5.02021-11-21T21:52:35ZTemplates HardwareIPMI HP DL380p Gen9 without DrivesIPMI HP DL380p Gen9 without Drives## Overview
Simple template to monitor ipmi hp DL380p G9 server by ipmi protocol by iLO interface.
useful with [my hp ipmi Drives discovery template](cat-server-hardware/hp/ipmi-hp-servers-hdd-discovery)
Please first corretly configure ipmi interface on node in zabbix web interface.
This pack contains template: IPMI HP DL380p Gen9 without Drives.xml - contains all sensors except hard drives I prefer use template with noHDD option and my ipmi HDD discovery template.
## Author
Dmitry Lavrukhin
Templates HardwareFanHardwareHealthMemoryPowerTemp- 01-Inlet AmbientIPMI01-InletAmbient36007dFLOATC01-Inlet AmbientHardwareTemp{last()}>42Inlet Temperature is High!HIGH
- 02-CPU 1IPMI02-CPU136007dFLOAT?02-CPU 1HardwareTemp
- 03-CPU 2IPMI03-CPU236007dFLOAT?03-CPU 2HardwareTemp
- 08-HD MaxIPMI08-HDMax36007dFLOATC08-HD MaxHardwareTemp{last()}>60HD Temp very High!HIGH
- 10-ChipsetIPMI10-Chipset36007dFLOATC10-ChipsetHardwareTemp{last()}>104Chipset Temp is very High!HIGH
- 40-Battery ZoneIPMI40-BatteryZone36007dFLOATC40-Battery ZoneHardwareTemp{last()}>75Battery zone Temp is very High!HIGH
- Fan 1IPMIFan136007dFLOATFan 1FanHardwareServer HP Fan
- Fan 2IPMIFan236007dFLOATFan 2FanHardwareServer HP Fan
- Fan 3IPMIFan336007dFLOATFan 3FanHardwareServer HP Fan
- Fan 4IPMIFan436007dFLOATFan 4FanHardwareServer HP Fan
- Fan 5IPMIFan536007dFLOATFan 5FanHardwareServer HP Fan
- Fan 6IPMIFan636007dFLOATFan 6FanHardwareServer HP Fan
- FansIPMIFans36007dFansHardwareHealthServer HP Fan{last()}<>1Fans not Fully redundantHIGH
- Megacell StatusIPMIMegacellStatus36007dMegacell StatusHardwareHealthServer HP Health{last()}<>4Megacell Status Battery Errorhttps://{$ILO_IP}HIGHplease check Battry state at ilo
- Memory StatusIPMIMemoryStatus36007dMemory StatusHardwareHealthServer HP Health{last()}<>64Memory status errorhttps://{$ILO_IP}HIGHplease check memory state at ilo
- Power Supply 1IPMIPowerSupply136007dFLOATPower Supply 1HardwarePower
- Power Supply 2IPMIPowerSupply236007dFLOATPower Supply 2HardwarePower
- PwrMeter OutputIPMIPwrMeterOutput36007dFLOATWattsPwrMeter OutputHardwarePower
- Sys Health LEDIPMISysHealthLED36007dSys Health LEDHardwareHealthServer HP Fan{last()}<>1Error Sys. Health LEDHIGH
- UIDIPMIUID36007dUIDHardwareHealthServer HP Health{nodata(10800)}=13h with No data from IPMI interfaceHIGH
{IPMI HP DL380p Gen9 without Drives:PowerSupply1.last()}<>1 or {IPMI HP DL380p Gen9 without Drives:PowerSupply2.last()}<>1Error PowerHIGH{IPMI HP DL380p Gen9 without Drives:02-CPU1.last()}>70 or {IPMI HP DL380p Gen9 without Drives:03-CPU2.last()}>70Error Temp CPUHIGHCPUFIXED0000EE- IPMI HP DL380p Gen9 without Drives02-CPU1
100C800- IPMI HP DL380p Gen9 without Drives03-CPU2
PwrMeterOutput1A7C11- IPMI HP DL380p Gen9 without DrivesPwrMeterOutput
Server HP Fan0Failure1OKServer HP Health0OK1Error