zabbix_export: version: '6.0' date: '2021-11-21T21:23:24Z' groups: - uuid: 7df96b18c230490a9a0a9e2307226338 name: Templates templates: - uuid: d3a2af68a4cb440dbe72eafb436fa2bc template: 'IPMI Intel RMM3' name: 'IPMI Intel RMM3' description: | ## Overview IntelĀ® Remote Management Module 3 Sensors: * 1 | BB +1.05V PCH | Voltage * 2 | BB +1.1V P1 Vccp | Voltage * 3 | BB +1.5V P1 DDR3 | Voltage * 4 | BB +3.3V | Voltage * 5 | BB +3.3V STBY | Voltage * 6 | BB +5.0V | Voltage * 7 | Baseboard Temp1 | Temperature * 8 | Baseboard Temp2 | Temperature * 9 | Front Panel Temp | Temperature * 11 | Sys Fan Tach 1A | Fan * 12 | Sys Fan Tach 1B | Fan * 13 | Sys Fan Tach 2A | Fan * 14 | Sys Fan Tach 2B | Fan * 15 | Sys Fan Tach 3A | Fan * 16 | Sys Fan Tach 3B | Fan * 17 | PS Power In | Other Units Based Sensor 4 Triggers note: Authentication algorithm - md5 groups: - name: Templates items: - uuid: a7327e3471c448e9a1c9f1d4d37c3180 name: 'Baseboard Temp1' type: IPMI key: rmm3.Baseboard_Temp1 delay: '30' units: C ipmi_sensor: 'Baseboard Temp1' tags: - tag: Application value: 'IPMI Sensors' - tag: Application value: Temperature triggers: - uuid: eb5c0b19d4514e779182538772163de2 expression: 'last(/IPMI Intel RMM3/rmm3.Baseboard_Temp1)<9 or last(/IPMI Intel RMM3/rmm3.Baseboard_Temp1)>60' name: 'Baseboard Temp1 [{ITEM.VALUE}]' priority: HIGH - uuid: 8578f8443c1a46efa443c2d5eee198c8 name: 'Baseboard Temp2' type: IPMI key: rmm3.Baseboard_Temp2 delay: '30' units: C ipmi_sensor: 'Baseboard Temp2' tags: - tag: Application value: 'IPMI Sensors' - tag: Application value: Temperature triggers: - uuid: e5f6ac92871b4dd2861017b0f152a4dd expression: | last(/IPMI Intel RMM3/rmm3.Baseboard_Temp2)<9 or last(/IPMI Intel RMM3/rmm3.Baseboard_Temp2)>60 name: 'Baseboard Temp2 [{ITEM.VALUE}]' priority: HIGH - uuid: 8843fdb170064f74a98c38b6e7206c8d name: 'BB +1.05V PCH' type: IPMI key: rmm3.BB_plus1.05V_PCH delay: '30' value_type: FLOAT units: V ipmi_sensor: 'BB +1.05V PCH' tags: - tag: Application value: 'IPMI Sensors' - tag: Application value: Voltage - uuid: 671d362df5334961aae6df2e777ef586 name: 'BB +1.1V P1 Vccp' type: IPMI key: rmm3.BB_plus1.1V_P1_Vccp delay: '30' value_type: FLOAT units: V ipmi_sensor: 'BB +1.1V P1 Vccp' tags: - tag: Application value: 'IPMI Sensors' - tag: Application value: Voltage - uuid: 981bec1846fa4f12804b7a80f88d344d name: 'BB +1.5V P1 DDR3' type: IPMI key: rmm3.BB_plus1.5V_P1_DDR3 delay: '30' value_type: FLOAT units: V ipmi_sensor: 'BB +1.5V P1 DDR3' tags: - tag: Application value: 'IPMI Sensors' - tag: Application value: Voltage - uuid: 72b467ad83ca4f0fab1205f2bba8f089 name: 'BB +3.3V' type: IPMI key: rmm3.BB_plus3.3V delay: '30' value_type: FLOAT units: V ipmi_sensor: 'BB +3.3V' tags: - tag: Application value: 'IPMI Sensors' - tag: Application value: Voltage - uuid: b4abd5c3c76d4774bd35a67a90a7eef9 name: 'BB +3.3V STBY' type: IPMI key: rmm3.BB_plus3.3V_STBY delay: '30' value_type: FLOAT units: V ipmi_sensor: 'BB +3.3V STBY' tags: - tag: Application value: 'IPMI Sensors' - tag: Application value: Voltage - uuid: 7dd21e2bedb74363980a576f67c40d5a name: 'BB +5.0V' type: IPMI key: rmm3.B_plus5.0V delay: '30' value_type: FLOAT units: V ipmi_sensor: 'BB +5.0V' tags: - tag: Application value: 'IPMI Sensors' - tag: Application value: Voltage - uuid: 0bb80f8bc4854e939a846830018a190e name: 'Front Panel Temp' type: IPMI key: rmm3.Front_Panel_Temp delay: '30' units: C ipmi_sensor: 'Front Panel Temp' tags: - tag: Application value: 'IPMI Sensors' - tag: Application value: Temperature - uuid: 47e418542d5e4eb8a5b5a7aa1cb1f6e1 name: 'PS Power In' type: IPMI key: rmm3.PS_Power_In delay: '30' units: W ipmi_sensor: 'PS Power In' tags: - tag: Application value: 'IPMI Sensors' - tag: Application value: Power triggers: - uuid: 69199c41afdb4325a8eeb7b301b98f5b expression: 'last(/IPMI Intel RMM3/rmm3.PS_Power_In)=0' name: 'Power is off on {HOST.NAME}' priority: AVERAGE - uuid: 7bae63c9a64f45509e17fefcdd94197a name: 'Sys Fan Tach 1A' type: IPMI key: rmm3.Sys_Fan_Tach_1A delay: '30' units: RPM ipmi_sensor: 'Sys Fan Tach 1A' tags: - tag: Application value: Fan - tag: Application value: 'IPMI Sensors' - uuid: 19b785866057487198c90c015668cbaf name: 'Sys Fan Tach 1B' type: IPMI key: rmm3.Sys_Fan_Tach_1B delay: '30' units: RPM ipmi_sensor: 'Sys Fan Tach 1B' tags: - tag: Application value: Fan - tag: Application value: 'IPMI Sensors' - uuid: 05766a640574472fa959e27266d82c9c name: 'Sys Fan Tach 2A' type: IPMI key: rmm3.Sys_Fan_Tach_2A delay: '30' units: RPM ipmi_sensor: 'Sys Fan Tach 2A' tags: - tag: Application value: Fan - tag: Application value: 'IPMI Sensors' - uuid: 031334288dcc47ea8d827e830e668650 name: 'Sys Fan Tach 2B' type: IPMI key: rmm3.Sys_Fan_Tach_2B delay: '30' units: RPM ipmi_sensor: 'Sys Fan Tach 2B' tags: - tag: Application value: Fan - tag: Application value: 'IPMI Sensors' - uuid: 712d47885dd04ba0bb3375ecd4bf6519 name: 'Sys Fan Tach 3A' type: IPMI key: rmm3.Sys_Fan_Tach_3A delay: '30' units: RPM ipmi_sensor: 'Sys Fan Tach 3A' tags: - tag: Application value: Fan - tag: Application value: 'IPMI Sensors' - uuid: 8b28180695874903b1a4776ba765d320 name: 'Sys Fan Tach 3B' type: IPMI key: rmm3.Sys_Fan_Tach_3B delay: '30' units: RPM ipmi_sensor: 'Sys Fan Tach 3B' tags: - tag: Application value: Fan - tag: Application value: 'IPMI Sensors' triggers: - uuid: f434c0b30ecc414ea9070c9a5eadd04e expression: | last(/IPMI Intel RMM3/rmm3.Sys_Fan_Tach_1A)<1000 or last(/IPMI Intel RMM3/rmm3.Sys_Fan_Tach_1B)<1000 or last(/IPMI Intel RMM3/rmm3.Sys_Fan_Tach_2A)<1000 or last(/IPMI Intel RMM3/rmm3.Sys_Fan_Tach_2B)<1000 or last(/IPMI Intel RMM3/rmm3.Sys_Fan_Tach_3A)<1000 or last(/IPMI Intel RMM3/rmm3.Sys_Fan_Tach_3B)<1000 name: 'Low fan speed on {HOST.NAME}' priority: WARNING