zabbix_export: version: '5.4' date: '2021-11-21T21:23:37Z' groups: - uuid: 7df96b18c230490a9a0a9e2307226338 name: Templates templates: - uuid: 83d3a9eebd7e4a638a35a831a955255e template: UNISIM_IPMI_SGI_Altix_ISS3114 name: '3-IPMI SGI Altix ISS3114' description: | ## Overview IPMI sensors for SGI Altix ISS3114: Agg Therm Mgn 1, BB +1.05Vccp P1, BB +1.05Vccp P2, BB +1.1V STBY, BB +1.5 P1MEM AB, BB +1.5 P1MEM CD, BB +1.5 P2MEM AB, BB +1.5 P2MEM CD, BB +1.8V AUX, BB +3.3V, BB +3.3V AUX, BB +3.3V Vbat, BB +5.0V, BB +5.0V STBY, BB +12.0V, BB P1 VR Temp, BB P2 VR Temp, BB Vtt 1 Temp, BB Vtt 2 Temp, DIMM Thrm Mrgn 1, DIMM Thrm Mrgn 2, DIMM Thrm Mrgn 3, DIMM Thrm Mrgn 4, Exit Air Temp, Fan 1 Present, Fan 2 Present, Fan 3 Present, Fan 4 Present, Fan 5 Present, Fan Redundancy, Front Panel Temp, HDD 0 Status, HDD 1 Status, HDD 2 Status, HDD 3 Status, HDD 4 Status, HDD 5 Status, HDD 6 Status, HDD 7 Status, HDD 8 Status, HDD 9 Status, HDD 10 Status, HDD 11 Status, HDD 12 Status, HDD 13 Status, HDD 14 Status, HDD 15 Status, HDD 16 Status, HDD 17 Status, HDD 18 Status, HDD 19 Status, HDD 20 Status, HDD 21 Status, HDD 22 Status, HDD 23 Status, HSBP 1 Temp, HSBP 2 Temp, HSBP 3 Temp, LAN NIC Temp, P1 DTS Therm Mgn, P1 Therm Margin, P2 DTS Therm Mgn, P2 Therm Margin, Power Triggers 1, PS1 Curr Out %, PS1 Fan Fail, PS1 Input Power, PS1 Status, PS1 Temperature, PS2 Curr Out %, PS2 Fan Fail, PS2 Input Power, PS2 Status, PS2 Temperature, Pwr Unit Redund, SSB Temp, System Airflow, System Fan 1, System Fan 2, System Fan 3, System Fan 4, System Fan 5 ## Author Daniel Carvalho groups: - name: Templates items: - uuid: f9f5ee9b4aae4f119db9283674814a8a name: 'Agg Therm Mgn 1' type: IPMI key: ipmi.agg.therm.mgn.1 delay: '300' history: 7d value_type: FLOAT units: C ipmi_sensor: 'Agg Therm Mgn 1' tags: - tag: Application value: 'Temperature Sensors' - uuid: 2e67f09372e04a979c3588723dc97191 name: 'BB +1.05Vccp P1' type: IPMI key: ipmi.bb.1.05vccp.p1 delay: '300' history: 7d value_type: FLOAT units: V ipmi_sensor: 'BB +1.05Vccp P1' tags: - tag: Application value: 'Voltage Sensors' triggers: - uuid: 73adf5dd6e714562afb9361b44d27160 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.05vccp.p1)<=0.540) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.05vccp.p1)<=0.552)' name: 'BB +1.05Vccp P1 voltage lower critical on {HOSTNAME}' priority: HIGH - uuid: b52d4ea3334044ed9296515f562c2ef3 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.05vccp.p1)<=0.552) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.05vccp.p1)<=0.564)' name: 'BB +1.05Vccp P1 voltage lower non-critical on {HOSTNAME}' priority: AVERAGE - uuid: fb9c8eda74a14a4f828a489328103453 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.05vccp.p1)>=1.506) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.05vccp.p1)>=1.464)' name: 'BB +1.05Vccp P1 voltage upper critical on {HOSTNAME}' priority: HIGH - uuid: 9c38c90aba7845209c79f0f7e3994bac expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.05vccp.p1)>=1.464) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.05vccp.p1)>=1.422)' name: 'BB +1.05Vccp P1 voltage upper non-critical on {HOSTNAME}' priority: AVERAGE - uuid: 821fe71ed9ee4a7ca9769103b40695a5 name: 'BB +1.05Vccp P2' type: IPMI key: ipmi.bb.1.05vccp.p2 delay: '300' history: 7d value_type: FLOAT units: V ipmi_sensor: 'BB +1.05Vccp P2' tags: - tag: Application value: 'Voltage Sensors' triggers: - uuid: 222f36cbf168435bbb5af20b6b4ee79d expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.05vccp.p2)<=0.540) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.05vccp.p2)<=0.552)' name: 'BB +1.05Vccp P2 voltage lower critical on {HOSTNAME}' priority: HIGH - uuid: 9dfa531596ba422ea978f03fcf2b87a8 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.05vccp.p2)<=0.552) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.05vccp.p2)<=0.564)' name: 'BB +1.05Vccp P2 voltage lower non-critical on {HOSTNAME}' priority: AVERAGE - uuid: 301c260e147f4cf58c4ff0cfd516e85f expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.05vccp.p2)>=1.506) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.05vccp.p2)>=1.464)' name: 'BB +1.05Vccp P2 voltage upper critical on {HOSTNAME}' priority: HIGH - uuid: 67869dd5da144b108aa37ced7c9ff7ae expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.05vccp.p2)>=1.464) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.05vccp.p2)>=1.422)' name: 'BB +1.05Vccp P2 voltage upper non-critical on {HOSTNAME}' priority: AVERAGE - uuid: a406335230044bbd86b11fe19b381aeb name: 'BB +1.1V STBY' type: IPMI key: ipmi.bb.1.1v.stby delay: '300' history: 7d value_type: FLOAT units: V ipmi_sensor: 'BB +1.1V STBY' tags: - tag: Application value: 'Voltage Sensors' triggers: - uuid: ec994d68c74f464db3dbd81d57d12d53 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.1v.stby)<=0.938) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.1v.stby)<=0.964)' name: 'BB +1.1V STBY voltage lower critical on {HOSTNAME}' priority: HIGH - uuid: 1df491adc8ff4525b5011649f81e8f9b expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.1v.stby)<=0.964) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.1v.stby)<=0.990)' name: 'BB +1.1V STBY voltage lower non-critical on {HOSTNAME}' priority: AVERAGE - uuid: 66bf3acedb154be0847789a85a63e5e0 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.1v.stby)>=1.276) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.1v.stby)>=1.240)' name: 'BB +1.1V STBY voltage upper critical on {HOSTNAME}' priority: HIGH - uuid: c4fef882c07a4a3d967cebac5527fb2a expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.1v.stby)>=1.240) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.1v.stby)>=1.204)' name: 'BB +1.1V STBY voltage upper non-critical on {HOSTNAME}' priority: AVERAGE - uuid: ae3afc0b1d604df6afc2ae6f4c100e0c name: 'BB +1.5 P1MEM AB' type: IPMI key: ipmi.bb.1.5p1mem.ab delay: '300' history: 7d value_type: FLOAT units: V ipmi_sensor: 'BB +1.5 P1MEM AB' tags: - tag: Application value: 'Voltage Sensors' triggers: - uuid: 21b64ff402e3404dab5d9313e7f95906 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.5p1mem.ab)<=1.339) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.5p1mem.ab)<=1.387)' name: 'BB +1.5 P1MEM AB voltage lower critical on {HOSTNAME}' priority: HIGH - uuid: 30f80e20261b437aa0e4032b680f469b expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.5p1mem.ab)<=1.387) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.5p1mem.ab)<=1.435)' name: 'BB +1.5 P1MEM AB voltage lower non-critical on {HOSTNAME}' priority: AVERAGE - uuid: b4d2259b6d4544689bcaf493e2de2ecd expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.5p1mem.ab)>=1.659) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.5p1mem.ab)>=1.611)' name: 'BB +1.5 P1MEM AB voltage upper critical on {HOSTNAME}' priority: HIGH - uuid: 6f65d8f7e3dd4f50b4244260b70311a9 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.5p1mem.ab)>=1.611) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.5p1mem.ab)>=1.563)' name: 'BB +1.5 P1MEM AB voltage upper non-critical on {HOSTNAME}' priority: AVERAGE - uuid: 92425ab75b3c4fb480b01d2da6315134 name: 'BB +1.5 P1MEM CD' type: IPMI key: ipmi.bb.1.5p1mem.cd delay: '300' history: 7d value_type: FLOAT units: V ipmi_sensor: 'BB +1.5 P1MEM CD' tags: - tag: Application value: 'Voltage Sensors' triggers: - uuid: 0ee0cbe240b84527b1e144e8e617b3f6 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.5p1mem.cd)<=1.339) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.5p1mem.cd)<=1.387)' name: 'BB +1.5 P1MEM CD voltage lower critical on {HOSTNAME}' priority: HIGH - uuid: f66a0dabdbb34bd59821c4cdb60ddda2 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.5p1mem.cd)<=1.387) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.5p1mem.cd)<=1.435)' name: 'BB +1.5 P1MEM CD voltage lower non-critical on {HOSTNAME}' priority: AVERAGE - uuid: c08c7718f6584093a0567d6af742fe6b expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.5p1mem.cd)>=1.659) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.5p1mem.cd)>=1.611)' name: 'BB +1.5 P1MEM CD voltage upper critical on {HOSTNAME}' priority: HIGH - uuid: 11560848a6134e11a163b237b8b84895 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.5p1mem.cd)>=1.611) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.5p1mem.cd)>=1.563)' name: 'BB +1.5 P1MEM CD voltage upper non-critical on {HOSTNAME}' priority: AVERAGE - uuid: 825d50bc24f0413a989c237cb8b231fc name: 'BB +1.5 P2MEM AB' type: IPMI key: ipmi.bb.1.5p2mem.ab delay: '300' history: 7d value_type: FLOAT units: V ipmi_sensor: 'BB +1.5 P2MEM AB' tags: - tag: Application value: 'Voltage Sensors' triggers: - uuid: f7cfb0274eac436b921412f26a05363b expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.5p2mem.ab)<=1.339) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.5p2mem.ab)<=1.387)' name: 'BB +1.5 P2MEM AB voltage lower critical on {HOSTNAME}' priority: HIGH - uuid: 565f4611de774eda82275b9e99f6f2f7 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.5p2mem.ab)<=1.387) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.5p2mem.ab)<=1.435)' name: 'BB +1.5 P2MEM AB voltage lower non-critical on {HOSTNAME}' priority: AVERAGE - uuid: 3ac91eeb746b426585fcce9f1ab7b929 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.5p2mem.ab)>=1.659) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.5p2mem.ab)>=1.611)' name: 'BB +1.5 P2MEM AB voltage upper critical on {HOSTNAME}' priority: HIGH - uuid: b6e5ef37d0cc48e4baa143685cbf2c18 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.5p2mem.ab)>=1.611) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.5p2mem.ab)>=1.563)' name: 'BB +1.5 P2MEM AB voltage upper non-critical on {HOSTNAME}' priority: AVERAGE - uuid: dce9f62601ef44f1a52eccbff0ff658d name: 'BB +1.5 P2MEM CD' type: IPMI key: ipmi.bb.1.5p2mem.cd delay: '300' history: 7d value_type: FLOAT units: V ipmi_sensor: 'BB +1.5 P2MEM CD' tags: - tag: Application value: 'Voltage Sensors' triggers: - uuid: a7b0599011134cf9a1f341e3e0156163 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.5p2mem.cd)<=1.339) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.5p2mem.cd)<=1.387)' name: 'BB +1.5 P2MEM CD voltage lower critical on {HOSTNAME}' priority: HIGH - uuid: f8fba4f286164b6798a50e48f5b320f2 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.5p2mem.cd)<=1.387) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.5p2mem.cd)<=1.435)' name: 'BB +1.5 P2MEM CD voltage lower non-critical on {HOSTNAME}' priority: AVERAGE - uuid: 4a4daac2875243ecb256759f28b5b354 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.5p2mem.cd)>=1.659) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.5p2mem.cd)>=1.611)' name: 'BB +1.5 P2MEM CD voltage upper critical on {HOSTNAME}' priority: HIGH - uuid: df486da3b55f4bdc9d07c7f4a5ee1007 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.5p2mem.cd)>=1.611) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.5p2mem.cd)>=1.563)' name: 'BB +1.5 P2MEM CD voltage upper non-critical on {HOSTNAME}' priority: AVERAGE - uuid: d66a7cc25ab243ed84e25ce526a354af name: 'BB +1.8V AUX' type: IPMI key: ipmi.bb.1.8v.aux delay: '300' history: 7d value_type: FLOAT units: V ipmi_sensor: 'BB +1.8V AUX' tags: - tag: Application value: 'Voltage Sensors' triggers: - uuid: 3a9b9c6522044ee799122aba173b9874 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.8v.aux)<=1.644) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.8v.aux)<=1.702)' name: 'BB +1.8V AUX voltage lower critical on {HOSTNAME}' priority: HIGH - uuid: def846e6e5e5409eb78dd9877465d6ed expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.8v.aux)<=1.702) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.8v.aux)<=1.760)' name: 'BB +1.8V AUX voltage lower non-critical on {HOSTNAME}' priority: AVERAGE - uuid: f7ecb11071d04f1bb17b619d951a3eab expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.8v.aux)>=1.960) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.8v.aux)>=1.902)' name: 'BB +1.8V AUX voltage upper critical on {HOSTNAME}' priority: HIGH - uuid: b2f87dfe5c304317b99c267b006174af expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.8v.aux)>=1.902) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.1.8v.aux)>=1.844)' name: 'BB +1.8V AUX voltage upper non-critical on {HOSTNAME}' priority: AVERAGE - uuid: 8befbff28b224e9fadad39c28ca1d0c8 name: 'BB +3.3V' type: IPMI key: ipmi.bb.3.3v delay: '300' history: 7d value_type: FLOAT units: V ipmi_sensor: 'BB +3.3V' tags: - tag: Application value: 'Voltage Sensors' triggers: - uuid: bdf107b0bf584d21b705fc9f4d5c5ec6 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.3.3v)<=2.953) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.3.3v)<=3.039)' name: 'BB +3.3V voltage lower critical on {HOSTNAME}' priority: HIGH - uuid: a4aae94bbb6f491baf768056d3f49d3e expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.3.3v)<=3.039) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.3.3v)<=3.125)' name: 'BB +3.3V voltage lower non-critical on {HOSTNAME}' priority: AVERAGE - uuid: 78e27809a54e4ec0a0824a33ee685c1d expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.3.3v)>=3.654) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.3.3v)>=3.554)' name: 'BB +3.3V voltage upper critical on {HOSTNAME}' priority: HIGH - uuid: 1dc553cabd7c44da8d283fc6e98fbc70 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.3.3v)>=3.554) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.3.3v)>=3.454)' name: 'BB +3.3V voltage upper non-critical on {HOSTNAME}' priority: AVERAGE - uuid: cdda09cc60a5439c9934fdbb6562a39d name: 'BB +3.3V AUX' type: IPMI key: ipmi.bb.3.3v.aux delay: '300' history: 7d value_type: FLOAT units: V ipmi_sensor: 'BB +3.3V AUX' tags: - tag: Application value: 'Voltage Sensors' triggers: - uuid: df28e78bd8c34e2e964998827aa39d39 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.3.3v.aux)<=2.953) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.3.3v.aux)<=3.039)' name: 'BB +3.3V AUX voltage lower critical on {HOSTNAME}' priority: HIGH - uuid: 6c3fc062f7b549d4a0bc5eb36e19dadf expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.3.3v.aux)<=3.039) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.3.3v.aux)<=3.125)' name: 'BB +3.3V AUX voltage lower non-critical on {HOSTNAME}' priority: AVERAGE - uuid: 8f4aa763630d48d9b93ff387f58285fa expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.3.3v.aux)>=3.654) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.3.3v.aux)>=3.554)' name: 'BB +3.3V AUX voltage upper critical on {HOSTNAME}' priority: HIGH - uuid: be6dec2a345b47868e1be6b48e09aaaa expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.3.3v.aux)>=3.554) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.3.3v.aux)>=3.454)' name: 'BB +3.3V AUX voltage upper non-critical on {HOSTNAME}' priority: AVERAGE - uuid: 95eaaa00e89f4e85837ed438248d9f9f name: 'BB +3.3V Vbat' type: IPMI key: ipmi.bb.3.3v.vbat delay: '300' history: 7d value_type: FLOAT units: V ipmi_sensor: 'BB +3.3V Vbat' tags: - tag: Application value: 'Voltage Sensors' triggers: - uuid: 78697b01850c471cbdd4dac50ab6564a expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.3.3v.vbat)<=2.211) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.3.3v.vbat)<=2.544)' name: 'BB +3.3V Vbat voltage lower critical on {HOSTNAME}' priority: HIGH - uuid: aa0d6a56407c4c4cbecd9a199ed58a57 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.3.3v.vbat)<=2.544) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.3.3v.vbat)<=2.877)' name: 'BB +3.3V Vbat voltage lower non-critical on {HOSTNAME}' priority: AVERAGE - uuid: 5a22eb918d52423bb03c4ee95d9e5308 name: 'BB +5.0V' type: IPMI key: ipmi.bb.5v delay: '300' history: 7d value_type: FLOAT units: V ipmi_sensor: 'BB +5.0V' tags: - tag: Application value: 'Voltage Sensors' triggers: - uuid: 5c119b1d215f4a268baa56004e70a2e7 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.5v)<=4.416) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.5v)<=4.546)' name: 'BB +5.0V voltage lower critical on {HOSTNAME}' priority: HIGH - uuid: f0b64e2893c843e5a9725af263e30fe7 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.5v)<=4.546) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.5v)<=5.676)' name: 'BB +5.0V voltage lower non-critical on {HOSTNAME}' priority: AVERAGE - uuid: 0451bfdb599a463d99d87468af97a770 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.5v)>=5.566) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.5v)>=5.415)' name: 'BB +5.0V voltage upper critical on {HOSTNAME}' priority: HIGH - uuid: ed96c4790dc94319b03b59fefee11dcb expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.5v)>=5.415) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.5v)>=5.264)' name: 'BB +5.0V voltage upper non-critical on {HOSTNAME}' priority: AVERAGE - uuid: a75d371db643445498bde6ee1e9eff0c name: 'BB +5.0V STBY' type: IPMI key: ipmi.bb.5v.stby delay: '300' history: 7d value_type: FLOAT units: V ipmi_sensor: 'BB +5.0V STBY' tags: - tag: Application value: 'Voltage Sensors' triggers: - uuid: c7c3804adb7a40c9bbf0049eb957b1f1 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.5v.stby)<=4.460) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.5v.stby)<=4.590)' name: 'BB +5.0V STBY voltage lower critical on {HOSTNAME}' priority: HIGH - uuid: 3fc68ee7d2834fd58a45aed0ac9339d8 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.5v.stby)<=4.590) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.5v.stby)<=5.720)' name: 'BB +5.0V STBY voltage lower non-critical on {HOSTNAME}' priority: AVERAGE - uuid: 9cb72b896fee45448e3762ab9e15b149 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.5v.stby)>=5.566) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.5v.stby)>=5.415)' name: 'BB +5.0V STBY voltage upper critical on {HOSTNAME}' priority: HIGH - uuid: 8657be7185824b3a89b620eba1574db1 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.5v.stby)>=5.415) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.5v.stby)>=5.264)' name: 'BB +5.0V STBY voltage upper non-critical on {HOSTNAME}' priority: AVERAGE - uuid: 3db635455d444243a3d6a15152033f97 name: 'BB +12.0V' type: IPMI key: ipmi.bb.12v delay: '300' history: 7d value_type: FLOAT units: V ipmi_sensor: 'BB +12.0V' tags: - tag: Application value: 'Voltage Sensors' triggers: - uuid: eede50096ebb48369ebc82ea7c04bfc5 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.12v)<=10.635) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.12v)<=10.947)' name: 'BB +12.0V voltage lower critical on {HOSTNAME}' priority: HIGH - uuid: fa365e8656f14dfb966cb29a65dd5b85 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.12v)<=10.947) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.12v)<=11.259)' name: 'BB +12.0V voltage lower non-critical on {HOSTNAME}' priority: AVERAGE - uuid: a9ea5a2caf4046ffae4510ccd51624fc expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.12v)>=13.391) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.12v)>=13.027)' name: 'BB +12.0V voltage upper critical on {HOSTNAME}' priority: HIGH - uuid: 7211c9223f9b4d9597fd35c24462427f expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.12v)>=13.027) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.12v)>=12.663)' name: 'BB +12.0V voltage upper non-critical on {HOSTNAME}' priority: AVERAGE - uuid: c842a52bb8464b53b2a38cff208af2c5 name: 'BB P1 VR Temp' type: IPMI key: ipmi.bb.p1.vr.temp delay: '300' history: 7d units: C ipmi_sensor: 'BB P1 VR Temp' tags: - tag: Application value: 'Temperature Sensors' triggers: - uuid: fe89dd3cd3144132a5e2398dd0566be6 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.p1.vr.temp)<=0) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.p1.vr.temp)<=5)' name: 'BB P1 VR Temp temperature lower critical on {HOSTNAME}' priority: HIGH - uuid: 4ba93be64d5c40c4b1a369d16eb927f5 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.p1.vr.temp)<=5) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.p1.vr.temp)<=10)' name: 'BB P1 VR Temp temperature lower non-critical on {HOSTNAME}' priority: AVERAGE - uuid: 9ce158d3baf84496af5cb02c303ed7eb expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.p1.vr.temp)>=115) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.p1.vr.temp)>=110)' name: 'BB P1 VR Temp temperature upper critical on {HOSTNAME}' priority: HIGH - uuid: 0fb22e188fa941b1adb4a2b0bf1b637a expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.p1.vr.temp)>=110) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.p1.vr.temp)>=105)' name: 'BB P1 VR Temp temperature upper non-critical on {HOSTNAME}' priority: AVERAGE - uuid: 6cfcabbdff5c481c9889b9eca0fe4df5 name: 'BB P2 VR Temp' type: IPMI key: ipmi.bb.p2.vr.temp delay: '300' history: 7d units: C ipmi_sensor: 'BB P2 VR Temp' tags: - tag: Application value: 'Temperature Sensors' triggers: - uuid: 15c785c3b87a45d2b981004b65d83a7c expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.p2.vr.temp)<=0) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.p2.vr.temp)<=5)' name: 'BB P2 VR Temp temperature lower critical on {HOSTNAME}' priority: HIGH - uuid: 211a6f569f0240e0b4abd8a14a719067 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.p2.vr.temp)<=5) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.p2.vr.temp)<=10)' name: 'BB P2 VR Temp temperature lower non-critical on {HOSTNAME}' priority: AVERAGE - uuid: 0a5ea50ef8844986a4af6463f181a186 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.p2.vr.temp)>=115) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.p2.vr.temp)>=110)' name: 'BB P2 VR Temp temperature upper critical on {HOSTNAME}' priority: HIGH - uuid: 3162434858a7450fb019baf5a9dd1e1d expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.p2.vr.temp)>=110) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.p2.vr.temp)>=105)' name: 'BB P2 VR Temp temperature upper non-critical on {HOSTNAME}' priority: AVERAGE - uuid: ed90e4d0124c48be88b4733fdf754517 name: 'SSB Temp' type: IPMI key: ipmi.bb.ssb.temp delay: '300' history: 7d units: C ipmi_sensor: 'SSB Temp' tags: - tag: Application value: 'Temperature Sensors' triggers: - uuid: 4bf250d7b1d44cd3ae958facdc873091 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.ssb.temp)<=0) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.ssb.temp)<=5)' name: 'SSB Temp temperature lower critical on {HOSTNAME}' priority: HIGH - uuid: 4dc5764d7e744154be679185521d20ed expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.ssb.temp)<=5) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.ssb.temp)<=10)' name: 'SSB Temp temperature lower non-critical on {HOSTNAME}' priority: AVERAGE - uuid: ee3e27fa086749a7a943ce3be9c877bd expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.ssb.temp)>=103) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.ssb.temp)>=98)' name: 'SSB Temp temperature upper critical on {HOSTNAME}' priority: HIGH - uuid: 110de72c29184136a0d2c92e2223a293 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.ssb.temp)>=98) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.ssb.temp)>=93)' name: 'SSB Temp temperature upper non-critical on {HOSTNAME}' priority: AVERAGE - uuid: 818a1fa4cd37447782858192e81aa0c2 name: 'BB Vtt 1 Temp' type: IPMI key: ipmi.bb.vtt.1.temp delay: '300' history: 7d units: C ipmi_sensor: 'BB Vtt 1 Temp' tags: - tag: Application value: 'Temperature Sensors' triggers: - uuid: 0bb14b0387974916bd577de3686d305c expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.vtt.1.temp)<=0) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.vtt.1.temp)<=5)' name: 'BB Vtt 1 Temp temperature lower critical on {HOSTNAME}' priority: HIGH - uuid: 44e662b53b074c18a34534e9a8a10ec9 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.vtt.1.temp)<=5) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.vtt.1.temp)<=10)' name: 'BB Vtt 1 Temp temperature lower non-critical on {HOSTNAME}' priority: AVERAGE - uuid: 0ef5d76a16804a86bc93ce94519c8e2c expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.vtt.1.temp)>=115) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.vtt.1.temp)>=110)' name: 'BB Vtt 1 Temp temperature upper critical on {HOSTNAME}' priority: HIGH - uuid: 12a1f3c7774a4584a4c23c4919d20c9e expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.vtt.1.temp)>=110) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.vtt.1.temp)>=105)' name: 'BB Vtt 1 Temp temperature upper non-critical on {HOSTNAME}' priority: AVERAGE - uuid: b6c1a17ba9484e4da37b12a58111ef34 name: 'BB Vtt 2 Temp' type: IPMI key: ipmi.bb.vtt.2.temp delay: '300' history: 7d units: C ipmi_sensor: 'BB Vtt 2 Temp' tags: - tag: Application value: 'Temperature Sensors' triggers: - uuid: 351b261ed1b04c62b89b1c71f9d75a32 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.vtt.2.temp)<=0) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.vtt.2.temp)<=5)' name: 'BB Vtt 2 Temp temperature lower critical on {HOSTNAME}' priority: HIGH - uuid: 82210276bb754693bea568411a761a33 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.vtt.2.temp)<=5) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.vtt.2.temp)<=10)' name: 'BB Vtt 2 Temp temperature lower non-critical on {HOSTNAME}' priority: AVERAGE - uuid: 2594b21bccac4d8fb6cbcc54845266a2 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.vtt.2.temp)>=115) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.vtt.2.temp)>=110)' name: 'BB Vtt 2 Temp temperature upper critical on {HOSTNAME}' priority: HIGH - uuid: d8b5b6f5d17848b482fa7f4294e33744 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.vtt.2.temp)>=110) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.bb.vtt.2.temp)>=105)' name: 'BB Vtt 2 Temp temperature upper non-critical on {HOSTNAME}' priority: AVERAGE - uuid: 929379a031234be88d2eba650abdaafd name: 'DIMM Thrm Mrgn 1' type: IPMI key: ipmi.dimm.thrm.mrgn.1 delay: '300' history: 7d value_type: FLOAT units: C ipmi_sensor: 'DIMM Thrm Mrgn 1' tags: - tag: Application value: 'Temperature Sensors' triggers: - uuid: b05955c8fbf944a78d3ab58333bfe1ef expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.dimm.thrm.mrgn.1)>=10) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.dimm.thrm.mrgn.1)>=5)' name: 'DIMM Thrm Mrgn 1 temperature upper critical on {HOSTNAME}' priority: HIGH - uuid: 2536c670106e40d39fb9b2c2d253b9dd expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.dimm.thrm.mrgn.1)>=5) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.dimm.thrm.mrgn.1)>=0)' name: 'DIMM Thrm Mrgn 1 temperature upper non-critical on {HOSTNAME}' priority: AVERAGE - uuid: 17e5929d595b43bd8050be7f9388d6f7 name: 'DIMM Thrm Mrgn 2' type: IPMI key: ipmi.dimm.thrm.mrgn.2 delay: '300' history: 7d value_type: FLOAT units: C ipmi_sensor: 'DIMM Thrm Mrgn 2' tags: - tag: Application value: 'Temperature Sensors' triggers: - uuid: ca2f0c13d7144e328f1103887f5327a1 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.dimm.thrm.mrgn.2)>=10) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.dimm.thrm.mrgn.2)>=5)' name: 'DIMM Thrm Mrgn 2 temperature upper critical on {HOSTNAME}' priority: HIGH - uuid: 51dae148b18c4fd3bb9ccbff08b84337 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.dimm.thrm.mrgn.2)>=5) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.dimm.thrm.mrgn.2)>=0)' name: 'DIMM Thrm Mrgn 2 temperature upper non-critical on {HOSTNAME}' priority: AVERAGE - uuid: 70a73256552248d3be3aef9e8a43f29b name: 'DIMM Thrm Mrgn 3' type: IPMI key: ipmi.dimm.thrm.mrgn.3 delay: '300' history: 7d value_type: FLOAT units: C ipmi_sensor: 'DIMM Thrm Mrgn 3' tags: - tag: Application value: 'Temperature Sensors' triggers: - uuid: 5327f095d5df457f85bd0088212fc5c7 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.dimm.thrm.mrgn.3)>=10) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.dimm.thrm.mrgn.3)>=5)' name: 'DIMM Thrm Mrgn 3 temperature upper critical on {HOSTNAME}' priority: HIGH - uuid: fd7513a74bde43bebfc379f88b1e9459 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.dimm.thrm.mrgn.3)>=5) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.dimm.thrm.mrgn.3)>=0)' name: 'DIMM Thrm Mrgn 3 temperature upper non-critical on {HOSTNAME}' priority: AVERAGE - uuid: 9f13b2f540834d7b9885eb4946393b36 name: 'DIMM Thrm Mrgn 4' type: IPMI key: ipmi.dimm.thrm.mrgn.4 delay: '300' history: 7d value_type: FLOAT units: C ipmi_sensor: 'DIMM Thrm Mrgn 4' tags: - tag: Application value: 'Temperature Sensors' triggers: - uuid: 130f533297814ada80b3dae793f9d72e expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.dimm.thrm.mrgn.4)>=10) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.dimm.thrm.mrgn.4)>=5)' name: 'DIMM Thrm Mrgn 4 temperature upper critical on {HOSTNAME}' priority: HIGH - uuid: a3b94557e3e046fcbf23b6cd3a2370c6 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.dimm.thrm.mrgn.4)>=5) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.dimm.thrm.mrgn.4)>=0)' name: 'DIMM Thrm Mrgn 4 temperature upper non-critical on {HOSTNAME}' priority: AVERAGE - uuid: da53cb3510ac4212a8b2c048aa6e12a5 name: 'Exit Air Temp' type: IPMI key: ipmi.exit.air.temp delay: '300' history: 7d units: C ipmi_sensor: 'Exit Air Temp' tags: - tag: Application value: 'Temperature Sensors' triggers: - uuid: fb9b0c93013d4deb8bfa80123ef076c8 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.exit.air.temp)<=0) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.exit.air.temp)<=5)' name: 'Exit Air Temp temperature lower critical on {HOSTNAME}' priority: HIGH - uuid: 0b21a25774b443eda0057947257c33a8 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.exit.air.temp)<=5) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.exit.air.temp)<=10)' name: 'Exit Air Temp temperature lower non-critical on {HOSTNAME}' priority: AVERAGE - uuid: 4219e36dfebe4d9ca78096c7480fdbcb expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.exit.air.temp)>=85) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.exit.air.temp)>=80)' name: 'Exit Air Temp temperature upper critical on {HOSTNAME}' priority: HIGH - uuid: 84d216100dd7412c988b95aed82b2211 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.exit.air.temp)>=80) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.exit.air.temp)>=75)' name: 'Exit Air Temp temperature upper non-critical on {HOSTNAME}' priority: AVERAGE - uuid: e2a57f183db642038a6b571a4dabfc04 name: 'Fan 1 Present' type: IPMI key: ipmi.fan.1.present delay: '300' history: 7d ipmi_sensor: 'Fan 1 Present0' preprocessing: - type: HEX_TO_DECIMAL parameters: - '' tags: - tag: Application value: 'Fan Sensors' triggers: - uuid: 3dcd578463514a68b2f1c84a3fe70d45 expression: last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.fan.1.present)<>2 name: 'Fan 1 Present status changed on {HOSTNAME}' priority: HIGH - uuid: e21eb662d62a42b7b7ab7df29b657153 name: 'Fan 2 Present' type: IPMI key: ipmi.fan.2.present delay: '300' history: 7d ipmi_sensor: 'Fan 2 Present0' preprocessing: - type: HEX_TO_DECIMAL parameters: - '' tags: - tag: Application value: 'Fan Sensors' triggers: - uuid: d2c32f04e1274cf6b304fb4803bc2f8c expression: last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.fan.2.present)<>2 name: 'Fan 2 Present status changed on {HOSTNAME}' priority: HIGH - uuid: e28c837ff86047c59d771eed13f3d3dc name: 'Fan 3 Present' type: IPMI key: ipmi.fan.3.present delay: '300' history: 7d ipmi_sensor: 'Fan 3 Present0' preprocessing: - type: HEX_TO_DECIMAL parameters: - '' tags: - tag: Application value: 'Fan Sensors' triggers: - uuid: 0cde3f2b184e493fa6f5dd24b762c20e expression: last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.fan.3.present)<>2 name: 'Fan 3 Present status changed on {HOSTNAME}' priority: HIGH - uuid: 8e8ac8f84cd0484faf4c463249e8cf1a name: 'Fan 4 Present' type: IPMI key: ipmi.fan.4.present delay: '300' history: 7d ipmi_sensor: 'Fan 4 Present0' preprocessing: - type: HEX_TO_DECIMAL parameters: - '' tags: - tag: Application value: 'Fan Sensors' triggers: - uuid: 345de40bd1e04528b3e61abb7e56a1a1 expression: last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.fan.4.present)<>2 name: 'Fan 4 Present status changed on {HOSTNAME}' priority: HIGH - uuid: d09693c6084341508e2e7021902e7656 name: 'Fan 5 Present' type: IPMI key: ipmi.fan.5.present delay: '300' history: 7d ipmi_sensor: 'Fan 5 Present0' preprocessing: - type: HEX_TO_DECIMAL parameters: - '' tags: - tag: Application value: 'Fan Sensors' triggers: - uuid: 19533b34c4d84e6295b6b3dee5266896 expression: last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.fan.5.present)<>2 name: 'Fan 5 Present status changed on {HOSTNAME}' priority: HIGH - uuid: 6138686c0a634f22971b34d509419b5b name: 'Fan Redundancy' type: IPMI key: ipmi.fan.redundancy delay: '300' history: 7d ipmi_sensor: 'Fan Redundancy0' preprocessing: - type: HEX_TO_DECIMAL parameters: - '' tags: - tag: Application value: 'Fan Sensors' triggers: - uuid: 9bce30634f4448e587912ad0d5cd1e26 expression: last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.fan.redundancy)<>1 name: 'Fan Redundancy status changed on {HOSTNAME}' priority: HIGH - uuid: 152d504288ac4a50b932e4f15f660bc5 name: 'Front Panel Temp' type: IPMI key: ipmi.front.panel.temp delay: '300' history: 7d units: C ipmi_sensor: 'Front Panel Temp' tags: - tag: Application value: 'Temperature Sensors' triggers: - uuid: 9cc5db2766194d4d9daa0cf2afa2d7f5 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.front.panel.temp)<=0) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.front.panel.temp)<=5)' name: 'Front Panel Temp temperature lower critical on {HOSTNAME}' priority: HIGH - uuid: aaf2049f75e6461883204f612b02694e expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.front.panel.temp)<=5) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.front.panel.temp)<=10)' name: 'Front Panel Temp temperature lower non-critical on {HOSTNAME}' priority: AVERAGE - uuid: d6172cedca78439090fcf834c98f6e16 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.front.panel.temp)>=65) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.front.panel.temp)>=60)' name: 'Front Panel Temp temperature upper critical on {HOSTNAME}' priority: HIGH - uuid: 5cca4a6209ee4050913f61824262178e expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.front.panel.temp)>=60) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.front.panel.temp)>=55)' name: 'Front Panel Temp temperature upper non-critical on {HOSTNAME}' priority: AVERAGE - uuid: 72de4fc325364587b36cddda28c30d56 name: 'HDD 0 Status' type: IPMI key: ipmi.hdd.0.status delay: '300' history: 7d ipmi_sensor: 'HDD 0 Status0' preprocessing: - type: HEX_TO_DECIMAL parameters: - '' tags: - tag: Application value: 'Drive Slot' triggers: - uuid: e096765baa1349b4ae7c1ea5a6f9a707 expression: last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.hdd.0.status)<>1 name: 'HDD 0 Status status changed on {HOSTNAME}' priority: HIGH - uuid: a3b088eca9f141fd916e131c10bbe0e0 name: 'HDD 1 Status' type: IPMI key: ipmi.hdd.1.status delay: '300' history: 7d ipmi_sensor: 'HDD 1 Status0' preprocessing: - type: HEX_TO_DECIMAL parameters: - '' tags: - tag: Application value: 'Drive Slot' triggers: - uuid: edabd8a61ea64e7c9ec677451a51a711 expression: last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.hdd.1.status)<>1 name: 'HDD 1 Status status changed on {HOSTNAME}' priority: HIGH - uuid: aee2b29bde9e4b52bd7fdbdc19a2aa6b name: 'HDD 2 Status' type: IPMI key: ipmi.hdd.2.status delay: '300' history: 7d ipmi_sensor: 'HDD 2 Status0' preprocessing: - type: HEX_TO_DECIMAL parameters: - '' tags: - tag: Application value: 'Drive Slot' triggers: - uuid: 26f9ef817ba84caab299074000a7a5a7 expression: last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.hdd.2.status)<>1 name: 'HDD 2 Status status changed on {HOSTNAME}' priority: HIGH - uuid: eed3289e31084b20a9efcf9c298b2111 name: 'HDD 3 Status' type: IPMI key: ipmi.hdd.3.status delay: '300' history: 7d ipmi_sensor: 'HDD 3 Status0' preprocessing: - type: HEX_TO_DECIMAL parameters: - '' tags: - tag: Application value: 'Drive Slot' triggers: - uuid: 4b7b9a4d2ffd4d84be0613fc3df35eab expression: last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.hdd.3.status)<>1 name: 'HDD 3 Status status changed on {HOSTNAME}' priority: HIGH - uuid: 8175cda26fad465e87720d53893ae4ae name: 'HDD 4 Status' type: IPMI key: ipmi.hdd.4.status delay: '300' history: 7d ipmi_sensor: 'HDD 4 Status0' preprocessing: - type: HEX_TO_DECIMAL parameters: - '' tags: - tag: Application value: 'Drive Slot' triggers: - uuid: 08d04baf5c42469eb85f1dfe2b79d2c0 expression: last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.hdd.4.status)<>1 name: 'HDD 4 Status status changed on {HOSTNAME}' priority: HIGH - uuid: 22bed58afb9e437c91985ac38fa769cc name: 'HDD 5 Status' type: IPMI key: ipmi.hdd.5.status delay: '300' history: 7d ipmi_sensor: 'HDD 5 Status0' preprocessing: - type: HEX_TO_DECIMAL parameters: - '' tags: - tag: Application value: 'Drive Slot' triggers: - uuid: 9fb1e32285484b74813977c13432ac9f expression: last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.hdd.5.status)<>1 name: 'HDD 5 Status status changed on {HOSTNAME}' priority: HIGH - uuid: e7cde73fecb247c5acb23e1b5b3f0849 name: 'HDD 6 Status' type: IPMI key: ipmi.hdd.6.status delay: '300' history: 7d ipmi_sensor: 'HDD 6 Status0' preprocessing: - type: HEX_TO_DECIMAL parameters: - '' tags: - tag: Application value: 'Drive Slot' triggers: - uuid: e09419e925364fb38156af6220c5854b expression: last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.hdd.6.status)<>1 name: 'HDD 6 Status status changed on {HOSTNAME}' priority: HIGH - uuid: 4ed2672cfa9847c8b573c1bcb671173f name: 'HDD 7 Status' type: IPMI key: ipmi.hdd.7.status delay: '300' history: 7d ipmi_sensor: 'HDD 7 Status0' preprocessing: - type: HEX_TO_DECIMAL parameters: - '' tags: - tag: Application value: 'Drive Slot' triggers: - uuid: e2bdc436dfca40eabe84fc350a9cdf47 expression: last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.hdd.7.status)<>1 name: 'HDD 7 Status status changed on {HOSTNAME}' priority: HIGH - uuid: 1396f691746e438991b1ad5ac0b8d2d2 name: 'HDD 8 Status' type: IPMI key: ipmi.hdd.8.status delay: '300' history: 7d ipmi_sensor: 'HDD 8 Status0' preprocessing: - type: HEX_TO_DECIMAL parameters: - '' tags: - tag: Application value: 'Drive Slot' triggers: - uuid: ff40702c9afc4d748b0288dd0b462ea9 expression: last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.hdd.8.status)<>1 name: 'HDD 8 Status status changed on {HOSTNAME}' priority: HIGH - uuid: 0877faaefd3d47f29a0f41885c147018 name: 'HDD 9 Status' type: IPMI key: ipmi.hdd.9.status delay: '300' history: 7d ipmi_sensor: 'HDD 9 Status0' preprocessing: - type: HEX_TO_DECIMAL parameters: - '' tags: - tag: Application value: 'Drive Slot' triggers: - uuid: a17f4c40221848c4aba269dbfd194622 expression: last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.hdd.9.status)<>1 name: 'HDD 9 Status status changed on {HOSTNAME}' priority: HIGH - uuid: 5a1bf148ebed4e4989b87dcd9e2de56f name: 'HDD 10 Status' type: IPMI key: ipmi.hdd.10.status delay: '300' history: 7d ipmi_sensor: 'HDD 10 Status0' preprocessing: - type: HEX_TO_DECIMAL parameters: - '' tags: - tag: Application value: 'Drive Slot' triggers: - uuid: e19157fa17724395b1050726fbfead74 expression: last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.hdd.10.status)<>1 name: 'HDD 10 Status status changed on {HOSTNAME}' priority: HIGH - uuid: d9a1ea789aa44acdafc89ff2fb745a8e name: 'HDD 11 Status' type: IPMI key: ipmi.hdd.11.status delay: '300' history: 7d ipmi_sensor: 'HDD 11 Status0' preprocessing: - type: HEX_TO_DECIMAL parameters: - '' tags: - tag: Application value: 'Drive Slot' triggers: - uuid: d2fea38cf8ac41c0a681f67b44ecd639 expression: last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.hdd.11.status)<>1 name: 'HDD 11 Status status changed on {HOSTNAME}' priority: HIGH - uuid: 52f2f40f4172463ba787c3f702780e50 name: 'HDD 12 Status' type: IPMI key: ipmi.hdd.12.status delay: '300' history: 7d ipmi_sensor: 'HDD 12 Status0' preprocessing: - type: HEX_TO_DECIMAL parameters: - '' tags: - tag: Application value: 'Drive Slot' triggers: - uuid: cd5fed0fe98447d5a47cee7dddd027fa expression: last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.hdd.12.status)<>1 name: 'HDD 12 Status status changed on {HOSTNAME}' priority: HIGH - uuid: 9b12b798ef234b4ca9cc2c3394987e3e name: 'HDD 13 Status' type: IPMI key: ipmi.hdd.13.status delay: '300' history: 7d ipmi_sensor: 'HDD 13 Status0' preprocessing: - type: HEX_TO_DECIMAL parameters: - '' tags: - tag: Application value: 'Drive Slot' triggers: - uuid: 933635b23e834580b98f24b5d0c46b20 expression: last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.hdd.13.status)<>1 name: 'HDD 13 Status status changed on {HOSTNAME}' priority: HIGH - uuid: 02fd64382a7d4c9989ed6096012b61e4 name: 'HDD 14 Status' type: IPMI key: ipmi.hdd.14.status delay: '300' history: 7d ipmi_sensor: 'HDD 14 Status0' preprocessing: - type: HEX_TO_DECIMAL parameters: - '' tags: - tag: Application value: 'Drive Slot' triggers: - uuid: 7a04541049db4faf95006b1d22e76c31 expression: last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.hdd.14.status)<>1 name: 'HDD 14 Status status changed on {HOSTNAME}' priority: HIGH - uuid: d5ca0a9a7fe4443e828296d648b7011e name: 'HDD 15 Status' type: IPMI key: ipmi.hdd.15.status delay: '300' history: 7d ipmi_sensor: 'HDD 15 Status0' preprocessing: - type: HEX_TO_DECIMAL parameters: - '' tags: - tag: Application value: 'Drive Slot' triggers: - uuid: dc26c16a7fb8435fb10ddbe797d61bb7 expression: last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.hdd.15.status)<>1 name: 'HDD 15 Status status changed on {HOSTNAME}' priority: HIGH - uuid: 1aa8dee00aa044bc8f7f76b66ea89157 name: 'HDD 16 Status' type: IPMI key: ipmi.hdd.16.status delay: '300' history: 7d ipmi_sensor: 'HDD 16 Status0' preprocessing: - type: HEX_TO_DECIMAL parameters: - '' tags: - tag: Application value: 'Drive Slot' triggers: - uuid: 30226d197f9c47e2b7acfad3a36e6065 expression: last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.hdd.16.status)<>1 name: 'HDD 16 Status status changed on {HOSTNAME}' priority: HIGH - uuid: cd706a9c853e40168a9b8fdac05f3744 name: 'HDD 17 Status' type: IPMI key: ipmi.hdd.17.status delay: '300' history: 7d ipmi_sensor: 'HDD 17 Status0' preprocessing: - type: HEX_TO_DECIMAL parameters: - '' tags: - tag: Application value: 'Drive Slot' triggers: - uuid: ca955b243fa0424cbb7bac5396719442 expression: last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.hdd.17.status)<>1 name: 'HDD 17 Status status changed on {HOSTNAME}' priority: HIGH - uuid: 62c5df93e4bc4876af9e13f61c0b1333 name: 'HDD 18 Status' type: IPMI key: ipmi.hdd.18.status delay: '300' history: 7d ipmi_sensor: 'HDD 18 Status0' preprocessing: - type: HEX_TO_DECIMAL parameters: - '' tags: - tag: Application value: 'Drive Slot' triggers: - uuid: 604d7591fab444638a0c7d1fc081b5a5 expression: last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.hdd.18.status)<>1 name: 'HDD 18 Status status changed on {HOSTNAME}' priority: HIGH - uuid: 6ab9cc8324864d72b9730dee09f9521b name: 'HDD 19 Status' type: IPMI key: ipmi.hdd.19.status delay: '300' history: 7d ipmi_sensor: 'HDD 19 Status0' preprocessing: - type: HEX_TO_DECIMAL parameters: - '' tags: - tag: Application value: 'Drive Slot' triggers: - uuid: d635bece3155477c9669a0a283640b2f expression: last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.hdd.19.status)<>1 name: 'HDD 19 Status status changed on {HOSTNAME}' priority: HIGH - uuid: beb98f9ba72b45d783f7b62d1d86dc2e name: 'HDD 20 Status' type: IPMI key: ipmi.hdd.20.status delay: '300' history: 7d ipmi_sensor: 'HDD 20 Status0' preprocessing: - type: HEX_TO_DECIMAL parameters: - '' tags: - tag: Application value: 'Drive Slot' triggers: - uuid: 403fff3496ec478e82dd64e65a3d6484 expression: last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.hdd.20.status)<>1 name: 'HDD 20 Status status changed on {HOSTNAME}' priority: HIGH - uuid: 90cbb03a2f5342b68776c4d442d5b967 name: 'HDD 21 Status' type: IPMI key: ipmi.hdd.21.status delay: '300' history: 7d ipmi_sensor: 'HDD 21 Status0' preprocessing: - type: HEX_TO_DECIMAL parameters: - '' tags: - tag: Application value: 'Drive Slot' triggers: - uuid: 141b58956f03412ea9f4c1618ce74b6a expression: last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.hdd.21.status)<>1 name: 'HDD 21 Status status changed on {HOSTNAME}' priority: HIGH - uuid: 84be0fcaa81343c898266cfbbebd4974 name: 'HDD 22 Status' type: IPMI key: ipmi.hdd.22.status delay: '300' history: 7d ipmi_sensor: 'HDD 22 Status0' preprocessing: - type: HEX_TO_DECIMAL parameters: - '' tags: - tag: Application value: 'Drive Slot' triggers: - uuid: 7bdf9f0fdc8d4b7aa6dca449d2c8ffbc expression: last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.hdd.22.status)<>1 name: 'HDD 22 Status status changed on {HOSTNAME}' priority: HIGH - uuid: 65fc08d79ffc46aa8f7ad18d35d62e05 name: 'HDD 23 Status' type: IPMI key: ipmi.hdd.23.status delay: '300' history: 7d ipmi_sensor: 'HDD 23 Status0' preprocessing: - type: HEX_TO_DECIMAL parameters: - '' tags: - tag: Application value: 'Drive Slot' triggers: - uuid: 387cbe4db4b742d09d0575063c1832a6 expression: last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.hdd.23.status)<>1 name: 'HDD 23 Status status changed on {HOSTNAME}' priority: HIGH - uuid: 12108fd9883f4d1096df7f6e53ea9605 name: 'HSBP 1 Temp' type: IPMI key: ipmi.hsbp.1.temp delay: '300' history: 7d units: C ipmi_sensor: 'HSBP 1 Temp' tags: - tag: Application value: 'Temperature Sensors' triggers: - uuid: e7bf1c5ee28245fe9d47c81a7f526cdd expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.hsbp.1.temp)<=0) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.hsbp.1.temp)<=5)' name: 'HSBP 1 Temp temperature lower critical on {HOSTNAME}' priority: HIGH - uuid: 3c6f115984dd4e89a5b11ac4e382f4ea expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.hsbp.1.temp)<=5) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.hsbp.1.temp)<=10)' name: 'HSBP 1 Temp temperature lower non-critical on {HOSTNAME}' priority: AVERAGE - uuid: 258deb0468e0460aafbde17080c4544c expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.hsbp.1.temp)>=115) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.hsbp.1.temp)>=110)' name: 'HSBP 1 Temp temperature upper critical on {HOSTNAME}' priority: HIGH - uuid: d1e081e4852d4358a0fbd1fb9eed6a27 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.hsbp.1.temp)>=110) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.hsbp.1.temp)>=105)' name: 'HSBP 1 Temp temperature upper non-critical on {HOSTNAME}' priority: AVERAGE - uuid: 1c529acb3b454d3689a62fda8e3ab86f name: 'HSBP 2 Temp' type: IPMI key: ipmi.hsbp.2.temp delay: '300' history: 7d units: C ipmi_sensor: 'HSBP 2 Temp' tags: - tag: Application value: 'Temperature Sensors' triggers: - uuid: 493163d95b5646e2b67d560ff0bcc9bc expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.hsbp.2.temp)<=0) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.hsbp.2.temp)<=5)' name: 'HSBP 2 Temp temperature lower critical on {HOSTNAME}' priority: HIGH - uuid: c14a6a77f91f4f31af652d6b93161149 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.hsbp.2.temp)<=5) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.hsbp.2.temp)<=10)' name: 'HSBP 2 Temp temperature lower non-critical on {HOSTNAME}' priority: AVERAGE - uuid: de607d69d5da4f218f8936d8c7159963 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.hsbp.2.temp)>=115) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.hsbp.2.temp)>=110)' name: 'HSBP 2 Temp temperature upper critical on {HOSTNAME}' priority: HIGH - uuid: 58aa618a569643ec8c043c9a8ea6d478 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.hsbp.2.temp)>=110) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.hsbp.2.temp)>=105)' name: 'HSBP 2 Temp temperature upper non-critical on {HOSTNAME}' priority: AVERAGE - uuid: f931f35d18fa40d8ba00834c24457a00 name: 'HSBP 3 Temp' type: IPMI key: ipmi.hsbp.3.temp delay: '300' history: 7d units: C ipmi_sensor: 'HSBP 3 Temp' tags: - tag: Application value: 'Temperature Sensors' triggers: - uuid: fedc40fe905c44c3a9d615dcd1ef96a8 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.hsbp.3.temp)<=0) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.hsbp.3.temp)<=5)' name: 'HSBP 3 Temp temperature lower critical on {HOSTNAME}' priority: HIGH - uuid: f00f9e5fa4a84d17a0d8c3d3887d1447 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.hsbp.3.temp)<=5) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.hsbp.3.temp)<=10)' name: 'HSBP 3 Temp temperature lower non-critical on {HOSTNAME}' priority: AVERAGE - uuid: 4a93010a7e6a4fdf8611acc2c97a87d1 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.hsbp.3.temp)>=115) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.hsbp.3.temp)>=110)' name: 'HSBP 3 Temp temperature upper critical on {HOSTNAME}' priority: HIGH - uuid: 0657257ea5044d8baafd2e3a11f5cc57 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.hsbp.3.temp)>=110) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.hsbp.3.temp)>=105)' name: 'HSBP 3 Temp temperature upper non-critical on {HOSTNAME}' priority: AVERAGE - uuid: ad97ac71d1ae488fb5f1e7971f34972c name: 'LAN NIC Temp' type: IPMI key: ipmi.lan.nic.temp delay: '300' history: 7d units: C ipmi_sensor: 'LAN NIC Temp' tags: - tag: Application value: 'Temperature Sensors' triggers: - uuid: 8448005fd3f84359937ca7d3b0df1906 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.lan.nic.temp)<=0) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.lan.nic.temp)<=5)' name: 'LAN NIC Temp temperature lower critical on {HOSTNAME}' priority: HIGH - uuid: ad34bba8d4b04b03a15c993ed5999574 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.lan.nic.temp)<=5) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.lan.nic.temp)<=10)' name: 'LAN NIC Temp temperature lower non-critical on {HOSTNAME}' priority: AVERAGE - uuid: 2f5e69ee91384959a0a9733ce8340a50 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.lan.nic.temp)>=120) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.lan.nic.temp)>=115)' name: 'LAN NIC Temp temperature upper critical on {HOSTNAME}' priority: HIGH - uuid: a76f364fb3464cc0a5071f4f9093e77a expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.lan.nic.temp)>=115) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.lan.nic.temp)>=110)' name: 'LAN NIC Temp temperature upper non-critical on {HOSTNAME}' priority: AVERAGE - uuid: cb1fb895d2574314888fc9a510bade1d name: 'P1 DTS Therm Mgn' type: IPMI key: ipmi.p1.dts.therm.mgn delay: '300' history: 7d value_type: FLOAT units: C ipmi_sensor: 'P1 DTS Therm Mgn' tags: - tag: Application value: 'Temperature Sensors' - uuid: e6530b4c69154a8caa592c29275cc093 name: 'P1 Therm Margin' type: IPMI key: ipmi.p1.therm.margin delay: '300' history: 7d value_type: FLOAT units: C ipmi_sensor: 'P1 Therm Margin' tags: - tag: Application value: 'Temperature Sensors' - uuid: 8a673a70fe7a4d65a3eda5c6da55405e name: 'P2 DTS Therm Mgn' type: IPMI key: ipmi.p2.dts.therm.mgn delay: '300' history: 7d value_type: FLOAT units: C ipmi_sensor: 'P2 DTS Therm Mgn' tags: - tag: Application value: 'Temperature Sensors' - uuid: 479ad151e8bc4542b7fec5a7122dcaca name: 'P2 Therm Margin' type: IPMI key: ipmi.p2.therm.margin delay: '300' history: 7d value_type: FLOAT units: C ipmi_sensor: 'P2 Therm Margin' tags: - tag: Application value: 'Temperature Sensors' - uuid: 4e44414742f04e73a41c9f7ca2adc3da name: Power type: IPMI key: ipmi.power delay: '300' history: 7d ipmi_sensor: power valuemap: name: 'Service state' preprocessing: - type: HEX_TO_DECIMAL parameters: - '' tags: - tag: Application value: 'Power Supply' triggers: - uuid: 983d396ac6fa44e399033602f5383c6e expression: last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.power)=0 name: 'Power status changed on {HOSTNAME}' priority: HIGH - uuid: 875cb6468d7945008d28f24ca05506f9 name: 'PS1 Curr Out %' type: IPMI key: ipmi.ps1.curr.out delay: '300' history: 7d units: '%' ipmi_sensor: 'PS1 Curr Out %' tags: - tag: Application value: 'Current Sensors' triggers: - uuid: 73e2f39e0638437185ac9095e8fb33fa expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.ps1.curr.out)>=100) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.ps1.curr.out)>=82)' name: 'PS1 curr out % percent upper critical on {HOSTNAME}' priority: HIGH - uuid: ab94644098ed42ec8109d522ac9081fd expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.ps1.curr.out)>=118) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.ps1.curr.out)>=100)' name: 'PS1 curr out % percent upper non-critical on {HOSTNAME}' priority: AVERAGE - uuid: 57bde0acbf214b73a5d6d64f99801996 name: 'PS1 Fan Fail' type: IPMI key: ipmi.ps1.fan.fail delay: '300' history: 7d ipmi_sensor: 'PS1 Fan Fail0' preprocessing: - type: HEX_TO_DECIMAL parameters: - '' tags: - tag: Application value: 'Fan Sensors' triggers: - uuid: 4cbce1209b3f47a1966b29c35515e5f7 expression: last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.ps1.fan.fail)<>0 name: 'PS1 Fan Fail status changed on {HOSTNAME}' priority: HIGH - uuid: 83508f0dc4e44fb3a7d5b8b05c3dac53 name: 'PS1 Input Power' type: IPMI key: ipmi.ps1.input.power delay: '300' history: 7d units: W ipmi_sensor: 'PS1 Input Power' tags: - tag: Application value: 'Other Units-based Sensor' triggers: - uuid: 0eec3d803f9a4d75839ace5a5bb013aa expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.ps1.input.power)>=868) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.ps1.input.power)>=816)' name: 'PS1 Input Power watts upper critical on {HOSTNAME}' priority: HIGH - uuid: 974394dd23f247fdbf97b4919cf78e7e expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.ps1.input.power)>=920) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.ps1.input.power)>=868)' name: 'PS1 Input Power watts upper non-critical on {HOSTNAME}' priority: AVERAGE - uuid: e5f6d2471dac488b8b54a6b7686b16e9 name: 'PS1 Status' type: IPMI key: ipmi.ps1.status delay: '300' history: 7d ipmi_sensor: 'PS1 Status0' preprocessing: - type: HEX_TO_DECIMAL parameters: - '' tags: - tag: Application value: 'Power Supply' triggers: - uuid: 63f2f69ff2044e5cbfed35c3ff7d72b5 expression: last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.ps1.status)=0 name: 'PS1 Status status changed on {HOSTNAME}' priority: HIGH - uuid: 09ff5696eddd45a7b8380e1cad4d34c7 name: 'PS1 Temperature' type: IPMI key: ipmi.ps1.temperature delay: '300' history: 7d units: C ipmi_sensor: 'PS1 Temperature' tags: - tag: Application value: 'Temperature Sensors' triggers: - uuid: a5897fc2926c4a588180aab3744c7451 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.ps1.temperature)>=70) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.ps1.temperature)>=65)' name: 'PS1 Temperature temperature upper critical on {HOSTNAME}' priority: HIGH - uuid: 8c55e7ae0cc041d089eb83032e486fb8 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.ps1.temperature)>=65) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.ps1.temperature)>=60)' name: 'PS1 Temperature temperature upper non-critical on {HOSTNAME}' priority: AVERAGE - uuid: 631bb81f5e4347aeb1162bf994402fc7 name: 'PS2 Curr Out %' type: IPMI key: ipmi.ps2.curr.out delay: '300' history: 7d units: '%' ipmi_sensor: 'PS2 Curr Out %' tags: - tag: Application value: 'Current Sensors' triggers: - uuid: df389e2f30914de5bfb0f38e28a93e7e expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.ps2.curr.out)>=100) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.ps2.curr.out)>=82)' name: 'PS2 curr out % percent upper critical on {HOSTNAME}' priority: HIGH - uuid: 0dcaa770144f444387b923080ecc829d expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.ps2.curr.out)>=118) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.ps2.curr.out)>=100)' name: 'PS2 curr out % percent upper non-critical on {HOSTNAME}' priority: AVERAGE - uuid: 9a058a9165284d21972f378c332f46cc name: 'PS2 Fan Fail' type: IPMI key: ipmi.ps2.fan.fail delay: '300' history: 7d ipmi_sensor: 'PS2 Fan Fail0' preprocessing: - type: HEX_TO_DECIMAL parameters: - '' tags: - tag: Application value: 'Fan Sensors' triggers: - uuid: b03cfe8852c04ed0ab0d0455d5715958 expression: last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.ps2.fan.fail)<>0 name: 'PS2 Fan Fail status changed on {HOSTNAME}' priority: HIGH - uuid: 47c3ecc4cf0340e59643cd89b293918c name: 'PS2 Input Power' type: IPMI key: ipmi.ps2.input.power delay: '300' history: 7d units: W ipmi_sensor: 'PS2 Input Power' tags: - tag: Application value: 'Other Units-based Sensor' triggers: - uuid: 6dd60bbd4fd14384a31dbae442b23fd6 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.ps2.input.power)>=868) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.ps2.input.power)>=816)' name: 'PS2 Input Power watts upper critical on {HOSTNAME}' priority: HIGH - uuid: 999e925136814b2299b3b798c609fd59 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.ps2.input.power)>=920) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.ps2.input.power)>=868)' name: 'PS2 Input Power watts upper non-critical on {HOSTNAME}' priority: AVERAGE - uuid: d11ebb8d623445cfb82d46535d884b35 name: 'PS2 Status' type: IPMI key: ipmi.ps2.status delay: '300' history: 7d ipmi_sensor: 'PS2 Status0' preprocessing: - type: HEX_TO_DECIMAL parameters: - '' tags: - tag: Application value: 'Power Supply' triggers: - uuid: 7a13e68450914869b9a469701ac5b03e expression: last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.ps2.status)=0 name: 'PS2 Status status changed on {HOSTNAME}' priority: HIGH - uuid: 71021c93d83c4437a72ff1cdf77ce44d name: 'PS2 Temperature' type: IPMI key: ipmi.ps2.temperature delay: '300' history: 7d units: C ipmi_sensor: 'PS2 Temperature' tags: - tag: Application value: 'Temperature Sensors' triggers: - uuid: 6d0c289b8d3d400b815627d1873eb8b7 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.ps2.temperature)>=70) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.ps2.temperature)>=65)' name: 'PS2 Temperature temperature upper critical on {HOSTNAME}' priority: HIGH - uuid: 13a24ece599042f7aed4f68a0be2bf1b expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.ps2.temperature)>=65) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.ps2.temperature)>=60)' name: 'PS2 Temperature temperature upper non-critical on {HOSTNAME}' priority: AVERAGE - uuid: 4f202fe3bf2d45bca87ac40e2994e8b4 name: 'Pwr Unit Redund' type: IPMI key: ipmi.pwr.unit.redund delay: '300' history: 7d ipmi_sensor: 'Pwr Unit Redund0' preprocessing: - type: HEX_TO_DECIMAL parameters: - '' tags: - tag: Application value: 'Power Unit' triggers: - uuid: 8afae0c0c5374391a98d9c81740b4d94 expression: last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.pwr.unit.redund)=0 name: 'Pwr Unit Redund status changed on {HOSTNAME}' priority: HIGH - uuid: 4457aa6e61bb45679dfd95e6f8f1411f name: 'System Airflow' type: IPMI key: ipmi.system.airflow delay: '300' history: 7d units: CFM ipmi_sensor: 'System Airflow' tags: - tag: Application value: 'Other Units-based Sensor' - uuid: 195f14c071484d38b2c99a636f7cacbc name: 'System Fan 1' type: IPMI key: ipmi.system.fan.1 delay: '300' history: 7d units: RPM ipmi_sensor: 'System Fan 1' tags: - tag: Application value: 'Fan Sensors' triggers: - uuid: 9883d6ee7a1e4d55b708f533077410c9 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.system.fan.1)<=1715) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.system.fan.1)<=1960)' name: 'System Fan 1 RPM lower critical on {HOSTNAME}' priority: HIGH - uuid: 4fb4b033b8074474bcce0225478b025a expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.system.fan.1)<=1960) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.system.fan.1)<=2205)' name: 'System Fan 1 RPM lower non-critical on {HOSTNAME}' priority: AVERAGE - uuid: cdfcc2d4aa8b4651b195e8468d9a308c name: 'System Fan 2' type: IPMI key: ipmi.system.fan.2 delay: '300' history: 7d units: RPM ipmi_sensor: 'System Fan 2' tags: - tag: Application value: 'Fan Sensors' triggers: - uuid: 163149181b514aa0a95472ae4f35be21 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.system.fan.2)<=1715) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.system.fan.2)<=1960)' name: 'System Fan 2 RPM lower critical on {HOSTNAME}' priority: HIGH - uuid: a178b6df92f14f8c98d64b405f6906b7 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.system.fan.2)<=1960) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.system.fan.2)<=2205)' name: 'System Fan 2 RPM lower non-critical on {HOSTNAME}' priority: AVERAGE - uuid: 847fea9c8a154cbb812493f5506e4f7e name: 'System Fan 3' type: IPMI key: ipmi.system.fan.3 delay: '300' history: 7d units: RPM ipmi_sensor: 'System Fan 3' tags: - tag: Application value: 'Fan Sensors' triggers: - uuid: e0edf89d477544dc837e93e6b3b8d779 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.system.fan.3)<=1715) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.system.fan.3)<=1960)' name: 'System Fan 3 RPM lower critical on {HOSTNAME}' priority: HIGH - uuid: 35fb29205d64403cb3a0172b9c97049f expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.system.fan.3)<=1960) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.system.fan.3)<=2205)' name: 'System Fan 3 RPM lower non-critical on {HOSTNAME}' priority: AVERAGE - uuid: f64aaf51f8b94f91b26735221914a959 name: 'System Fan 4' type: IPMI key: ipmi.system.fan.4 delay: '300' history: 7d units: RPM ipmi_sensor: 'System Fan 4' tags: - tag: Application value: 'Fan Sensors' triggers: - uuid: f377a79c185f41c2b5e6a244e75ff4f7 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.system.fan.4)<=1715) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.system.fan.4)<=1960)' name: 'System Fan 4 RPM lower critical on {HOSTNAME}' priority: HIGH - uuid: 2cf07b38180b4a9cab8dc15116c8a628 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.system.fan.4)<=1960) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.system.fan.4)<=2205)' name: 'System Fan 4 RPM lower non-critical on {HOSTNAME}' priority: AVERAGE - uuid: 42a11f953eee47379a32f3224dc8b134 name: 'System Fan 5' type: IPMI key: ipmi.system.fan.5 delay: '300' history: 7d units: RPM ipmi_sensor: 'System Fan 5' tags: - tag: Application value: 'Fan Sensors' triggers: - uuid: f28531f0b3a741a08123d497154fb9fc expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.system.fan.5)<=1715) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.system.fan.5)<=1960)' name: 'System Fan 5 RPM lower critical on {HOSTNAME}' priority: HIGH - uuid: 847ee17d77b34651912177de9dfbad01 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.system.fan.5)<=1960) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.system.fan.5)<=2205)' name: 'System Fan 5 RPM lower non-critical on {HOSTNAME}' priority: AVERAGE valuemaps: - uuid: 2e4133cd09ae4abd8e3d8ec8263d6e48 name: 'Service state' mappings: - value: '0' newvalue: Down - value: '1' newvalue: Up triggers: - uuid: 42c03debd74d48e7830037bcf5db953b expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.system.fan.3)<=1715) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.system.fan.2)<=1960)' name: 'System Fan 3 RPM lower critical on {HOSTNAME}' priority: HIGH - uuid: 40a67f46007248a5b0dea96288bb9648 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.system.fan.3)<=1960) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.system.fan.2)<=2205)' name: 'System Fan 3 RPM lower non-critical on {HOSTNAME}' priority: AVERAGE - uuid: 891a405babe6464dbf63a83e73e95143 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.system.fan.4)<=1715) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.system.fan.2)<=1960)' name: 'System Fan 4 RPM lower critical on {HOSTNAME}' priority: HIGH - uuid: 1e5df41afdc44d24bf5e39bb78d2a2b4 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.system.fan.4)<=1960) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.system.fan.2)<=2205)' name: 'System Fan 4 RPM lower non-critical on {HOSTNAME}' priority: AVERAGE - uuid: e6b3b305e5954a3f9c4badff4f2675d9 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.system.fan.5)<=1715) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.system.fan.2)<=1960)' name: 'System Fan 5 RPM lower critical on {HOSTNAME}' priority: HIGH - uuid: 1f3d6d6774774680a131cf0521fad116 expression: '({TRIGGER.VALUE}=0 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.system.fan.5)<=1960) or ({TRIGGER.VALUE}=1 and last(/UNISIM_IPMI_SGI_Altix_ISS3114/ipmi.system.fan.2)<=2205)' name: 'System Fan 5 RPM lower non-critical on {HOSTNAME}' priority: AVERAGE