5.02021-11-21T21:23:05ZTemplatesUNISIM_IPMI_Dell_PowerEdge_T6203-IPMI Dell Power Edge T620## Overview
IPMI sensors for Dell PowerEdge T620:
Current 1, Current 2, Fan1 RPM, Fan2 RPM, Inlet Temp, Power, Pwr Consumption, Voltage 1, Voltage 2, Temp
27/09/2016:
Some changes and fixes.
Add Temp Sensor.
## Author
Daniel Carvalho
TemplatesCurrent SensorsFans SensorsPower SupplyTemperature SensorsVoltage Sensors- Current 1IPMIipmi.current.13007dFLOATACurrent 1Current Sensors
- Current 2IPMIipmi.current.23007dFLOATACurrent 2Current Sensors
- Fan1 RPMIPMIipmi.fan1.rpm3007dRPMFan1 RPMFans Sensors({TRIGGER.VALUE}=0 and {last(0)}<=360) or ({TRIGGER.VALUE}=1 and {last(0)}<=480)Fan1 RPM lower critical on {HOSTNAME}HIGH({TRIGGER.VALUE}=0 and {last(0)}<=480) or ({TRIGGER.VALUE}=1 and {last(0)}<=600)Fan1 RPM lower non-critical on {HOSTNAME}AVERAGE
- Fan2 RPMIPMIipmi.fan2.rpm3007dRPMFan2 RPMFans Sensors({TRIGGER.VALUE}=0 and {last(0)}<=360) or ({TRIGGER.VALUE}=1 and {last(0)}<=480)Fan2 RPM lower critical on {HOSTNAME}HIGH({TRIGGER.VALUE}=0 and {last(0)}<=480) or ({TRIGGER.VALUE}=1 and {last(0)}<=600)Fan2 RPM lower non-critical on {HOSTNAME}AVERAGE
- Inlet TempIPMIipmi.inlet.temp3007dFLOATCInlet TempTemperature Sensors({TRIGGER.VALUE}=0 and {last(0)}<=-6) or ({TRIGGER.VALUE}=1 and {last(0)}<=4)Inlet Temp temperature lower critical on {HOSTNAME}HIGH({TRIGGER.VALUE}=0 and {last(0)}<=4) or ({TRIGGER.VALUE}=1 and {last(0)}<=12)Inlet Temp temperature lower non-critical on {HOSTNAME}AVERAGE({TRIGGER.VALUE}=0 and {last(0)}>=48) or ({TRIGGER.VALUE}=1 and {last(0)}>=43)Inlet Temp temperature upper critical on {HOSTNAME}HIGH({TRIGGER.VALUE}=0 and {last(0)}>=43) or ({TRIGGER.VALUE}=1 and {last(0)}>=35)Inlet Temp temperature upper non-critical on {HOSTNAME}AVERAGE
- Pwr ConsumptionIPMIipmi.pwr.consumption3007dFLOATWPwr ConsumptionPower Supply({TRIGGER.VALUE}=0 and {last(0)}>=1344) or ({TRIGGER.VALUE}=1 and {last(0)}>=1232)Pwr Consumption watts upper critical on {HOSTNAME}HIGH({TRIGGER.VALUE}=0 and {last(0)}>=1232) or ({TRIGGER.VALUE}=1 and {last(0)}>=1200)Pwr Consumption watts upper non-critical on {HOSTNAME}AVERAGE
- TempIPMIipmi.temp3007dFLOATCTempTemperature Sensors({TRIGGER.VALUE}=0 and {last(0)}<=3) or ({TRIGGER.VALUE}=1 and {last(0)}<=8)Temp temperature lower critical on {HOSTNAME}HIGH({TRIGGER.VALUE}=0 and {last(0)}<=8) or ({TRIGGER.VALUE}=1 and {last(0)}<=13)Temp temperature lower non-critical on {HOSTNAME}AVERAGE({TRIGGER.VALUE}=0 and {last(0)}>=88) or ({TRIGGER.VALUE}=1 and {last(0)}>=83)Temp temperature upper critical on {HOSTNAME}HIGH({TRIGGER.VALUE}=0 and {last(0)}>=83) or ({TRIGGER.VALUE}=1 and {last(0)}>=78)Temp temperature upper non-critical on {HOSTNAME}AVERAGE
- Voltage 1IPMIipmi.voltage.13007dFLOATVVoltage 1Voltage Sensors
- Voltage 2IPMIipmi.voltage.23007dFLOATVVoltage 2Voltage Sensors
- PowerIPMIpower3007dpowerPower SupplyService state{last(0)}=0Power status changed on {HOSTNAME}HIGH
Consumption00C800- UNISIM_IPMI_Dell_PowerEdge_T620ipmi.pwr.consumption
Fan speed & temperatureC80000- UNISIM_IPMI_Dell_PowerEdge_T620ipmi.fan1.rpm
100C800RIGHT- UNISIM_IPMI_Dell_PowerEdge_T620ipmi.inlet.temp
Power0000C8- UNISIM_IPMI_Dell_PowerEdge_T620ipmi.voltage.1
1C800C8- UNISIM_IPMI_Dell_PowerEdge_T620ipmi.voltage.2
200C800RIGHT- UNISIM_IPMI_Dell_PowerEdge_T620ipmi.current.1
3C80000RIGHT- UNISIM_IPMI_Dell_PowerEdge_T620ipmi.current.2
Service state0Down1Up