zabbix_export: version: '6.0' date: '2021-11-21T21:26:08Z' groups: - uuid: 7df96b18c230490a9a0a9e2307226338 name: Templates templates: - uuid: 2995f3a7adbb492ab05460ab2088635f template: 'SNMP MegaRAID SAS' name: 'SNMP MegaRAID SAS' description: | ## Description Zabbix Template for Avago Megaraid SAS (formerly LSI) RAID cards ## Overview This is initial template for Monitoring LSI/Avago/Broadcom (or branded like Intel, IBM, Supermicro etc) MegaRAID based hardware RAID cards. According to vendor docs it should also support non-RAID adapters, enclosures and some other devices. It took me one night to complete major/required parts, so far template supports most of the options and all the critical components to keep you warned in case some RAID-related problems will occur. Supported so far: * Full LLD Support * Informational part for agent/driver/module * Complete Adapter-Related OID list with graphs and triggers * Part of Device-Related OID's with graphs * All triggers that are crucial * Comments for all OID's with value mappings from MegaRAID MIB Planned: * Value Mappings * Completing list of device OID's and related graphs * virtualDevice OID's and related graphs * enclosureInfo OID's and related graphs * Trap setting OID's * Traps for trapper * Check for updated version Not tested yet: * M$ Windows Support * Values and units are done as per MIB doc with 1-1 match, cannot guarantee that they are correct if vendor has provided wrong info (apparently, there is at least one minor issue) Installation and Requirements: * Ensure, that LSI-MegaRAID-SAS-MIB files downloaded from vendor site are installed and added to snmp.conf (after that you can restart both agent and server) * Ensure, that appropriate package (snmp sas or snmp sas\_ir) with MegaRAID snmp agent wrapper is installed and running, snmpd.conf for OID's are set as per doc for wrapper * Ensure, that Zabbix is allowed to gather information from snmpd * Ensure, that required device drivers are installed on the hosts * Import Template, assign to hosts * Wait for LLD to check all OID's and start gathering data * Have a good night's sleep Bugs? -> Please Report @GitHub or at giomac gmail com When will you finish this? -> Nah, all critical issues are included, will do, definitely, but not asap ## Author George Machitidze groups: - name: Templates items: - uuid: 85fb617c1cca495c920152dc715ca65b name: 'MegaRAID SAS MIB Number of SAS adapters present' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::adpNumber.0' key: adpNumber delay: '60' history: 30d triggers: - uuid: 6dbcbe8b9353405b8181a7d58bc4536d expression: 'last(/SNMP MegaRAID SAS/adpNumber)=0' name: 'No MegaRAID adapters present on host' priority: HIGH - uuid: 93ea9db3770a4d92a649a0f3d7c9b340 name: 'MegaRAID SAS MIB Agent Module Name' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::agentModuleName.0' key: agentModuleName delay: '60' history: 365d trends: '0' value_type: TEXT - uuid: c8de804b5ee049f29bac55ab99b165c4 name: 'MegaRAID SAS MIB Agent Module Version' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::agentModuleVersion.0' key: agentModuleVersion delay: '60' history: 365d trends: '0' value_type: TEXT triggers: - uuid: 185b0d25b6f4492386b5690af0a26cc8 expression: 'nodata(/SNMP MegaRAID SAS/agentModuleVersion,5m)=1' name: 'No SNMP data available for MegaRAID devices for 5 min' priority: HIGH - uuid: ce329ab820ae4908b32ba94503e01270 name: 'MegaRAID SAS MIB Version' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::mibVersion.0' key: mibVersion delay: '60' history: 365d trends: '0' value_type: TEXT discovery_rules: - uuid: 162f8b5e19b54b7fb4247aa3a8cbca05 name: 'MegaRAID SAS MIB SAS adapters' type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE},LSI-MegaRAID-SAS-MIB::adapterID]' key: adapterID delay: '900' description: 'A List of adapter Entries containing Information/Properties about the MegaRAID related adapters on host.' item_prototypes: - uuid: ef7e7ef761af44b68aa6daf8c275f0b9 name: 'MegaRAID SAS MIB Abort CC on detecting error support for adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::abortCConErrorSupported.{#SNMPINDEX}' key: 'abortCConErrorSupported[{#SNMPVALUE}]' delay: '60' history: 30d description: | Abort CC on detecting error is supported on this adapter. Values:No(0),Yes(1) preprocessing: - type: BOOL_TO_DECIMAL parameters: - '' - uuid: 487adbb185554669a387700db4c63279 name: 'MegaRAID SAS MIB Abort Consistency Check on error Adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::abortCConError.{#SNMPINDEX}' key: 'abortCConError[{#SNMPVALUE}]' delay: '60' history: 30d description: | Abort CC on detecting error is enabled or disabled on this adapter. Values:No(0),Yes(1),NA(2) - uuid: 7aafd6fcfa294ba8a16e453470072a84 name: 'MegaRAID SAS MIB Adapter $1 PCI Vendor ID' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::adapterVendorID.{#SNMPINDEX}' key: 'adapterVendorID[{#SNMPVALUE}]' delay: '60' history: 30d trends: '0' value_type: TEXT description: 'PCI Vendor ID for this Adapter.' - uuid: 8a3027be6da24e058d5ef00ee2121ecf name: 'MegaRAID SAS MIB Alarm Control Support for adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::alarmControlSupported.{#SNMPINDEX}' key: 'alarmControlSupported[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Alarm control support for this adapter. Values:false(0),true(1)' preprocessing: - type: BOOL_TO_DECIMAL parameters: - '' - uuid: 92297af8ef3d44a6bfe3fb09f028bde5 name: 'MegaRAID SAS MIB Alarm State on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::alarmState.{#SNMPINDEX}' key: 'alarmState[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Alarm is enabled or disabled on this adapter. Values:disabled(0),enabled(1)' preprocessing: - type: BOOL_TO_DECIMAL parameters: - '' - uuid: 32939cbc68c84528b3a49d9729b52df5 name: 'MegaRAID SAS MIB Controller encryption support on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::allowCtrlEncryption.{#SNMPINDEX}' key: 'allowCtrlEncryption[{#SNMPVALUE}]' delay: '60' history: 30d description: 'if it is set (1) supports controller encryption' - uuid: a0300e42fb2441ee8b94049aee0c012a name: 'MegaRAID SAS MIB Mixer Redundancy Support for adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::allowMixedRedundancyOnArraySupported.{#SNMPINDEX}' key: 'allowMixedRedundancyOnArraySupported[{#SNMPVALUE}]' delay: '60' history: 30d description: | Allow different Virtual Disk on the same array to have different redundancy levels. Values:false(0),true(1) preprocessing: - type: BOOL_TO_DECIMAL parameters: - '' - uuid: 69a526a8466941e5b2c6c2b149391eee name: 'MegaRAID SAS MIB Mix in Enclosure Support on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::allowMixInEnclosure.{#SNMPINDEX}' key: 'allowMixInEnclosure[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Mix InEnclosure support. Values:notSupported(0), supported(1)' - uuid: ce882123997743aea8ed67486e20bbb0 name: 'MegaRAID SAS MIB Mix in Virtual Drive Support on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::allowMixInVD.{#SNMPINDEX}' key: 'allowMixInVD[{#SNMPVALUE}]' delay: '60' history: 30d description: 'MixInVIRTUALDRIVE support. Values:notSupported(0), supported(1)' - uuid: c146a5069d03476d85cc4cafc9d66e22 name: 'MegaRAID SAS MIB Allow SSD/HDD Mix within LD on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::allowMixSSDHDDInLD.{#SNMPINDEX}' key: 'allowMixSSDHDDInLD[{#SNMPVALUE}]' delay: '60' history: 30d description: 'allow SSD/HDD mix within an LD.allow(1), not allow(0)' preprocessing: - type: BOOL_TO_DECIMAL parameters: - '' - uuid: 402482f3e1b54928a91c57a687105586 name: 'MegaRAID SAS MIB SATA in Cluster Support on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::allowSataInCluster.{#SNMPINDEX}' key: 'allowSataInCluster[{#SNMPVALUE}]' delay: '60' history: 30d description: 'SataInCluster support. Values:notSupported(0), supported(1)' - uuid: c678533092e642c88873664fb00f21d2 name: 'MegaRAID SAS MIB Allow SAS/SATA SSD within LD on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::allowSSDMixInLD.{#SNMPINDEX}' key: 'allowSSDMixInLD[{#SNMPVALUE}]' delay: '60' history: 30d description: 'allow SAS/SATA SSD mix within an LD. allow(1), not allow(0)' preprocessing: - type: BOOL_TO_DECIMAL parameters: - '' - uuid: dc46ca440fd646639f9868b415910724 name: 'MegaRAID SAS MIB Battery Backup Unit Support for adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::bbuSupported.{#SNMPINDEX}' key: 'bbuSupported[{#SNMPVALUE}]' delay: '60' history: 30d description: 'BBU support for this adapter. Values:false(0),true(1)' preprocessing: - type: BOOL_TO_DECIMAL parameters: - '' - uuid: 504a1c3c71ad42aca706c179b578f6e2 name: 'MegaRAID SAS MIB Background Initialization Rate Change Support for adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::bgiRateSupported.{#SNMPINDEX}' key: 'bgiRateSupported[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Background initialization rate change support for this adapter. Values:false(0),true(1)' preprocessing: - type: BOOL_TO_DECIMAL parameters: - '' - uuid: 45b8babf36254ed0a529925072b96448 name: 'MegaRAID SAS MIB Background Initialization Rate on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::bgiRate.{#SNMPINDEX}' key: 'bgiRate[{#SNMPVALUE}]' delay: '60' history: 30d units: '%' description: 'Background initialization rate for this adapter.' - uuid: e4d89baa22f241ab81dceec4da79d5c0 name: 'MegaRAID SAS MIB BIOS Not Detected Support on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::biosNotDetected.{#SNMPINDEX}' key: 'biosNotDetected[{#SNMPVALUE}]' delay: '60' history: 30d description: 'bios Not Detected support for this Adapter. Values:false(0),true(1)' - uuid: 492367d84a134512b71c8cf3f34cce0d name: 'MegaRAID SAS MIB Cache Flush Interval on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::cacheFlushInterval.{#SNMPINDEX}' key: 'cacheFlushInterval[{#SNMPVALUE}]' delay: '60' history: 30d units: s description: 'Cache flush interval in seconds for this adapter.' - uuid: fedcad935c9742cd91395e1877153c8d name: 'MegaRAID SAS MIB Controller Cache pinned for missing or offline LDs on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::cacheIsPinned.{#SNMPINDEX}' key: 'cacheIsPinned[{#SNMPVALUE}]' delay: '60' history: 30d description: '1=controller cache is pinned for missing or offline LDs' - uuid: 2aace43207584ae596fe874cdb69a6f7 name: 'MegaRAID SAS MIB Consistensy Check Rate Change Support for adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::ccRateSupported.{#SNMPINDEX}' key: 'ccRateSupported[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Consistency Check rate change support for this Adapter. Values:false(0),true(1)' preprocessing: - type: BOOL_TO_DECIMAL parameters: - '' - uuid: c666e2ebb91746ea8ae54bf7e52a1ecd name: 'MegaRAID SAS MIB Consistency Check Rate on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::ccRate.{#SNMPINDEX}' key: 'ccRate[{#SNMPVALUE}]' delay: '60' history: 30d units: '%' description: 'Consistency Check rate on this Adapter.' - uuid: d6c185c486eb433db6cec9684a2a1fcb name: 'MegaRAID SAS MIB Cluster State on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::clusterState.{#SNMPINDEX}' key: 'clusterState[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Cluster is enabled or disabled on this adapter. Values:disabled(0),enabled(1)' preprocessing: - type: BOOL_TO_DECIMAL parameters: - '' - uuid: 369922d166464391946a212fee5a9ef8 name: 'MegaRAID SAS MIB Cluster Support for adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::clusterSupported.{#SNMPINDEX}' key: 'clusterSupported[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Cluster support for this adapter. Values:false(0),true(1)' preprocessing: - type: BOOL_TO_DECIMAL parameters: - '' - uuid: c60e8b9d3c1d41c8b40329994eb7b7c1 name: 'MegaRAID SAS MIB Drive Capacity Coercion Mode on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::coercionMode.{#SNMPINDEX}' key: 'coercionMode[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Drive capacity coercion mode. 0->None;1->128MB;2->1GB' - uuid: 922d305aaea943a3b4393a4d56dfa048 name: 'MegaRAID SAS MIB Compatibility for adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::compatibilityFlag.{#SNMPINDEX}' key: 'compatibilityFlag[{#SNMPVALUE}]' delay: '60' history: 30d description: 'To inform compatibilities between Applications and FW. 0->incompatible;1->compatible' preprocessing: - type: BOOL_TO_DECIMAL parameters: - '' - uuid: 571f04773041447bb44fe07f0f81b755 name: 'MegaRAID SAS MIB Compatibility info for adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::compatibilityInfo.{#SNMPINDEX}' key: 'compatibilityInfo[{#SNMPVALUE}]' delay: '60' history: 30d trends: '0' value_type: TEXT description: 'Compatibility Information. Format->(Firmware Forward compatibility flag:Firmware Backward compatibility flag:Firmware version flag:Application Forward compatibility flag:Application Backward compatibility flag:Application version flag)' - uuid: e9de4970b7224bd7ba551c17c6167123 name: 'MegaRAID SAS MIB CopyBack state on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::copyBackState.{#SNMPINDEX}' key: 'copyBackState[{#SNMPVALUE}]' delay: '60' history: 30d description: 'CopyBack is enabled or disabled on this adapter.Values:disabled(0),enabled(1)' - uuid: 117a497e704445a78e451dc9049d4d93 name: 'MegaRAID SAS MIB Controller SAS Addresses on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::ctrlSasAddr.{#SNMPINDEX}' key: 'ctrlSasAddr[{#SNMPVALUE}]' delay: '60' history: 30d trends: '0' value_type: TEXT description: 'This field gives the controller SAS address' - uuid: dcaabf504c98462faefe68b0a7939e6f name: 'MegaRAID SAS MIB Dedicated Hotspares Support for adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::dedicatedHotSparesSupported.{#SNMPINDEX}' key: 'dedicatedHotSparesSupported[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Dedicated HotSpares support for this adapter. Values:false(0),true(1)' preprocessing: - type: BOOL_TO_DECIMAL parameters: - '' - uuid: 4b66f220ae214a9390b7782dc6cac1ec name: 'MegaRAID SAS MIB adapter $1 default power saving policy' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::defaultLdPSPolicy.{#SNMPINDEX}' key: 'defaultLdPSPolicy[{#SNMPVALUE}]' delay: '60' history: 30d description: 'power saving policy.values:controller default power saving policy=0, AUTO=1, MAX=2, Max with no cache=6, NONE=255' - uuid: b14d80ee0aa64b1faf2cc9273396e68d name: 'MegaRAID SAS MIB Adapter $1 PCI Device ID' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::devID.{#SNMPINDEX}' key: 'devID[{#SNMPVALUE}]' delay: '60' history: 30d trends: '0' value_type: TEXT description: 'PCI Device ID for this Adapter.' - uuid: 9385d034306842caaaac5a52f0f34599 name: 'MegaRAID SAS MIB Device Interface Port Addresses on Adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::devInterfacePortAddr.{#SNMPINDEX}' key: 'devInterfacePortAddr[{#SNMPVALUE}]' delay: '60' history: 30d trends: '0' value_type: TEXT description: 'Device Port address comma delimited' - uuid: db57c9ccc7db4210b7d0f55f82058330 name: 'MegaRAID SAS MIB Device Interface Port Count on Adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::devInterfacePortCnt.{#SNMPINDEX}' key: 'devInterfacePortCnt[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Device Port Count on this adapter.' - uuid: c55f8a1ea72e45c59ec75c84c71fa8ac name: 'MegaRAID SAS MIB Multiple Device Interface Support Values for Adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::devInterface.{#SNMPINDEX}' key: 'devInterface[{#SNMPVALUE}]' delay: '60' history: 30d trends: '0' value_type: TEXT description: 'Multiple device interface support values separated by space.' - uuid: e2ad25cfd65944a29f8915b3979d2527 name: 'MegaRAID SAS MIB Large IO Support on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::disableLargeIO.{#SNMPINDEX}' key: 'disableLargeIO[{#SNMPVALUE}]' delay: '60' history: 30d description: '0=Large IO is supported, 1=Large IO is unsupported' - uuid: ca188b202c6747568d153c3b0a85c15f name: 'MegaRAID SAS MIB Interval for disabling power saving after power saving time on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::disableLdPSInterval.{#SNMPINDEX}' key: 'disableLdPSInterval[{#SNMPVALUE}]' delay: '60' history: 30d units: h description: 'LD power savings are disabled for yy hours beginning at disableLdPSTime.' - uuid: e5f2a99a706645c58f35c8a62c673e4f name: 'MegaRAID SAS MIB Logical Drive Power Saving disable time after 12:00AM on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::disableLdPSTime.{#SNMPINDEX}' key: 'disableLdPSTime[{#SNMPVALUE}]' delay: '60' history: 30d units: m description: 'LD power savings shall be disabled at xx minutes from 12:00am.' - uuid: 8a6280257f494b6c823eea7a2d836efd name: 'MegaRAID SAS MIB Spin Down Hotspares on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::disableSpinDownHotSpare.{#SNMPINDEX}' key: 'disableSpinDownHotSpare[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Spin Down Hotspares(0), Do Not Spin Down Hotspares(1)' - uuid: 7028317c998548149fe98322567b2a84 name: 'MegaRAID SAS MIB Domain ID of adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::domainId.{#SNMPINDEX}' key: 'domainId[{#SNMPVALUE}]' delay: '60' history: 30d trends: '0' value_type: TEXT description: 'This field gives the Domain ID' - uuid: 3e3ee63d6eb0467fa4ca7026f4007d53 name: 'MegaRAID SAS MIB Driver Version for adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::driverVersion.{#SNMPINDEX}' key: 'driverVersion[{#SNMPVALUE}]' delay: '60' history: 30d trends: '0' value_type: TEXT description: 'Driver version Format->(Driver Name:Version)' - uuid: d10981c76af3479485da5d5fd7d25b99 name: 'MegaRAID SAS MIB Enable SAS Pi on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::enablePI.{#SNMPINDEX}' key: 'enablePI[{#SNMPVALUE}]' delay: '60' history: 30d description: '1 =Enable SAS PI for controller , 0 =Disable SAS PI for controller' - uuid: c4de709c6d274b238eb01e0e26ab05f5 name: 'MegaRAID SAS MIB Spin Down Unconfigured Drives on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::enableSpinDownUnconfigured.{#SNMPINDEX}' key: 'enableSpinDownUnconfigured[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Spin Down Unconfigured Drives(1), Do Not Spin Down Unconfigured Drives(0)' - uuid: 72bed8c4ffc94a1fbbfbc66e1713c62a name: 'MegaRAID SAS MIB Expander Firmware Version for adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::expanderFirmwareVersion.{#SNMPINDEX}' key: 'expanderFirmwareVersion[{#SNMPVALUE}]' delay: '60' history: 30d trends: '0' value_type: TEXT description: 'Expander firmware version - Not Available if expander is not present on the controller' - uuid: 9442127ffd104d3ba979af946e52c779 name: 'MegaRAID SAS MIB Firmware Version for adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::firmwareVersion.{#SNMPINDEX}' key: 'firmwareVersion[{#SNMPVALUE}]' delay: '60' history: 30d trends: '0' value_type: TEXT description: 'Firmware version Format->(Firmware Package Version:Version:Date:Time)' - uuid: e446c75c2bcb485ea305bfd223b4b0c4 name: 'MegaRAID SAS MIB Flash size on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::flashSize.{#SNMPINDEX}' key: 'flashSize[{#SNMPVALUE}]' delay: '60' history: 30d units: B description: 'Flash size in MB for this adapter.' preprocessing: - type: MULTIPLIER parameters: - '1048576' - uuid: 4f50e093e036460e9ae7cf6321c2ba90 name: 'MegaRAID SAS MIB Physical Drive force Offline Support on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::forceOffline.{#SNMPINDEX}' key: 'forceOffline[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Physical drive force Offline operation support. Values:notSupported(0), supported(1)' - uuid: dd9fc6e1d060407aa6e9cbba3b5038ea name: 'MegaRAID SAS MIB Physical Drive force Online Support on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::forceOnline.{#SNMPINDEX}' key: 'forceOnline[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Physical drive force Online operation support. Values:notSupported(0), supported(1)' - uuid: 2303720d12f0442da5d91eae03096004 name: 'MegaRAID SAS MIB Physical Drive force Rebuild Support on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::forceRebuild.{#SNMPINDEX}' key: 'forceRebuild[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Physical drive force Rebuild operation support. Values:notSupported(0), supported(1)' - uuid: f54dfe964f3f40759cc6c03270d1a15b name: 'MegaRAID SAS MIB Foreign Import Support for adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::foreignConfigImportSupported.{#SNMPINDEX}' key: 'foreignConfigImportSupported[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Support foreign config import on this adapter. Values:false(0),true(1)' preprocessing: - type: BOOL_TO_DECIMAL parameters: - '' - uuid: 1eea79767efd48b69ef85e010facc4a9 name: 'MegaRAID SAS MIB Host Interface Port Address for Adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::hostInterfacePortAddr.{#SNMPINDEX}' key: 'hostInterfacePortAddr[{#SNMPVALUE}]' delay: '60' history: 30d trends: '0' value_type: TEXT description: 'Port address comma delimited' - uuid: 427fc1c2b701460e8e9ac5a041be2fc3 name: 'MegaRAID SAS MIB Host Interface Port Count for Adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::hostInterfacePortCnt.{#SNMPINDEX}' key: 'hostInterfacePortCnt[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Port Count on this adapter.' - uuid: 1a317e7d52c7479d975ecfe59da958da name: 'MegaRAID SAS MIB Host Interface for Adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::hostInterface.{#SNMPINDEX}' key: 'hostInterface[{#SNMPVALUE}]' delay: '60' history: 30d description: | Host interface information for this adapter. Values:N/A(0),PCIX(1),PCIE(2),iSCSI(3),SAS-3G(4) - uuid: b161c1ec999e40f39eac230af7501765 name: 'MegaRAID SAS MIB Incompatibility details for adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::incompatibilityDetails.{#SNMPINDEX}' key: 'incompatibilityDetails[{#SNMPVALUE}]' delay: '60' history: 30d trends: '0' value_type: TEXT description: 'This field gives the Incompatibility Details' - uuid: f2b2dd61c2ec43919beab96a0cf0b2dd name: 'MegaRAID SAS MIB Interrupt throttle active count on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::intThrottleCount.{#SNMPINDEX}' key: 'intThrottleCount[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Interrupt throttle active count on this adapter.' - uuid: 93f17b2b6a5b45f8862d5ac7b7888a57 name: 'MegaRAID SAS MIB Interrupt throttle completion hold time on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::intThrottleTimeUs.{#SNMPINDEX}' key: 'intThrottleTimeUs[{#SNMPVALUE}]' delay: '60' history: 30d units: s description: 'Interrupt throttle completion hold time on this adapter.' preprocessing: - type: MULTIPLIER parameters: - '1000000' - uuid: 8b44394fa2a747a8a0f6bd4b4246a9fc name: 'MegaRAID SAS MIB Bad Block Management State on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::ldbbm.{#SNMPINDEX}' key: 'ldbbm[{#SNMPVALUE}]' delay: '60' history: 30d description: '1=LD bad block management is enabled, 0=LD bad block management is not enabled' - uuid: 7a138f8bb3fe481b9b04b9436d1275fc name: 'MegaRAID SAS MIB Lock Key Assigned Support on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::lockKeyAssigned.{#SNMPINDEX}' key: 'lockKeyAssigned[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Lock key Assigned support for this Adapter. Values:false(0),true(1)' - uuid: d0e9ba57066f4ee68fb73f740c929d66 name: 'MegaRAID SAS MIB Type of lock key binding for adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::lockKeyBinding.{#SNMPINDEX}' key: 'lockKeyBinding[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Type of lock key binding. lock key is not bound(0),lock key bound to FW secret key(1), lock key bound to user(2), lock key bound to a TPM(3)' - uuid: a18b175162524995b0e7984c340564ed name: 'MegaRAID SAS MIB Lock Key Failed Support on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::lockKeyFailed.{#SNMPINDEX}' key: 'lockKeyFailed[{#SNMPVALUE}]' delay: '60' history: 30d description: 'lock Key Failed support for this Adapter. Values:false(0),true(1)' - uuid: 64105d7be0be41d7bb02e94158fbfbff name: 'MegaRAID SAS MIB Lock Key Not BackedUp Support on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::lockKeyNotBackedup.{#SNMPINDEX}' key: 'lockKeyNotBackedup[{#SNMPVALUE}]' delay: '60' history: 30d description: 'lock Key Not Backedup support for this Adapter. Values:false(0),true(1)' - uuid: 996ffce77f8d4c219f61bb3f4894e639 name: 'MegaRAID SAS MIB Firmware support for Maintenance Mode on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::maintenanceMode.{#SNMPINDEX}' key: 'maintenanceMode[{#SNMPVALUE}]' delay: '60' history: 30d trends: '0' value_type: TEXT description: '1=FW supports maintenance mode' - uuid: 3a6c7814ec31422498e65c47788b3912 name: 'MegaRAID SAS MIB Maximum arms per Virtual Drive supported for adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::maxArms.{#SNMPINDEX}' key: 'maxArms[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Maximum arms per Virtual Drive supported for this Adapter.' - uuid: 13b52e889ccf49e2bce4ae204be73d35 name: 'MegaRAID SAS MIB Maximum no of arrays supported for adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::maxArrays.{#SNMPINDEX}' key: 'maxArrays[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Maximum no of arrays supported for this adapter.' - uuid: 3c88f87cd1bd48fb94883808e662b66d name: 'MegaRAID SAS MIB Maximum Parallel Commands Supported on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::maxConcurrentCmds.{#SNMPINDEX}' key: 'maxConcurrentCmds[{#SNMPVALUE}]' delay: '60' history: 30d description: 'The maximum parallel commands supported on this adapter.' - uuid: ec193c3592be45fbbb3f9da44fc1f2e6 name: 'MegaRAID SAS MIB Maximum number of drives to spinup within 60 sec for direct attached drives for adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::maxDAPdCountSpinup60.{#SNMPINDEX}' key: 'maxDAPdCountSpinup60[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Maximum number of drives to spinup within 60 sec for direct attached drives' - uuid: b989adcf2c59423999e9b7fd6da4b23c name: 'MegaRAID SAS MIB Maximum Configurable SSC Size on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::maximumCacheSize.{#SNMPINDEX}' key: 'maximumCacheSize[{#SNMPVALUE}]' delay: '60' history: 30d units: B description: 'This field give the information about maximum Size of SSC that can yet be configured,in GB' preprocessing: - type: MULTIPLIER parameters: - '1073741824' - uuid: 90fb5bce3e56464c99c60024f6835745 name: 'MegaRAID SAS MIB Maximum no of HA nodes supported by FW on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::maximumControllerNodes.{#SNMPINDEX}' key: 'maximumControllerNodes[{#SNMPVALUE}]' delay: '60' history: 30d description: 'This field gives the HA nodes this FW supports' - uuid: 301edfe9da06474b9d00e75d721a3d4d name: 'MegaRAID SAS MIB Maximum Logical Drives per Array on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::maxLdsPerArray.{#SNMPINDEX}' key: 'maxLdsPerArray[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Max Ld''s per array in adapter' - uuid: 26387eb9f4dd48c9bd517762d6bbaea5 name: 'MegaRAID SAS MIB Maximum Data Transfer Size on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::maxRequestSize.{#SNMPINDEX}' key: 'maxRequestSize[{#SNMPVALUE}]' delay: '60' history: 30d units: sectors description: 'The maximum data transfer size in sectors, on this adapter.' - uuid: b603fddb65934b8ea1857a5ced8e4ba2 name: 'MegaRAID SAS MIB maximum Scatter Gather Element count allowed on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::maxSGECount.{#SNMPINDEX}' key: 'maxSGECount[{#SNMPVALUE}]' delay: '60' history: 30d description: 'The maximum Scatter Gather Element count allowed on this adapter.' - uuid: eeae4f5e04e14e85af9de81ac8e1a1cb name: 'MegaRAID SAS MIB Maximum spans per Virtual Drive supported for adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::maxSpans.{#SNMPINDEX}' key: 'maxSpans[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Maximum spans per Virtual Drive supported for this Adapter.' - uuid: 8cf75a2ab6f148b5abf57f694dc5d3ba name: 'MegaRAID SAS MIB Maximum no of Virtual Drives supported for adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::maxVDs.{#SNMPINDEX}' key: 'maxVDs[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Maximum number of Virtual Drives supported for this adapter.' - uuid: f9268db58e58425c89e35ebb6a484639 name: 'MegaRAID SAS MIB Memory size on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::memorySize.{#SNMPINDEX}' key: 'memorySize[{#SNMPVALUE}]' delay: '60' history: 30d units: B description: 'Memory size in MB for this adapter.' preprocessing: - type: MULTIPLIER parameters: - '1048576' - uuid: 34de94532fb846bc94a99752346776f0 name: 'MegaRAID SAS MIB Multipath Support for adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::multipathSupport.{#SNMPINDEX}' key: 'multipathSupport[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Multipath is supported or not supported on this adapter.Values:not supported(0),supported(1)' - uuid: a770d313433c47bfaea5b4af8215342e name: 'MegaRAID SAS MIB NVRAM size on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::nvramSize.{#SNMPINDEX}' key: 'nvramSize[{#SNMPVALUE}]' delay: '60' history: 30d units: B description: 'NVRAM size in KB for this adapter.' preprocessing: - type: MULTIPLIER parameters: - '1024' - uuid: 9b73fec5258e4db8872b13d0439559ef name: 'MegaRAID SAS MIB Maximum Logical Drives per Array in configuration on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::partitionsInDDF.{#SNMPINDEX}' key: 'partitionsInDDF[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Max LD''s per Array in configuration' - uuid: ebf25d87760545a0b5d2f27e232e11fb name: 'MegaRAID SAS MIB Patrol Read Rate Change Support for adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::patrolRateSupported.{#SNMPINDEX}' key: 'patrolRateSupported[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Patrol read rate change support for this adapter. Values:false(0),true(1)' preprocessing: - type: BOOL_TO_DECIMAL parameters: - '' - uuid: 9c6c1161452d4c419ae97e9ccec6e21f name: 'MegaRAID SAS MIB Patrol Read Rate on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::patrolReadRate.{#SNMPINDEX}' key: 'patrolReadRate[{#SNMPVALUE}]' delay: '60' history: 30d units: '%' description: 'Patrol Read Rate for this adapter.' - uuid: 625e93b386e040788731e5e76d6622ef name: 'MegaRAID SAS MIB Failed Physical Disk Devices on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::pdDiskFailedCount.{#SNMPINDEX}' key: 'pdDiskFailedCount[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Number of disk devices in this adapter that are failed' trigger_prototypes: - uuid: 6321667794fa421781c2cbcfab948058 expression: 'last(/SNMP MegaRAID SAS/pdDiskFailedCount[{#SNMPVALUE}])>0' name: 'Failed disks detected on MegaRAID adapter {#SNMPVALUE}' priority: HIGH - uuid: 0a061b6d34de46ce8605e2d6ae848f76 name: 'MegaRAID SAS MIB Physical Disk Devices with pre-fail state on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::pdDiskPredFailureCount.{#SNMPINDEX}' key: 'pdDiskPredFailureCount[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Number of disk devices in this adapter that are critical' trigger_prototypes: - uuid: 01ed680e465043f782ecbc3f592e1382 expression: 'last(/SNMP MegaRAID SAS/pdDiskPredFailureCount[{#SNMPVALUE}])>0' name: 'Disks with pre-fail state detected on MegaRAID adapter {#SNMPVALUE}' priority: HIGH - uuid: 53e9221dba0f441eaa5fe7e3e35185a2 name: 'MegaRAID SAS MIB Physical Disk Devices in adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::pdDiskPresentCount.{#SNMPINDEX}' key: 'pdDiskPresentCount[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Physical disk devices present in this adapter.' - uuid: 90cf5024e0074e92b2348983ed42a56d name: 'MegaRAID SAS MIB Physical Devices in adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::pdPresentCount.{#SNMPINDEX}' key: 'pdPresentCount[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Physical devices present in this adapter.' - uuid: 3ae691fc1c674519895577dd2dc1d462 name: 'MegaRAID SAS MIB Peer Controller Status on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::peerControllerStatus.{#SNMPINDEX}' key: 'peerControllerStatus[{#SNMPVALUE}]' delay: '60' history: 30d trends: '0' value_type: TEXT description: 'This field gives the Peer controller Status' - uuid: 6de48788b0724b8fb646d90b84ac6404 name: 'MegaRAID SAS MIB Predictive Fail Poll Interval on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::predFailPollInterval.{#SNMPINDEX}' key: 'predFailPollInterval[{#SNMPVALUE}]' delay: '60' history: 30d units: s description: 'Number of seconds between precdictive fail polls on this adapter.' - uuid: 8f23d62904a7451abbde5857085ee56b name: 'MegaRAID SAS MIB Prevent import of SAS Pi protected LD on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::preventPIImport.{#SNMPINDEX}' key: 'preventPIImport[{#SNMPVALUE}]' delay: '60' history: 30d trends: '0' description: '1=Prevent import of SAS PI protected logical disks , 0=Not Prevent import of SAS PI protected logical disks' - uuid: a7707863dbbd4ea5bc7ef668ca72b403 name: 'MegaRAID SAS MIB Adapter $1 Product Name' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::productName.{#SNMPINDEX}' key: 'productName[{#SNMPVALUE}]' delay: '60' history: 30d trends: '0' value_type: TEXT description: 'Product name e.g. MegaRAID SAS-8E, MegaRAID SAS-4X, etc.' - uuid: 8a95b8679c754accb9ea460277182e28 name: 'MegaRAID SAS MIB Rebuilding Rate Change Support for adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::rbldRateSupported.{#SNMPINDEX}' key: 'rbldRateSupported[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Rebuilding rate change support for this Adapter. Values:false(0),true(1)' preprocessing: - type: BOOL_TO_DECIMAL parameters: - '' - uuid: edba09866d1b45e19315583e77e2efc4 name: 'MegaRAID SAS MIB Reconstruction Rate Change Support for adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::reconRateSupported.{#SNMPINDEX}' key: 'reconRateSupported[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Reconstruction rate change support for this adapter. Values:false(0),true(1)' preprocessing: - type: BOOL_TO_DECIMAL parameters: - '' - uuid: 1ee9e0c4f3ea46e0b23c191496bd2691 name: 'MegaRAID SAS MIB Reconstruction Rate on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::reconstructionRate.{#SNMPINDEX}' key: 'reconstructionRate[{#SNMPVALUE}]' delay: '60' history: 30d units: '%' description: 'Reconstruction rate on this Adapter.' - uuid: 0c6fb19dfeb84dda941bdcbb7fc26675 name: 'MegaRAID SAS MIB Revertible Hotspares Support for adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::revertibleHotSparesSupported.{#SNMPINDEX}' key: 'revertibleHotSparesSupported[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Revertible HotSpares support for this adapter. Values:false(0),true(1)' preprocessing: - type: BOOL_TO_DECIMAL parameters: - '' - uuid: 3006d2089661489daa8708725789c6f2 name: 'MegaRAID SAS MIB Board Revision ID for adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::revisionIdentifier.{#SNMPINDEX}' key: 'revisionIdentifier[{#SNMPVALUE}]' delay: '60' history: 30d trends: '0' value_type: TEXT description: 'Board revision ID for this Adapter.' - uuid: 3e409e1b9d5f43cf8cafa26585f76740 name: 'MegaRAID SAS MIB Security Support for adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::securitySupported.{#SNMPINDEX}' key: 'securitySupported[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Displays the security support. if supported (1) , not supported (0)' preprocessing: - type: BOOL_TO_DECIMAL parameters: - '' - uuid: 84bf1059179d4a2ba463e8861b6d5b82 name: 'MegaRAID SAS MIB Self Diagnostic Support for adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::selfDiagnosticSupported.{#SNMPINDEX}' key: 'selfDiagnosticSupported[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Controller supports self diagnostic. Values:false(0),true(1)' preprocessing: - type: BOOL_TO_DECIMAL parameters: - '' - uuid: 2b9f8abe57c74e1fa1b8e7ef6645e636 name: 'MegaRAID SAS MIB Adapter $1 Controller Serial Number' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::serialNo.{#SNMPINDEX}' key: 'serialNo[{#SNMPVALUE}]' delay: '60' history: 30d trends: '0' value_type: TEXT description: 'Controller serial number' - uuid: 0cd9246ce1444e7daa68b9773f6445db name: 'MegaRAID SAS MIB FW requires application to set up power state before conf change on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::setPowerStateForCfg.{#SNMPINDEX}' key: 'setPowerStateForCfg[{#SNMPVALUE}]' delay: '60' history: 30d description: 'FW requires application to set power state before configuration changes. Required(1), Not Required(0)' - uuid: 478bbdecc5ef4c29a30755edb861cbd4 name: 'MegaRAID SAS MIB Spanning Support for adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::spanningAllowedSupported.{#SNMPINDEX}' key: 'spanningAllowedSupported[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Spanning support for this adapter. Values:false(0),true(1)' preprocessing: - type: BOOL_TO_DECIMAL parameters: - '' - uuid: bda05bbda707435796cc060a4673b60c name: 'MegaRAID SAS MIB Spin Down Time on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::spinDownTime.{#SNMPINDEX}' key: 'spinDownTime[{#SNMPVALUE}]' delay: '60' history: 30d units: m description: 'SpinDownTime in minutes' - uuid: 0045595f65c348eebc2aabc17b9cb4c4 name: 'MegaRAID SAS MIB Delay among spinup groups for this adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::spinupDelay.{#SNMPINDEX}' key: 'spinupDelay[{#SNMPVALUE}]' delay: '60' history: 30d units: s description: 'Number of seconds to delay among spinup groups for this adapter.' - uuid: adf7336fd8a145d3ba7db011903ccf43 name: 'MegaRAID SAS MIB Maximum number of drives to spin up at one time for adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::spinupDriveCount.{#SNMPINDEX}' key: 'spinupDriveCount[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Maximum number of drives to spin up at one time for this adapter.' - uuid: b8f97311c17b4512abda666ac5228e3e name: 'MegaRAID SAS MIB Delay Betwen Drive Spin Up in Enclosure on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::spinupEnclDelay.{#SNMPINDEX}' key: 'spinupEnclDelay[{#SNMPVALUE}]' delay: '60' history: 30d units: s description: 'Delay between drive spin up for drives within an enclosure' - uuid: 5a841d1df81c48a4a76bba4e3a4e794c name: 'MegaRAID SAS MIB Maximum Drives to Spin Up in Enclosure on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::spinupEnclDriveCount.{#SNMPINDEX}' key: 'spinupEnclDriveCount[{#SNMPVALUE}]' delay: '60' history: 30d units: m description: 'Maximum number of drives that can be spin up in an enclosure' - uuid: 034f4527ff644483b4b73f7ac58e31fc name: 'MegaRAID SAS MIB Copy back on SSD on SMART error on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::ssdSMARTerEnabled.{#SNMPINDEX}' key: 'ssdSMARTerEnabled[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Copyback to SSD on SMART error. Values Enabled(0),Disabled(1)' - uuid: 231a24e726c546b5bb7bc2d8968299ea name: 'MegaRAID SAS MIB Adapter $1 PCI Sub-Device ID' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::subDevID.{#SNMPINDEX}' key: 'subDevID[{#SNMPVALUE}]' delay: '60' history: 30d trends: '0' value_type: TEXT description: 'PCI Sub-Device ID for this adapter.' - uuid: 0b26fa12e0b3407fbfda5306635fca1b name: 'MegaRAID SAS MIB Adapter $1 PCI Sub-Vendor ID' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::subVendorID.{#SNMPINDEX}' key: 'subVendorID[{#SNMPVALUE}]' delay: '60' history: 30d trends: '0' value_type: TEXT description: 'PCI Sub-Vendor ID for this adapter.' - uuid: 958c7ccf9c1144489f1fdb66504f892f name: 'MegaRAID SAS MIB Break Mirror Operation Support on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::supportBreakMirror.{#SNMPINDEX}' key: 'supportBreakMirror[{#SNMPVALUE}]' delay: '60' history: 30d description: '1=Support break mirror operation,0=Do not Support break mirror operation' - uuid: 6d0f04592a314adcb86df5286bd8c498 name: 'MegaRAID SAS MIB Configuration Auto Balance Support on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::supportConfigAutoBalance.{#SNMPINDEX}' key: 'supportConfigAutoBalance[{#SNMPVALUE}]' delay: '60' history: 30d description: '0=no configuration auto balance support, 1=configuration auto balance support is present' - uuid: efecca0e3a7f464f9b0963e2db349e8f name: 'MegaRAID SAS MIB Access Policy Support on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::supportedAccessPolicy.{#SNMPINDEX}' key: 'supportedAccessPolicy[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Access policy support. Values: false(0), true(1)' - uuid: a8b9535109ea461b93e63755faa46520 name: 'MegaRAID SAS MIB IO Policy Support on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::supportedIOPolicy.{#SNMPINDEX}' key: 'supportedIOPolicy[{#SNMPVALUE}]' delay: '60' history: 30d description: 'IO policy support. Values: false(0), true(1)' - uuid: 684cf31585684c60a5eef9e54d8359c3 name: 'MegaRAID SAS MIB Maximum Stripe Size Supported on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::supportedMaxSize.{#SNMPINDEX}' key: 'supportedMaxSize[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Maximum stripe size supported. 0(512B),1(1K),2(2K),3(4K),4(8K),5(16K),6(32),7(64K),8(128K) ... 11(1MB) etc' - uuid: 9900a10a418541c49757a30275eb9a42 name: 'MegaRAID SAS MIB Minimum Stripe Size Supported on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::supportedMinSize.{#SNMPINDEX}' key: 'supportedMinSize[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Minimum stripe size supported. 0(512B),1(1K),2(2K),3(4K),4(8K),5(16K),6(32),7(64K),8(128K) ... 11(1MB) etc' - uuid: c6ec3fe3723c4c82a494913d64210efd name: 'MegaRAID SAS MIB Read Policy Support on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::supportedReadPolicy.{#SNMPINDEX}' key: 'supportedReadPolicy[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Read policy support. Values: false(0), true(1)' - uuid: 318002da2c5c49feabaddf1d2ee57849 name: 'MegaRAID SAS MIB FastPath WriteBack Support on Raptor LD for adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::supportFastPathWB.{#SNMPINDEX}' key: 'supportFastPathWB[{#SNMPVALUE}]' delay: '60' history: 30d description: '1=Support Fast Path WB on Raptor Type Ld, 0=Does not support Fast Path WB on Raptor Type Ld' - uuid: 76846701eab74893a4151c29814105d4 name: 'MegaRAID SAS MIB Online Firmware Update Support on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::supportOnlineFWUpdate.{#SNMPINDEX}' key: 'supportOnlineFWUpdate[{#SNMPVALUE}]' delay: '60' history: 30d description: '1=Online firmware update is supported, 0=Online firmware update is not supported' - uuid: 9bab16e04f924459996e83c0978a0258 name: 'MegaRAID SAS MIB PI Support for adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::supportPIcontroller.{#SNMPINDEX}' key: 'supportPIcontroller[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Displays the support PI. 1=LD SAS PI Type 0, 0=LD Not SAS PI Type 0' preprocessing: - type: BOOL_TO_DECIMAL parameters: - '' - uuid: 809e873ec1e84bd0990879dbc779bd94 name: 'MegaRAID SAS MIB PD shield state support on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::supportShieldState.{#SNMPINDEX}' key: 'supportShieldState[{#SNMPVALUE}]' delay: '60' history: 30d description: '1=Support PD shield state, 0=Not Support PD shield state' - uuid: 5d6e4810d15740f492373e35a33f714f name: 'MegaRAID SAS MIB SAS Drive Support on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::supportsSAS.{#SNMPINDEX}' key: 'supportsSAS[{#SNMPVALUE}]' delay: '60' history: 30d description: 'SAS physical drive support. Values:notSupported(0), supported(1)' - uuid: 1ad4a7ce6dda464182b1f05a541d02e2 name: 'MegaRAID SAS MIB SATA Drive Support on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::supportsSATA.{#SNMPINDEX}' key: 'supportsSATA[{#SNMPVALUE}]' delay: '60' history: 30d description: 'SATA physical drive support. Values:notSupported(0), supported(1)' - uuid: cde7d9340c8349c4a1c8e9e7bae03879 name: 'MegaRAID SAS MIB Controller Temperature on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::temperatureCtrl.{#SNMPINDEX}' key: 'temperatureCtrl[{#SNMPVALUE}]' delay: '60' history: 30d units: °C description: 'temperature of controller in Celsius' - uuid: 89daa94c59684f18881216490fc73beb name: 'MegaRAID SAS MIB Raid On Chip Temperature on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::temperatureROC.{#SNMPINDEX}' key: 'temperatureROC[{#SNMPVALUE}]' delay: '60' history: 30d units: °C description: 'temperature of RAID On Chip in Celsius' trigger_prototypes: - uuid: a981f35ffcbf4ec3915cc859ca012ec3 expression: 'last(/SNMP MegaRAID SAS/temperatureROC[{#SNMPVALUE}])>115' recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'last(/SNMP MegaRAID SAS/temperatureROC[{#SNMPVALUE}])<105' name: 'Critical temperature on Raid on Chip for adapter {#SNMPVALUE}' priority: HIGH - uuid: db33899d04594522af08c9edf8e226c9 expression: 'last(/SNMP MegaRAID SAS/temperatureROC[{#SNMPVALUE}])>90' recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'last(/SNMP MegaRAID SAS/temperatureROC[{#SNMPVALUE}])<80' name: 'High temperature on Raid on Chip for adapter {#SNMPVALUE}' priority: AVERAGE - uuid: eddae321bf684be5832305b77cd2b37c name: 'MegaRAID SAS MIB Topology Types info for adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::topologyType.{#SNMPINDEX}' key: 'topologyType[{#SNMPVALUE}]' delay: '60' history: 30d trends: '0' value_type: TEXT description: 'This field gives the Topology Type' - uuid: 7b3b24d6a2cc41cc9994de952c31c8ba name: 'MegaRAID SAS MIB Currently Confugured Total Cache Size on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::totalCacheSize.{#SNMPINDEX}' key: 'totalCacheSize[{#SNMPVALUE}]' delay: '60' history: 30d units: B description: 'This field give the information about total Size of currently configured SSC,in GB' preprocessing: - type: MULTIPLIER parameters: - '1073741824' - uuid: 0d93e5c4eb1948f2b2d802c62d6396e5 name: 'MegaRAID SAS MIB Total Space used for MetaData on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::totalSpaceformetadata.{#SNMPINDEX}' key: 'totalSpaceformetadata[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Total Space used for MetaData' - uuid: 4a8155dccabe4637ba2c897e687a1a8b name: 'MegaRAID SAS MIB Use Emergency Spares for SMARTer on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::useEmergencySparesforSMARTer.{#SNMPINDEX}' key: 'useEmergencySparesforSMARTer[{#SNMPVALUE}]' delay: '60' history: 30d description: '1 =Use Emergency spares for SMARTer ,0 =Not Use Emergency spares for SMARTer' - uuid: e52b500ac6d649ba8199a35ff3a957da name: 'MegaRAID SAS MIB Emergency Spare Drive possible drive on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::useEmergencySpare.{#SNMPINDEX}' key: 'useEmergencySpare[{#SNMPVALUE}]' delay: '60' history: 30d trends: '0' value_type: TEXT description: 'This field give the information about Emergency Spare possible Drive types(Uncongiured Good/Global Hotspare)' - uuid: 279e5409558042a398d5429b42de9478 name: 'MegaRAID SAS MIB Degraded Virtual Devices in adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::vdDegradedCount.{#SNMPINDEX}' key: 'vdDegradedCount[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Number of virtual devices in this adapter that are critical' trigger_prototypes: - uuid: 76ed072a802f4c17aadca3f52338c8be expression: 'last(/SNMP MegaRAID SAS/vdDegradedCount[{#SNMPVALUE}])>0' name: 'Degraded Virtual devices on MegaRAID adapter {#SNMPVALUE}' priority: HIGH - uuid: 1ce6d496bf8c4bfb93475608521e2173 name: 'MegaRAID SAS MIB Offline Virtual Devices in adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::vdOfflineCount.{#SNMPINDEX}' key: 'vdOfflineCount[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Number of virtual devices in this adapter that are offline' trigger_prototypes: - uuid: a06eddff4a634f18ae9c1a1efaa00493 expression: 'last(/SNMP MegaRAID SAS/vdOfflineCount[{#SNMPVALUE}])>0' name: 'Offline Virtual devices on MegaRAID adapter {#SNMPVALUE}' priority: HIGH - uuid: f5e92d3a9eb04959b85f41d5d25bcce1 name: 'MegaRAID SAS MIB Virtual Devices in adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::vdPresentCount.{#SNMPINDEX}' key: 'vdPresentCount[{#SNMPVALUE}]' delay: '60' history: 30d description: 'Virtual devices present in this adapter.' - uuid: 6111adba53854c01aca08e711436af64 name: 'MegaRAID SAS MIB SSC Support Write Caching IO''s on adapter $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::writeCacheCapable.{#SNMPINDEX}' key: 'writeCacheCapable[{#SNMPVALUE}]' delay: '60' history: 30d description: '1=SSC support write caching IOs, 0=SSC not support write caching IOs' graph_prototypes: - uuid: cddb4bd752f24c069df7463e22864c18 name: 'Temperatures on MegaRAID adapter {#SNMPVALUE}' graph_items: - color: 0000FF item: host: 'SNMP MegaRAID SAS' key: 'temperatureCtrl[{#SNMPVALUE}]' - sortorder: '1' color: FF00FF item: host: 'SNMP MegaRAID SAS' key: 'temperatureROC[{#SNMPVALUE}]' - uuid: 712d4e6fd1d745e9b8ab20cf90bbdef8 name: 'MegaRAID SAS MIB SAS devices' type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE},LSI-MegaRAID-SAS-MIB::physDevID]' key: physDevID delay: '60' description: 'A List of device Entries containing Information/Properties about the MegaRAID related devices on host.' item_prototypes: - uuid: 51283954041e436dbd2f5e3b781ccfce name: 'MegaRAID SAS MIB Device $1 Adapter Port(s) to which it is connected' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::connectedAdapterPort.{#SNMPINDEX}' key: 'connectedAdapterPort[{#SNMPVALUE}]' delay: '60' trends: '0' value_type: TEXT description: 'Adapter port(s) to which the device is connected.' - uuid: e7feea1b656c4eca8b2003c4b9a5a90e name: 'MegaRAID SAS MIB Maximum Supported Speed for Device $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::deviceSpeed.{#SNMPINDEX}' key: 'deviceSpeed[{#SNMPVALUE}]' delay: '60' description: 'Maximum supported speed. Values:speed-unknown(0),speed-1p5G(1),speed-3G(2),speed-6G(3)' - uuid: a55f9f6823f04b9ea3db300f11559c58 name: 'MegaRAID SAS MIB Device $1 Ready for Removal' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::disabledForRemoval.{#SNMPINDEX}' key: 'disabledForRemoval[{#SNMPVALUE}]' delay: '60' description: 'If true, drive is ready for removal. Values:false(0),true(1)' - uuid: 48c54f856a62457f97e03696092a94ec name: 'MegaRAID SAS MIB Negotiated Link Speed for Device $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::linkSpeed.{#SNMPINDEX}' key: 'linkSpeed[{#SNMPVALUE}]' delay: '60' description: 'Negotiated link speed. Values:speed-unknown(0),speed-1p5G(1),speed-3G(2),speed-6G(3)' trigger_prototypes: - uuid: 712fb7cad9f34ceaa151bcec68405a89 expression: 'last(/SNMP MegaRAID SAS/linkSpeed[{#SNMPVALUE}])=0' name: 'Unknown Negotiated Link Speed for MegaRAID Drive {#SNMPVALUE}' priority: HIGH - uuid: 7cf6c61db6714c4ca3f3fe0176cffa3d name: 'MegaRAID SAS MIB Media Error Count of Device $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::mediaErrCount.{#SNMPINDEX}' key: 'mediaErrCount[{#SNMPVALUE}]' delay: '60' description: 'Error count of the device' - uuid: d3390bc4afc44220a44ff15ec2fdf121 name: 'MegaRAID SAS MIB Device $1 Certtified by OEM' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::oemCertified.{#SNMPINDEX}' key: 'oemCertified[{#SNMPVALUE}]' delay: '60' description: 'Is the drive certified by the OEM (OEM-specific checks). Values:notCertified(1), Certified(0)' trigger_prototypes: - uuid: 7f0193a29e1544959333efa0cf6565f0 expression: 'last(/SNMP MegaRAID SAS/oemCertified[{#SNMPVALUE}])=0' name: 'MegaRAID Device {#SNMPVALUE} not certified by OEM' priority: AVERAGE manual_close: 'YES' - uuid: 0cef4ae580b140008e1550b5e70b106f name: 'MegaRAID SAS MIB Device $1 Supported by OEM' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::oemSupported.{#SNMPINDEX}' key: 'oemSupported[{#SNMPVALUE}]' delay: '60' description: 'Is the drive supported by the OEM (OEM-specific checks). Values:notSupported(1), supported(0)' - uuid: 1621086bc79b49d280e3d6bea1f51a00 name: 'MegaRAID SAS MIB Operation progress for Device $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::operationProgress.{#SNMPINDEX}' key: 'operationProgress[{#SNMPVALUE}]' delay: '60' trends: '0' value_type: TEXT description: 'Operation progress in %. e.g. Rebuild progress is 10%' - uuid: 68060cd490324de28b9cefb77c16bdcc name: 'MegaRAID SAS MIB Other Error Count of Device $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::otherErrCount.{#SNMPINDEX}' key: 'otherErrCount[{#SNMPVALUE}]' delay: '60' description: 'Error count of the device' - uuid: cb6ab4710cee4235866fe0782e366d66 name: 'MegaRAID SAS MIB Firmware Interpretation of state of Device $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::pdState.{#SNMPINDEX}' key: 'pdState[{#SNMPVALUE}]' delay: '60' description: | Firmware's interpretation of drive state. Values:unconfigured-good(0),unconfigured-bad(1),hot-spare(2),offline(16),failed(17),rebuild(20),online(24),copyback(32),system(64),UNCONFIGURED-SHIELDED(128),HOTSPARE-SHIELDED(130),CONFIGURED-SHIELDED(144) trigger_prototypes: - uuid: 37d40d8a0bb546b5a507269e3218e9f7 expression: 'last(/SNMP MegaRAID SAS/pdState[{#SNMPVALUE}])=17' name: 'Failed state for MegaRAID Drive {#SNMPVALUE}' priority: HIGH - uuid: 1c98f4abd39f4c0f8eb8abe1e657b3ea expression: 'last(/SNMP MegaRAID SAS/pdState[{#SNMPVALUE}])=20' name: 'Rebuilding state for MegaRAID Drive {#SNMPVALUE}' priority: WARNING - uuid: cfb17f977b3f46dfa3ef8d77fa37efa0 expression: 'last(/SNMP MegaRAID SAS/pdState[{#SNMPVALUE}])=1' name: 'Unconfigured Bad state for MegaRAID Drive {#SNMPVALUE}' priority: HIGH - uuid: 85208a0e77e24a5498212f163a132021 name: 'MegaRAID SAS MIB Device $1 Temperature' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::pdTemperature.{#SNMPINDEX}' key: 'pdTemperature[{#SNMPVALUE}]' delay: '60' units: °C description: 'Physical Drive temperature in Celsius' trigger_prototypes: - uuid: c8b389cd3dc94fe4982f41ae3f4bea8c expression: 'last(/SNMP MegaRAID SAS/pdTemperature[{#SNMPVALUE}])>50' recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'last(/SNMP MegaRAID SAS/pdTemperature[{#SNMPVALUE}])<47' name: 'MegaRAID Device {#SNMPVALUE} Temperature too high' priority: HIGH - uuid: 7cbd7877921b4c62993631d7f5213153 name: 'MegaRAID SAS MIB Predictive Fail Count of Device $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::predFailCount.{#SNMPINDEX}' key: 'predFailCount[{#SNMPVALUE}]' delay: '60' description: 'Predictive fail count of the device' - uuid: 9e021f58f73d4bf38f6b1dc7c44060ac name: 'MegaRAID SAS MIB Type of Device $1' type: SNMP_AGENT snmp_oid: 'LSI-MegaRAID-SAS-MIB::scsiDevType.{#SNMPINDEX}' key: 'scsiDevType[{#SNMPVALUE}]' delay: '60' description: | Type of this Device. Values:disk(0),tape(1),printer(2),processor(3),cdrom(5),scanner(6),optical(7),enclosure(13),dvd(10),unknown(31) graph_prototypes: - uuid: def97b1560d04fc49b736ec955293c6b name: 'MegaRAID Physical Device {#SNMPVALUE} Temperature' graph_items: - color: 0000CC item: host: 'SNMP MegaRAID SAS' key: 'pdTemperature[{#SNMPVALUE}]'