5.02021-11-25T12:36:00ZTemplates/ModulesModule Generic SNMPv2 to Fuji IRMCModule Generic SNMPv2 to Fuji IRMCTemplate Module ICMP PingTemplates/ModulesGeneral- SNMP traps (fallback)SNMP_TRAPsnmptrap.fallback5m2w0LOGItem is used to collect all SNMP traps unmatched by other snmptrap itemsGeneralhh:mm:sszyyyy/MM/dd
- Device contact detailsSNMP_AGENT1.3.6.1.2.1.1.4.0system.contact1h2w0CHARMIB: SNMPv2-MIB
The textual identification of the contact person for this managed node, together with information on how to contact this person. If no contact information is known, the value is the zero-length string.CONTACTGeneral
- Device descriptionSNMP_AGENT1.3.6.1.2.1.1.1.0system.descr1h2w0CHARMIB: SNMPv2-MIB
A textual description of the entity. This value should
include the full name and version identification of the system's hardware type, software operating-system, and
networking software.HARDWAREGeneral
- Device locationSNMP_AGENT1.3.6.1.2.1.1.6.0system.location1h2w0CHARMIB: SNMPv2-MIB
The physical location of this node (e.g., `telephone closet, 3rd floor'). If the location is unknown, the value is the zero-length string.LOCATIONGeneral
- Device nameSNMP_AGENT1.3.6.1.2.1.1.5.0system.name1h2w0CHARMIB: SNMPv2-MIB
An administratively-assigned name for this managed node.By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is the zero-length string.NAMEGeneral
- System object IDSNMP_AGENT1.3.6.1.2.1.1.2.0system.objectid1h2w0CHARMIB: SNMPv2-MIB
The vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining`what kind of box' is being managed. For example, if vendor`Flintstones, Inc.' was assigned the subtree1.3.6.1.4.1.4242, it could assign the identifier 1.3.6.1.4.1.4242.1.1 to its `Fred Router'.General
- Device uptimeSNMP_AGENT1.3.6.1.2.1.1.3.0system.uptime[sysUpTime]30s2w0duptimeMIB: SNMPv2-MIB
The time (in hundredths of a second) since the network management portion of the system was last re-initialized.StatusMULTIPLIER0.01{last()}<10m{HOST.NAME} has been restartedWARNINGLast value: {ITEM.LASTVALUE1}.
The device uptime is less than 10 minutesYESNo SNMP data collection{Module Generic SNMPv2 to Fuji IRMC:zabbix[host,snmp,available].max({$SNMP_TIMEOUT})}=0
- SNMP availabilityINTERNALzabbix[host,snmp,available]2w0dStatuszabbix.host.available{max({$SNMP_TIMEOUT})}=0No SNMP data collectionWARNINGLast value: {ITEM.LASTVALUE1}.
SNMP is not available for polling. Please check device connectivity and SNMP settings.Unavailable by ICMP ping{Module Generic SNMPv2 to Fuji IRMC:icmpping.max(#3)}=0
Components errorsSNMP_AGENTdiscovery[{#NAME},1.3.6.1.4.1.231.2.10.2.11.4.1.1.5, {#STATUS}, 1.3.6.1.4.1.231.2.10.2.11.4.1.1.6]components.errors.discovery15mComponents {#NAME} - ErrorsSNMP_AGENT1.3.6.1.4.1.231.2.10.2.11.4.1.1.6.{#SNMPINDEX}component.errors.[{#SNMPINDEX}]30sGeneralSystem{min(15)}>1{HOST.NAME} -> Component {#NAME} Errors: {ITEM.LASTVALUE}HIGHYESComponents statusSNMP_AGENTdiscovery[{#NAME},1.3.6.1.4.1.231.2.10.2.11.4.1.1.2, {#STATUS}, 1.3.6.1.4.1.231.2.10.2.11.4.1.1.3]components.status.discovery15mComponent {#NAME} - StatusSNMP_AGENT1.3.6.1.4.1.231.2.10.2.11.4.1.1.3.{#SNMPINDEX}component.status.[{#SNMPINDEX}]30sSystemRX2540{last()}<>1 and {last()}<>6{HOST.NAME} -> {#NAME} status is failHIGHYESFans StatusSNMP_AGENTdiscovery[{#FAN}, .1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.3.1, {#FAN_SPEED}, .1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.6.1, {#STATUS}, .1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.5.1]snmp.discovery.fans15m{#FAN} - SpeedSNMP_AGENT.1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.6.1.{#SNMPINDEX}fan.speed.[{#SNMPINDEX}]30sFans{max(5)}<{$FAN_SPEED_LIMIT}{HOST.NAME} -> {#FAN} Speed: {ITEM.LASTVALUE}, threshold: {$FAN_SPEED_LIMIT}HIGH{#FAN} - StatusSNMP_AGENT.1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.5.1.{#SNMPINDEX}fan.status.[{#SNMPINDEX}]30sFansFujitsu RX FAN Status{last()}<>3{HOST.NAME} ->{#FAN} Status not okHIGHYESPSU StatusSNMP_AGENTdiscovery[{#PSU},1.3.6.1.4.1.231.2.10.2.2.10.6.2.1.4.1, {#PSU_STATUS}, 1.3.6.1.4.1.231.2.10.2.2.10.6.2.1.5.1]snmp.discovery.psu15m{#PSU} - StatusSNMP_AGENT1.3.6.1.4.1.231.2.10.2.2.10.6.2.1.5.1.{#SNMPINDEX}psu.status.[{#PSU}]30sPSUFujitsu RX PSU Status{last()}<>3{HOST.NAME} -> {#PSU} not okHIGHYESTemperatureSNMP_AGENTdiscovery[{#SENSOR},1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.4.1, {#SENSOR_TEMP}, 1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.6.1, {#WARN_TEMP}, 1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.7.1]snmp.discovery.temp15m{#SENSOR_TEMP}^\d\dA{#SENSOR} - TemperatureSNMP_AGENT1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.6.1.{#SNMPINDEX}sensor.temp.[{#SNMPINDEX}]30sFLOATCTemperature{last()}>{#WARN_TEMP}{HOST.NAME} -> Temperature {#SENSOR}: {ITEM.LASTVALUE}, threshold: {#WARN_TEMP}HIGHYESVoltageSNMP_AGENTdiscovery[{#VSENSOR},1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.3.1, {#VOLTAGE}, 1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.4.1]snmp.discovery.vsensors15m{#VSENSOR} - StatusSNMP_AGENT1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.4.1.{#SNMPINDEX}voltage.sensor.[{#SNMPINDEX}]30sVoltageFujitsu RX Voltage Status{last()}<>3 and {last()}<>2{HOST.NAME} -> {#VSENSOR} status not okHIGHYES{$SNMP_TIMEOUT}3mTemplate Module ICMP PingTemplate Module ICMP PingTemplate Module ICMP Ping version: 0.12Templates/ModulesStatus- ICMP pingSIMPLEicmpping601wStatusService state{max(#3)}=0Unavailable by ICMP pingHIGHLast value: {ITEM.LASTVALUE1}.
Last three attempts returned timeout. Please check device connectivity.
- ICMP lossSIMPLEicmppingloss601wFLOAT%Status{min(5m)}>{$ICMP_LOSS_WARN} and {min(5m)}<100High ICMP ping lossWARNINGUnavailable by ICMP ping{Template Module ICMP Ping:icmpping.max(#3)}=0
- ICMP response timeSIMPLEicmppingsec601wFLOATsStatus{avg(5m)}>{$ICMP_RESPONSE_TIME_WARN}High ICMP ping response timeWARNINGHigh ICMP ping loss{Template Module ICMP Ping:icmppingloss.min(5m)}>{$ICMP_LOSS_WARN} and {Template Module ICMP Ping:icmppingloss.min(5m)}<100Unavailable by ICMP ping{Template Module ICMP Ping:icmpping.max(#3)}=0
{$ICMP_LOSS_WARN}20{$ICMP_RESPONSE_TIME_WARN}0.15Fujitsu RX FAN Status1unknown2disabled3ok4failed5prefailure-predicted6redundant-fan-failed7not-manageable8not-presentFujitsu RX PSU Status1unknown2not-present3ok4failed5ac-fail6dc-fail7critical-temperature8not-manageable9fan-failure-predicted10fan-failure11power-safe-mode12non-redundant-dc-fail13non-redundant-ac-failFujitsu RX Voltage Status1unknown2not-available3ok4too-low5too-high6out-of-range7warningRX25401Ok6notPresentService state0Down1Upzabbix.host.available0not available1available2unknown