5.02021-11-21T21:26:06ZTemplatesSNMP MegaRAID SASSNMP MegaRAID SAS## Description
Zabbix Template for Avago Megaraid SAS (formerly LSI) RAID cards
## Overview
This is initial template for Monitoring LSI/Avago/Broadcom (or branded like Intel, IBM, Supermicro etc) MegaRAID based hardware RAID cards. According to vendor docs it should also support non-RAID adapters, enclosures and some other devices.
It took me one night to complete major/required parts, so far template supports most of the options and all the critical components to keep you warned in case some RAID-related problems will occur.
Supported so far:
* Full LLD Support
* Informational part for agent/driver/module
* Complete Adapter-Related OID list with graphs and triggers
* Part of Device-Related OID's with graphs
* All triggers that are crucial
* Comments for all OID's with value mappings from MegaRAID MIB
Planned:
* Value Mappings
* Completing list of device OID's and related graphs
* virtualDevice OID's and related graphs
* enclosureInfo OID's and related graphs
* Trap setting OID's
* Traps for trapper
* Check for updated version
Not tested yet:
* M$ Windows Support
* Values and units are done as per MIB doc with 1-1 match, cannot guarantee that they are correct if vendor has provided wrong info (apparently, there is at least one minor issue)
Installation and Requirements:
* Ensure, that LSI-MegaRAID-SAS-MIB files downloaded from vendor site are installed and added to snmp.conf (after that you can restart both agent and server)
* Ensure, that appropriate package (snmp sas or snmp sas\_ir) with MegaRAID snmp agent wrapper is installed and running, snmpd.conf for OID's are set as per doc for wrapper
* Ensure, that Zabbix is allowed to gather information from snmpd
* Ensure, that required device drivers are installed on the hosts
* Import Template, assign to hosts
* Wait for LLD to check all OID's and start gathering data
* Have a good night's sleep
Bugs?
-> Please Report @GitHub or at giomac gmail com
When will you finish this?
-> Nah, all critical issues are included, will do, definitely, but not asap
## Author
George Machitidze
Templates- MegaRAID SAS MIB Number of SAS adapters presentSNMP_AGENTLSI-MegaRAID-SAS-MIB::adpNumber.0adpNumber6030d{last()}=0No MegaRAID adapters present on hostHIGH
- MegaRAID SAS MIB Agent Module NameSNMP_AGENTLSI-MegaRAID-SAS-MIB::agentModuleName.0agentModuleName60365d0TEXT
- MegaRAID SAS MIB Agent Module VersionSNMP_AGENTLSI-MegaRAID-SAS-MIB::agentModuleVersion.0agentModuleVersion60365d0TEXT{nodata(5m)}=1No SNMP data available for MegaRAID devices for 5 minHIGH
- MegaRAID SAS MIB VersionSNMP_AGENTLSI-MegaRAID-SAS-MIB::mibVersion.0mibVersion60365d0TEXT
MegaRAID SAS MIB SAS adaptersSNMP_AGENTdiscovery[{#SNMPVALUE},LSI-MegaRAID-SAS-MIB::adapterID]adapterID900A List of adapter Entries containing Information/Properties about the MegaRAID related adapters on host.MegaRAID SAS MIB Abort CC on detecting error support for adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::abortCConErrorSupported.{#SNMPINDEX}abortCConErrorSupported[{#SNMPVALUE}]6030dAbort CC on detecting error is supported on this adapter.
Values:No(0),Yes(1)BOOL_TO_DECIMALMegaRAID SAS MIB Abort Consistency Check on error Adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::abortCConError.{#SNMPINDEX}abortCConError[{#SNMPVALUE}]6030dAbort CC on detecting error is enabled or disabled on this adapter.
Values:No(0),Yes(1),NA(2)MegaRAID SAS MIB Adapter $1 PCI Vendor IDSNMP_AGENTLSI-MegaRAID-SAS-MIB::adapterVendorID.{#SNMPINDEX}adapterVendorID[{#SNMPVALUE}]6030d0TEXTPCI Vendor ID for this Adapter.MegaRAID SAS MIB Alarm Control Support for adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::alarmControlSupported.{#SNMPINDEX}alarmControlSupported[{#SNMPVALUE}]6030dAlarm control support for this adapter. Values:false(0),true(1)BOOL_TO_DECIMALMegaRAID SAS MIB Alarm State on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::alarmState.{#SNMPINDEX}alarmState[{#SNMPVALUE}]6030dAlarm is enabled or disabled on this adapter. Values:disabled(0),enabled(1)BOOL_TO_DECIMALMegaRAID SAS MIB Controller encryption support on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::allowCtrlEncryption.{#SNMPINDEX}allowCtrlEncryption[{#SNMPVALUE}]6030dif it is set (1) supports controller encryptionMegaRAID SAS MIB Mixer Redundancy Support for adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::allowMixedRedundancyOnArraySupported.{#SNMPINDEX}allowMixedRedundancyOnArraySupported[{#SNMPVALUE}]6030dAllow different Virtual Disk on the same array to have different redundancy levels.
Values:false(0),true(1)BOOL_TO_DECIMALMegaRAID SAS MIB Mix in Enclosure Support on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::allowMixInEnclosure.{#SNMPINDEX}allowMixInEnclosure[{#SNMPVALUE}]6030dMix InEnclosure support. Values:notSupported(0), supported(1)MegaRAID SAS MIB Mix in Virtual Drive Support on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::allowMixInVD.{#SNMPINDEX}allowMixInVD[{#SNMPVALUE}]6030dMixInVIRTUALDRIVE support. Values:notSupported(0), supported(1)MegaRAID SAS MIB Allow SSD/HDD Mix within LD on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::allowMixSSDHDDInLD.{#SNMPINDEX}allowMixSSDHDDInLD[{#SNMPVALUE}]6030dallow SSD/HDD mix within an LD.allow(1), not allow(0)BOOL_TO_DECIMALMegaRAID SAS MIB SATA in Cluster Support on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::allowSataInCluster.{#SNMPINDEX}allowSataInCluster[{#SNMPVALUE}]6030dSataInCluster support. Values:notSupported(0), supported(1)MegaRAID SAS MIB Allow SAS/SATA SSD within LD on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::allowSSDMixInLD.{#SNMPINDEX}allowSSDMixInLD[{#SNMPVALUE}]6030dallow SAS/SATA SSD mix within an LD. allow(1), not allow(0)BOOL_TO_DECIMALMegaRAID SAS MIB Battery Backup Unit Support for adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::bbuSupported.{#SNMPINDEX}bbuSupported[{#SNMPVALUE}]6030dBBU support for this adapter. Values:false(0),true(1)BOOL_TO_DECIMALMegaRAID SAS MIB Background Initialization Rate Change Support for adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::bgiRateSupported.{#SNMPINDEX}bgiRateSupported[{#SNMPVALUE}]6030dBackground initialization rate change support for this adapter. Values:false(0),true(1)BOOL_TO_DECIMALMegaRAID SAS MIB Background Initialization Rate on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::bgiRate.{#SNMPINDEX}bgiRate[{#SNMPVALUE}]6030d%Background initialization rate for this adapter.MegaRAID SAS MIB BIOS Not Detected Support on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::biosNotDetected.{#SNMPINDEX}biosNotDetected[{#SNMPVALUE}]6030dbios Not Detected support for this Adapter. Values:false(0),true(1)MegaRAID SAS MIB Cache Flush Interval on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::cacheFlushInterval.{#SNMPINDEX}cacheFlushInterval[{#SNMPVALUE}]6030dsCache flush interval in seconds for this adapter.MegaRAID SAS MIB Controller Cache pinned for missing or offline LDs on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::cacheIsPinned.{#SNMPINDEX}cacheIsPinned[{#SNMPVALUE}]6030d1=controller cache is pinned for missing or offline LDsMegaRAID SAS MIB Consistensy Check Rate Change Support for adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::ccRateSupported.{#SNMPINDEX}ccRateSupported[{#SNMPVALUE}]6030dConsistency Check rate change support for this Adapter. Values:false(0),true(1)BOOL_TO_DECIMALMegaRAID SAS MIB Consistency Check Rate on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::ccRate.{#SNMPINDEX}ccRate[{#SNMPVALUE}]6030d%Consistency Check rate on this Adapter.MegaRAID SAS MIB Cluster State on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::clusterState.{#SNMPINDEX}clusterState[{#SNMPVALUE}]6030dCluster is enabled or disabled on this adapter. Values:disabled(0),enabled(1)BOOL_TO_DECIMALMegaRAID SAS MIB Cluster Support for adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::clusterSupported.{#SNMPINDEX}clusterSupported[{#SNMPVALUE}]6030dCluster support for this adapter. Values:false(0),true(1)BOOL_TO_DECIMALMegaRAID SAS MIB Drive Capacity Coercion Mode on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::coercionMode.{#SNMPINDEX}coercionMode[{#SNMPVALUE}]6030dDrive capacity coercion mode. 0->None;1->128MB;2->1GBMegaRAID SAS MIB Compatibility for adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::compatibilityFlag.{#SNMPINDEX}compatibilityFlag[{#SNMPVALUE}]6030dTo inform compatibilities between Applications and FW. 0->incompatible;1->compatibleBOOL_TO_DECIMALMegaRAID SAS MIB Compatibility info for adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::compatibilityInfo.{#SNMPINDEX}compatibilityInfo[{#SNMPVALUE}]6030d0TEXTCompatibility Information. Format->(Firmware Forward compatibility flag:Firmware Backward compatibility flag:Firmware version flag:Application Forward compatibility flag:Application Backward compatibility flag:Application version flag)MegaRAID SAS MIB CopyBack state on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::copyBackState.{#SNMPINDEX}copyBackState[{#SNMPVALUE}]6030dCopyBack is enabled or disabled on this adapter.Values:disabled(0),enabled(1)MegaRAID SAS MIB Controller SAS Addresses on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::ctrlSasAddr.{#SNMPINDEX}ctrlSasAddr[{#SNMPVALUE}]6030d0TEXTThis field gives the controller SAS addressMegaRAID SAS MIB Dedicated Hotspares Support for adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::dedicatedHotSparesSupported.{#SNMPINDEX}dedicatedHotSparesSupported[{#SNMPVALUE}]6030dDedicated HotSpares support for this adapter. Values:false(0),true(1)BOOL_TO_DECIMALMegaRAID SAS MIB adapter $1 default power saving policySNMP_AGENTLSI-MegaRAID-SAS-MIB::defaultLdPSPolicy.{#SNMPINDEX}defaultLdPSPolicy[{#SNMPVALUE}]6030dpower saving policy.values:controller default power saving policy=0, AUTO=1, MAX=2, Max with no cache=6, NONE=255MegaRAID SAS MIB Adapter $1 PCI Device IDSNMP_AGENTLSI-MegaRAID-SAS-MIB::devID.{#SNMPINDEX}devID[{#SNMPVALUE}]6030d0TEXTPCI Device ID for this Adapter.MegaRAID SAS MIB Device Interface Port Addresses on Adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::devInterfacePortAddr.{#SNMPINDEX}devInterfacePortAddr[{#SNMPVALUE}]6030d0TEXTDevice Port address comma delimitedMegaRAID SAS MIB Device Interface Port Count on Adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::devInterfacePortCnt.{#SNMPINDEX}devInterfacePortCnt[{#SNMPVALUE}]6030dDevice Port Count on this adapter.MegaRAID SAS MIB Multiple Device Interface Support Values for Adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::devInterface.{#SNMPINDEX}devInterface[{#SNMPVALUE}]6030d0TEXTMultiple device interface support values separated by space.MegaRAID SAS MIB Large IO Support on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::disableLargeIO.{#SNMPINDEX}disableLargeIO[{#SNMPVALUE}]6030d0=Large IO is supported, 1=Large IO is unsupportedMegaRAID SAS MIB Interval for disabling power saving after power saving time on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::disableLdPSInterval.{#SNMPINDEX}disableLdPSInterval[{#SNMPVALUE}]6030dhLD power savings are disabled for yy hours beginning at disableLdPSTime.MegaRAID SAS MIB Logical Drive Power Saving disable time after 12:00AM on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::disableLdPSTime.{#SNMPINDEX}disableLdPSTime[{#SNMPVALUE}]6030dmLD power savings shall be disabled at xx minutes from 12:00am.MegaRAID SAS MIB Spin Down Hotspares on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::disableSpinDownHotSpare.{#SNMPINDEX}disableSpinDownHotSpare[{#SNMPVALUE}]6030dSpin Down Hotspares(0), Do Not Spin Down Hotspares(1)MegaRAID SAS MIB Domain ID of adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::domainId.{#SNMPINDEX}domainId[{#SNMPVALUE}]6030d0TEXTThis field gives the Domain IDMegaRAID SAS MIB Driver Version for adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::driverVersion.{#SNMPINDEX}driverVersion[{#SNMPVALUE}]6030d0TEXTDriver version Format->(Driver Name:Version)MegaRAID SAS MIB Enable SAS Pi on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::enablePI.{#SNMPINDEX}enablePI[{#SNMPVALUE}]6030d1 =Enable SAS PI for controller , 0 =Disable SAS PI for controllerMegaRAID SAS MIB Spin Down Unconfigured Drives on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::enableSpinDownUnconfigured.{#SNMPINDEX}enableSpinDownUnconfigured[{#SNMPVALUE}]6030dSpin Down Unconfigured Drives(1), Do Not Spin Down Unconfigured Drives(0)MegaRAID SAS MIB Expander Firmware Version for adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::expanderFirmwareVersion.{#SNMPINDEX}expanderFirmwareVersion[{#SNMPVALUE}]6030d0TEXTExpander firmware version - Not Available if expander is not present on the controllerMegaRAID SAS MIB Firmware Version for adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::firmwareVersion.{#SNMPINDEX}firmwareVersion[{#SNMPVALUE}]6030d0TEXTFirmware version Format->(Firmware Package Version:Version:Date:Time)MegaRAID SAS MIB Flash size on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::flashSize.{#SNMPINDEX}flashSize[{#SNMPVALUE}]6030dBFlash size in MB for this adapter.MULTIPLIER1048576MegaRAID SAS MIB Physical Drive force Offline Support on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::forceOffline.{#SNMPINDEX}forceOffline[{#SNMPVALUE}]6030dPhysical drive force Offline operation support. Values:notSupported(0), supported(1)MegaRAID SAS MIB Physical Drive force Online Support on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::forceOnline.{#SNMPINDEX}forceOnline[{#SNMPVALUE}]6030dPhysical drive force Online operation support. Values:notSupported(0), supported(1)MegaRAID SAS MIB Physical Drive force Rebuild Support on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::forceRebuild.{#SNMPINDEX}forceRebuild[{#SNMPVALUE}]6030dPhysical drive force Rebuild operation support. Values:notSupported(0), supported(1)MegaRAID SAS MIB Foreign Import Support for adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::foreignConfigImportSupported.{#SNMPINDEX}foreignConfigImportSupported[{#SNMPVALUE}]6030dSupport foreign config import on this adapter. Values:false(0),true(1)BOOL_TO_DECIMALMegaRAID SAS MIB Host Interface Port Address for Adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::hostInterfacePortAddr.{#SNMPINDEX}hostInterfacePortAddr[{#SNMPVALUE}]6030d0TEXTPort address comma delimitedMegaRAID SAS MIB Host Interface Port Count for Adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::hostInterfacePortCnt.{#SNMPINDEX}hostInterfacePortCnt[{#SNMPVALUE}]6030dPort Count on this adapter.MegaRAID SAS MIB Host Interface for Adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::hostInterface.{#SNMPINDEX}hostInterface[{#SNMPVALUE}]6030dHost interface information for this adapter.
Values:N/A(0),PCIX(1),PCIE(2),iSCSI(3),SAS-3G(4)MegaRAID SAS MIB Incompatibility details for adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::incompatibilityDetails.{#SNMPINDEX}incompatibilityDetails[{#SNMPVALUE}]6030d0TEXTThis field gives the Incompatibility DetailsMegaRAID SAS MIB Interrupt throttle active count on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::intThrottleCount.{#SNMPINDEX}intThrottleCount[{#SNMPVALUE}]6030dInterrupt throttle active count on this adapter.MegaRAID SAS MIB Interrupt throttle completion hold time on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::intThrottleTimeUs.{#SNMPINDEX}intThrottleTimeUs[{#SNMPVALUE}]6030dsInterrupt throttle completion hold time on this adapter.MULTIPLIER1000000MegaRAID SAS MIB Bad Block Management State on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::ldbbm.{#SNMPINDEX}ldbbm[{#SNMPVALUE}]6030d1=LD bad block management is enabled, 0=LD bad block management is not enabledMegaRAID SAS MIB Lock Key Assigned Support on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::lockKeyAssigned.{#SNMPINDEX}lockKeyAssigned[{#SNMPVALUE}]6030dLock key Assigned support for this Adapter. Values:false(0),true(1)MegaRAID SAS MIB Type of lock key binding for adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::lockKeyBinding.{#SNMPINDEX}lockKeyBinding[{#SNMPVALUE}]6030dType of lock key binding. lock key is not bound(0),lock key bound to FW secret key(1), lock key bound to user(2), lock key bound to a TPM(3)MegaRAID SAS MIB Lock Key Failed Support on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::lockKeyFailed.{#SNMPINDEX}lockKeyFailed[{#SNMPVALUE}]6030dlock Key Failed support for this Adapter. Values:false(0),true(1)MegaRAID SAS MIB Lock Key Not BackedUp Support on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::lockKeyNotBackedup.{#SNMPINDEX}lockKeyNotBackedup[{#SNMPVALUE}]6030dlock Key Not Backedup support for this Adapter. Values:false(0),true(1)MegaRAID SAS MIB Firmware support for Maintenance Mode on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::maintenanceMode.{#SNMPINDEX}maintenanceMode[{#SNMPVALUE}]6030d0TEXT1=FW supports maintenance modeMegaRAID SAS MIB Maximum arms per Virtual Drive supported for adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::maxArms.{#SNMPINDEX}maxArms[{#SNMPVALUE}]6030dMaximum arms per Virtual Drive supported for this Adapter.MegaRAID SAS MIB Maximum no of arrays supported for adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::maxArrays.{#SNMPINDEX}maxArrays[{#SNMPVALUE}]6030dMaximum no of arrays supported for this adapter.MegaRAID SAS MIB Maximum Parallel Commands Supported on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::maxConcurrentCmds.{#SNMPINDEX}maxConcurrentCmds[{#SNMPVALUE}]6030dThe maximum parallel commands supported on this adapter.MegaRAID SAS MIB Maximum number of drives to spinup within 60 sec for direct attached drives for adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::maxDAPdCountSpinup60.{#SNMPINDEX}maxDAPdCountSpinup60[{#SNMPVALUE}]6030dMaximum number of drives to spinup within 60 sec for direct attached drivesMegaRAID SAS MIB Maximum Configurable SSC Size on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::maximumCacheSize.{#SNMPINDEX}maximumCacheSize[{#SNMPVALUE}]6030dBThis field give the information about maximum Size of SSC that can yet be configured,in GBMULTIPLIER1073741824MegaRAID SAS MIB Maximum no of HA nodes supported by FW on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::maximumControllerNodes.{#SNMPINDEX}maximumControllerNodes[{#SNMPVALUE}]6030dThis field gives the HA nodes this FW supportsMegaRAID SAS MIB Maximum Logical Drives per Array on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::maxLdsPerArray.{#SNMPINDEX}maxLdsPerArray[{#SNMPVALUE}]6030dMax Ld's per array in adapterMegaRAID SAS MIB Maximum Data Transfer Size on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::maxRequestSize.{#SNMPINDEX}maxRequestSize[{#SNMPVALUE}]6030dsectorsThe maximum data transfer size in sectors, on this adapter.MegaRAID SAS MIB maximum Scatter Gather Element count allowed on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::maxSGECount.{#SNMPINDEX}maxSGECount[{#SNMPVALUE}]6030dThe maximum Scatter Gather Element count allowed on this adapter.MegaRAID SAS MIB Maximum spans per Virtual Drive supported for adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::maxSpans.{#SNMPINDEX}maxSpans[{#SNMPVALUE}]6030dMaximum spans per Virtual Drive supported for this Adapter.MegaRAID SAS MIB Maximum no of Virtual Drives supported for adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::maxVDs.{#SNMPINDEX}maxVDs[{#SNMPVALUE}]6030dMaximum number of Virtual Drives supported for this adapter.MegaRAID SAS MIB Memory size on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::memorySize.{#SNMPINDEX}memorySize[{#SNMPVALUE}]6030dBMemory size in MB for this adapter.MULTIPLIER1048576MegaRAID SAS MIB Multipath Support for adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::multipathSupport.{#SNMPINDEX}multipathSupport[{#SNMPVALUE}]6030dMultipath is supported or not supported on this adapter.Values:not supported(0),supported(1)MegaRAID SAS MIB NVRAM size on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::nvramSize.{#SNMPINDEX}nvramSize[{#SNMPVALUE}]6030dBNVRAM size in KB for this adapter.MULTIPLIER1024MegaRAID SAS MIB Maximum Logical Drives per Array in configuration on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::partitionsInDDF.{#SNMPINDEX}partitionsInDDF[{#SNMPVALUE}]6030dMax LD's per Array in configurationMegaRAID SAS MIB Patrol Read Rate Change Support for adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::patrolRateSupported.{#SNMPINDEX}patrolRateSupported[{#SNMPVALUE}]6030dPatrol read rate change support for this adapter. Values:false(0),true(1)BOOL_TO_DECIMALMegaRAID SAS MIB Patrol Read Rate on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::patrolReadRate.{#SNMPINDEX}patrolReadRate[{#SNMPVALUE}]6030d%Patrol Read Rate for this adapter.MegaRAID SAS MIB Failed Physical Disk Devices on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::pdDiskFailedCount.{#SNMPINDEX}pdDiskFailedCount[{#SNMPVALUE}]6030dNumber of disk devices in this adapter that are failed{last()}>0Failed disks detected on MegaRAID adapter {#SNMPVALUE}HIGHMegaRAID SAS MIB Physical Disk Devices with pre-fail state on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::pdDiskPredFailureCount.{#SNMPINDEX}pdDiskPredFailureCount[{#SNMPVALUE}]6030dNumber of disk devices in this adapter that are critical{last()}>0Disks with pre-fail state detected on MegaRAID adapter {#SNMPVALUE}HIGHMegaRAID SAS MIB Physical Disk Devices in adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::pdDiskPresentCount.{#SNMPINDEX}pdDiskPresentCount[{#SNMPVALUE}]6030dPhysical disk devices present in this adapter.MegaRAID SAS MIB Physical Devices in adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::pdPresentCount.{#SNMPINDEX}pdPresentCount[{#SNMPVALUE}]6030dPhysical devices present in this adapter.MegaRAID SAS MIB Peer Controller Status on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::peerControllerStatus.{#SNMPINDEX}peerControllerStatus[{#SNMPVALUE}]6030d0TEXTThis field gives the Peer controller StatusMegaRAID SAS MIB Predictive Fail Poll Interval on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::predFailPollInterval.{#SNMPINDEX}predFailPollInterval[{#SNMPVALUE}]6030dsNumber of seconds between precdictive fail polls on this adapter.MegaRAID SAS MIB Prevent import of SAS Pi protected LD on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::preventPIImport.{#SNMPINDEX}preventPIImport[{#SNMPVALUE}]6030d01=Prevent import of SAS PI protected logical disks , 0=Not Prevent import of SAS PI protected logical disksMegaRAID SAS MIB Adapter $1 Product NameSNMP_AGENTLSI-MegaRAID-SAS-MIB::productName.{#SNMPINDEX}productName[{#SNMPVALUE}]6030d0TEXTProduct name e.g. MegaRAID SAS-8E, MegaRAID SAS-4X, etc.MegaRAID SAS MIB Rebuilding Rate Change Support for adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::rbldRateSupported.{#SNMPINDEX}rbldRateSupported[{#SNMPVALUE}]6030dRebuilding rate change support for this Adapter. Values:false(0),true(1)BOOL_TO_DECIMALMegaRAID SAS MIB Reconstruction Rate Change Support for adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::reconRateSupported.{#SNMPINDEX}reconRateSupported[{#SNMPVALUE}]6030dReconstruction rate change support for this adapter. Values:false(0),true(1)BOOL_TO_DECIMALMegaRAID SAS MIB Reconstruction Rate on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::reconstructionRate.{#SNMPINDEX}reconstructionRate[{#SNMPVALUE}]6030d%Reconstruction rate on this Adapter.MegaRAID SAS MIB Revertible Hotspares Support for adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::revertibleHotSparesSupported.{#SNMPINDEX}revertibleHotSparesSupported[{#SNMPVALUE}]6030dRevertible HotSpares support for this adapter. Values:false(0),true(1)BOOL_TO_DECIMALMegaRAID SAS MIB Board Revision ID for adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::revisionIdentifier.{#SNMPINDEX}revisionIdentifier[{#SNMPVALUE}]6030d0TEXTBoard revision ID for this Adapter.MegaRAID SAS MIB Security Support for adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::securitySupported.{#SNMPINDEX}securitySupported[{#SNMPVALUE}]6030dDisplays the security support. if supported (1) , not supported (0)BOOL_TO_DECIMALMegaRAID SAS MIB Self Diagnostic Support for adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::selfDiagnosticSupported.{#SNMPINDEX}selfDiagnosticSupported[{#SNMPVALUE}]6030dController supports self diagnostic. Values:false(0),true(1)BOOL_TO_DECIMALMegaRAID SAS MIB Adapter $1 Controller Serial NumberSNMP_AGENTLSI-MegaRAID-SAS-MIB::serialNo.{#SNMPINDEX}serialNo[{#SNMPVALUE}]6030d0TEXTController serial numberMegaRAID SAS MIB FW requires application to set up power state before conf change on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::setPowerStateForCfg.{#SNMPINDEX}setPowerStateForCfg[{#SNMPVALUE}]6030dFW requires application to set power state before configuration changes. Required(1), Not Required(0)MegaRAID SAS MIB Spanning Support for adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::spanningAllowedSupported.{#SNMPINDEX}spanningAllowedSupported[{#SNMPVALUE}]6030dSpanning support for this adapter. Values:false(0),true(1)BOOL_TO_DECIMALMegaRAID SAS MIB Spin Down Time on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::spinDownTime.{#SNMPINDEX}spinDownTime[{#SNMPVALUE}]6030dmSpinDownTime in minutesMegaRAID SAS MIB Delay among spinup groups for this adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::spinupDelay.{#SNMPINDEX}spinupDelay[{#SNMPVALUE}]6030dsNumber of seconds to delay among spinup groups for this adapter.MegaRAID SAS MIB Maximum number of drives to spin up at one time for adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::spinupDriveCount.{#SNMPINDEX}spinupDriveCount[{#SNMPVALUE}]6030dMaximum number of drives to spin up at one time for this adapter.MegaRAID SAS MIB Delay Betwen Drive Spin Up in Enclosure on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::spinupEnclDelay.{#SNMPINDEX}spinupEnclDelay[{#SNMPVALUE}]6030dsDelay between drive spin up for drives within an enclosureMegaRAID SAS MIB Maximum Drives to Spin Up in Enclosure on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::spinupEnclDriveCount.{#SNMPINDEX}spinupEnclDriveCount[{#SNMPVALUE}]6030dmMaximum number of drives that can be spin up in an enclosureMegaRAID SAS MIB Copy back on SSD on SMART error on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::ssdSMARTerEnabled.{#SNMPINDEX}ssdSMARTerEnabled[{#SNMPVALUE}]6030dCopyback to SSD on SMART error. Values Enabled(0),Disabled(1)MegaRAID SAS MIB Adapter $1 PCI Sub-Device IDSNMP_AGENTLSI-MegaRAID-SAS-MIB::subDevID.{#SNMPINDEX}subDevID[{#SNMPVALUE}]6030d0TEXTPCI Sub-Device ID for this adapter.MegaRAID SAS MIB Adapter $1 PCI Sub-Vendor IDSNMP_AGENTLSI-MegaRAID-SAS-MIB::subVendorID.{#SNMPINDEX}subVendorID[{#SNMPVALUE}]6030d0TEXTPCI Sub-Vendor ID for this adapter.MegaRAID SAS MIB Break Mirror Operation Support on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::supportBreakMirror.{#SNMPINDEX}supportBreakMirror[{#SNMPVALUE}]6030d1=Support break mirror operation,0=Do not Support break mirror operationMegaRAID SAS MIB Configuration Auto Balance Support on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::supportConfigAutoBalance.{#SNMPINDEX}supportConfigAutoBalance[{#SNMPVALUE}]6030d0=no configuration auto balance support, 1=configuration auto balance support is presentMegaRAID SAS MIB Access Policy Support on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::supportedAccessPolicy.{#SNMPINDEX}supportedAccessPolicy[{#SNMPVALUE}]6030dAccess policy support. Values: false(0), true(1)MegaRAID SAS MIB IO Policy Support on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::supportedIOPolicy.{#SNMPINDEX}supportedIOPolicy[{#SNMPVALUE}]6030dIO policy support. Values: false(0), true(1)MegaRAID SAS MIB Maximum Stripe Size Supported on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::supportedMaxSize.{#SNMPINDEX}supportedMaxSize[{#SNMPVALUE}]6030dMaximum stripe size supported. 0(512B),1(1K),2(2K),3(4K),4(8K),5(16K),6(32),7(64K),8(128K) ... 11(1MB) etcMegaRAID SAS MIB Minimum Stripe Size Supported on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::supportedMinSize.{#SNMPINDEX}supportedMinSize[{#SNMPVALUE}]6030dMinimum stripe size supported. 0(512B),1(1K),2(2K),3(4K),4(8K),5(16K),6(32),7(64K),8(128K) ... 11(1MB) etcMegaRAID SAS MIB Read Policy Support on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::supportedReadPolicy.{#SNMPINDEX}supportedReadPolicy[{#SNMPVALUE}]6030dRead policy support. Values: false(0), true(1)MegaRAID SAS MIB FastPath WriteBack Support on Raptor LD for adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::supportFastPathWB.{#SNMPINDEX}supportFastPathWB[{#SNMPVALUE}]6030d1=Support Fast Path WB on Raptor Type Ld, 0=Does not support Fast Path WB on Raptor Type LdMegaRAID SAS MIB Online Firmware Update Support on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::supportOnlineFWUpdate.{#SNMPINDEX}supportOnlineFWUpdate[{#SNMPVALUE}]6030d1=Online firmware update is supported, 0=Online firmware update is not supportedMegaRAID SAS MIB PI Support for adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::supportPIcontroller.{#SNMPINDEX}supportPIcontroller[{#SNMPVALUE}]6030dDisplays the support PI. 1=LD SAS PI Type 0, 0=LD Not SAS PI Type 0BOOL_TO_DECIMALMegaRAID SAS MIB PD shield state support on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::supportShieldState.{#SNMPINDEX}supportShieldState[{#SNMPVALUE}]6030d1=Support PD shield state, 0=Not Support PD shield stateMegaRAID SAS MIB SAS Drive Support on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::supportsSAS.{#SNMPINDEX}supportsSAS[{#SNMPVALUE}]6030dSAS physical drive support. Values:notSupported(0), supported(1)MegaRAID SAS MIB SATA Drive Support on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::supportsSATA.{#SNMPINDEX}supportsSATA[{#SNMPVALUE}]6030dSATA physical drive support. Values:notSupported(0), supported(1)MegaRAID SAS MIB Controller Temperature on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::temperatureCtrl.{#SNMPINDEX}temperatureCtrl[{#SNMPVALUE}]6030d°Ctemperature of controller in CelsiusMegaRAID SAS MIB Raid On Chip Temperature on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::temperatureROC.{#SNMPINDEX}temperatureROC[{#SNMPVALUE}]6030d°Ctemperature of RAID On Chip in Celsius{last()}>115RECOVERY_EXPRESSION{last()}<105Critical temperature on Raid on Chip for adapter {#SNMPVALUE}HIGH{last()}>90RECOVERY_EXPRESSION{last()}<80High temperature on Raid on Chip for adapter {#SNMPVALUE}AVERAGEMegaRAID SAS MIB Topology Types info for adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::topologyType.{#SNMPINDEX}topologyType[{#SNMPVALUE}]6030d0TEXTThis field gives the Topology TypeMegaRAID SAS MIB Currently Confugured Total Cache Size on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::totalCacheSize.{#SNMPINDEX}totalCacheSize[{#SNMPVALUE}]6030dBThis field give the information about total Size of currently configured SSC,in GBMULTIPLIER1073741824MegaRAID SAS MIB Total Space used for MetaData on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::totalSpaceformetadata.{#SNMPINDEX}totalSpaceformetadata[{#SNMPVALUE}]6030dTotal Space used for MetaDataMegaRAID SAS MIB Use Emergency Spares for SMARTer on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::useEmergencySparesforSMARTer.{#SNMPINDEX}useEmergencySparesforSMARTer[{#SNMPVALUE}]6030d1 =Use Emergency spares for SMARTer ,0 =Not Use Emergency spares for SMARTerMegaRAID SAS MIB Emergency Spare Drive possible drive on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::useEmergencySpare.{#SNMPINDEX}useEmergencySpare[{#SNMPVALUE}]6030d0TEXTThis field give the information about Emergency Spare possible Drive types(Uncongiured Good/Global Hotspare)MegaRAID SAS MIB Degraded Virtual Devices in adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::vdDegradedCount.{#SNMPINDEX}vdDegradedCount[{#SNMPVALUE}]6030dNumber of virtual devices in this adapter that are critical{last()}>0Degraded Virtual devices on MegaRAID adapter {#SNMPVALUE}HIGHMegaRAID SAS MIB Offline Virtual Devices in adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::vdOfflineCount.{#SNMPINDEX}vdOfflineCount[{#SNMPVALUE}]6030dNumber of virtual devices in this adapter that are offline{last()}>0Offline Virtual devices on MegaRAID adapter {#SNMPVALUE}HIGHMegaRAID SAS MIB Virtual Devices in adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::vdPresentCount.{#SNMPINDEX}vdPresentCount[{#SNMPVALUE}]6030dVirtual devices present in this adapter.MegaRAID SAS MIB SSC Support Write Caching IO's on adapter $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::writeCacheCapable.{#SNMPINDEX}writeCacheCapable[{#SNMPVALUE}]6030d1=SSC support write caching IOs, 0=SSC not support write caching IOsTemperatures on MegaRAID adapter {#SNMPVALUE}0000FF- SNMP MegaRAID SAStemperatureCtrl[{#SNMPVALUE}]
1FF00FF- SNMP MegaRAID SAStemperatureROC[{#SNMPVALUE}]
MegaRAID SAS MIB SAS devicesSNMP_AGENTdiscovery[{#SNMPVALUE},LSI-MegaRAID-SAS-MIB::physDevID]physDevID60A List of device Entries containing Information/Properties about the MegaRAID related devices on host.MegaRAID SAS MIB Device $1 Adapter Port(s) to which it is connectedSNMP_AGENTLSI-MegaRAID-SAS-MIB::connectedAdapterPort.{#SNMPINDEX}connectedAdapterPort[{#SNMPVALUE}]600TEXTAdapter port(s) to which the device is connected.MegaRAID SAS MIB Maximum Supported Speed for Device $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::deviceSpeed.{#SNMPINDEX}deviceSpeed[{#SNMPVALUE}]60Maximum supported speed. Values:speed-unknown(0),speed-1p5G(1),speed-3G(2),speed-6G(3)MegaRAID SAS MIB Device $1 Ready for RemovalSNMP_AGENTLSI-MegaRAID-SAS-MIB::disabledForRemoval.{#SNMPINDEX}disabledForRemoval[{#SNMPVALUE}]60If true, drive is ready for removal. Values:false(0),true(1)MegaRAID SAS MIB Negotiated Link Speed for Device $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::linkSpeed.{#SNMPINDEX}linkSpeed[{#SNMPVALUE}]60Negotiated link speed. Values:speed-unknown(0),speed-1p5G(1),speed-3G(2),speed-6G(3){last()}=0Unknown Negotiated Link Speed for MegaRAID Drive {#SNMPVALUE}HIGHMegaRAID SAS MIB Media Error Count of Device $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::mediaErrCount.{#SNMPINDEX}mediaErrCount[{#SNMPVALUE}]60Error count of the deviceMegaRAID SAS MIB Device $1 Certtified by OEMSNMP_AGENTLSI-MegaRAID-SAS-MIB::oemCertified.{#SNMPINDEX}oemCertified[{#SNMPVALUE}]60Is the drive certified by the OEM (OEM-specific checks). Values:notCertified(1), Certified(0){last()}=0MegaRAID Device {#SNMPVALUE} not certified by OEMAVERAGEYESMegaRAID SAS MIB Device $1 Supported by OEMSNMP_AGENTLSI-MegaRAID-SAS-MIB::oemSupported.{#SNMPINDEX}oemSupported[{#SNMPVALUE}]60Is the drive supported by the OEM (OEM-specific checks). Values:notSupported(1), supported(0)MegaRAID SAS MIB Operation progress for Device $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::operationProgress.{#SNMPINDEX}operationProgress[{#SNMPVALUE}]600TEXTOperation progress in %. e.g. Rebuild progress is 10%MegaRAID SAS MIB Other Error Count of Device $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::otherErrCount.{#SNMPINDEX}otherErrCount[{#SNMPVALUE}]60Error count of the deviceMegaRAID SAS MIB Firmware Interpretation of state of Device $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::pdState.{#SNMPINDEX}pdState[{#SNMPVALUE}]60Firmware's interpretation of drive state.
Values:unconfigured-good(0),unconfigured-bad(1),hot-spare(2),offline(16),failed(17),rebuild(20),online(24),copyback(32),system(64),UNCONFIGURED-SHIELDED(128),HOTSPARE-SHIELDED(130),CONFIGURED-SHIELDED(144){last()}=17Failed state for MegaRAID Drive {#SNMPVALUE}HIGH{last()}=20Rebuilding state for MegaRAID Drive {#SNMPVALUE}WARNING{last()}=1Unconfigured Bad state for MegaRAID Drive {#SNMPVALUE}HIGHMegaRAID SAS MIB Device $1 TemperatureSNMP_AGENTLSI-MegaRAID-SAS-MIB::pdTemperature.{#SNMPINDEX}pdTemperature[{#SNMPVALUE}]60°CPhysical Drive temperature in Celsius{last()}>50RECOVERY_EXPRESSION{last()}<47MegaRAID Device {#SNMPVALUE} Temperature too highHIGHMegaRAID SAS MIB Predictive Fail Count of Device $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::predFailCount.{#SNMPINDEX}predFailCount[{#SNMPVALUE}]60Predictive fail count of the deviceMegaRAID SAS MIB Type of Device $1SNMP_AGENTLSI-MegaRAID-SAS-MIB::scsiDevType.{#SNMPINDEX}scsiDevType[{#SNMPVALUE}]60Type of this Device.
Values:disk(0),tape(1),printer(2),processor(3),cdrom(5),scanner(6),optical(7),enclosure(13),dvd(10),unknown(31)MegaRAID Physical Device {#SNMPVALUE} Temperature0000CC- SNMP MegaRAID SASpdTemperature[{#SNMPVALUE}]