowerEdge_T420 key: ipmi.pwr.consumption - uuid: c6bac5aa56b0433e83d26f2ce88e550f name: 'Fan speed & temperature' graph_items: - color: C80000 item: host: UNISIM_IPMI_Dell_PowerEdge_T420 key: ipmi.sys.fan1.rpm - sortorder: '1' color: 00C800 yaxisside: RIGHT item: host: UNISIM_IPMI_Dell_PowerEdge_T420 key: ipmi.inlet.temp - sortorder: '2' color: 0000C8 yaxisside: RIGHT item: host: UNISIM_IPMI_Dell_PowerEdge_T420 key: ipmi.temp - uuid: 7729748a92184b7aad0e4d40e37b4d7e name: Power graph_items: - color: 0000C8 item: host: UNISIM_IPMI_Dell_PowerEdge_T420 key: ipmi.voltage.1 - sortorder: '1' color: C800C8 item: host: UNISIM_IPMI_Dell_PowerEdge_T420 key: ipmi.voltage.2 - sortorder: '2' color: 00C800 yaxisside: RIGHT item: host: UNISIM_IPMI_Dell_PowerEdge_T420 key: ipmi.current.1 - sortorder: '3' color: C80000 yaxisside: RIGHT item: host: UNISIM_IPMI_Dell_PowerEdge_T420 key: ipmi.current.2