zabbix_export: version: '6.0' date: '2021-11-25T12:35:59Z' groups: - uuid: 57b7ae836ca64446ba2c296389c009b7 name: Templates/Modules templates: - uuid: c9ce7ac2fa684fc9967f1bf2be9fcd81 template: 'Module Generic SNMPv2 to Fuji IRMC' name: 'Module Generic SNMPv2 to Fuji IRMC' templates: - name: 'Template Module ICMP Ping' groups: - name: Templates/Modules items: - uuid: 9e1c8763edc047edaac82e013fa2e0f8 name: 'SNMP traps (fallback)' type: SNMP_TRAP key: snmptrap.fallback delay: 5m history: 2w trends: '0' value_type: LOG description: 'Item is used to collect all SNMP traps unmatched by other snmptrap items' logtimefmt: 'hh:mm:sszyyyy/MM/dd' tags: - tag: Application value: General - uuid: 30397ef21be6427ebf42c7b6488116c8 name: 'Device contact details' type: SNMP_AGENT snmp_oid: 1.3.6.1.2.1.1.4.0 key: system.contact delay: 1h history: 2w trends: '0' value_type: CHAR description: | MIB: SNMPv2-MIB The textual identification of the contact person for this managed node, together with information on how to contact this person. If no contact information is known, the value is the zero-length string. inventory_link: CONTACT tags: - tag: Application value: General - uuid: e0f2880c48e44e0e897ab736ff441c5b name: 'Device description' type: SNMP_AGENT snmp_oid: 1.3.6.1.2.1.1.1.0 key: system.descr delay: 1h history: 2w trends: '0' value_type: CHAR description: | MIB: SNMPv2-MIB A textual description of the entity. This value should include the full name and version identification of the system's hardware type, software operating-system, and networking software. inventory_link: HARDWARE tags: - tag: Application value: General - uuid: 7a92cc3ba81b4ac69ddd47f48e996b82 name: 'Device location' type: SNMP_AGENT snmp_oid: 1.3.6.1.2.1.1.6.0 key: system.location delay: 1h history: 2w trends: '0' value_type: CHAR description: | MIB: SNMPv2-MIB The physical location of this node (e.g., `telephone closet, 3rd floor'). If the location is unknown, the value is the zero-length string. inventory_link: LOCATION tags: - tag: Application value: General - uuid: 2cf67930cfc94f7d9f3c86aae45ab2af name: 'Device name' type: SNMP_AGENT snmp_oid: 1.3.6.1.2.1.1.5.0 key: system.name delay: 1h history: 2w trends: '0' value_type: CHAR description: | MIB: SNMPv2-MIB An administratively-assigned name for this managed node.By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is the zero-length string. inventory_link: NAME tags: - tag: Application value: General - uuid: 54d73d6cfba2440988dfa500c432f1e4 name: 'System object ID' type: SNMP_AGENT snmp_oid: 1.3.6.1.2.1.1.2.0 key: system.objectid delay: 1h history: 2w trends: '0' value_type: CHAR description: | MIB: SNMPv2-MIB The vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining`what kind of box' is being managed. For example, if vendor`Flintstones, Inc.' was assigned the subtree1.3.6.1.4.1.4242, it could assign the identifier 1.3.6.1.4.1.4242.1.1 to its `Fred Router'. tags: - tag: Application value: General - uuid: 7552e3d84dcf404ab0bdb1bc9ae87e4a name: 'Device uptime' type: SNMP_AGENT snmp_oid: 1.3.6.1.2.1.1.3.0 key: 'system.uptime[sysUpTime]' delay: 30s history: 2w trends: 0d units: uptime description: | MIB: SNMPv2-MIB The time (in hundredths of a second) since the network management portion of the system was last re-initialized. preprocessing: - type: MULTIPLIER parameters: - '0.01' tags: - tag: Application value: Status triggers: - uuid: 020e4f1a2d1540b4ace1c385a79c2ac9 expression: 'last(/Module Generic SNMPv2 to Fuji IRMC/system.uptime[sysUpTime])<10m' name: '{HOST.NAME} has been restarted' priority: WARNING description: | Last value: {ITEM.LASTVALUE1}. The device uptime is less than 10 minutes manual_close: 'YES' dependencies: - name: 'No SNMP data collection' expression: 'max(/Module Generic SNMPv2 to Fuji IRMC/zabbix[host,snmp,available],{$SNMP_TIMEOUT})=0' - uuid: 1fb7d75bbe8d47eaa63679f3c56d8309 name: 'SNMP availability' type: INTERNAL key: 'zabbix[host,snmp,available]' history: 2w trends: 0d valuemap: name: zabbix.host.available tags: - tag: Application value: Status triggers: - uuid: 41f7493427ed4a0fae624ae400238f17 expression: 'max(/Module Generic SNMPv2 to Fuji IRMC/zabbix[host,snmp,available],{$SNMP_TIMEOUT})=0' name: 'No SNMP data collection' priority: WARNING description: | Last value: {ITEM.LASTVALUE1}. SNMP is not available for polling. Please check device connectivity and SNMP settings. dependencies: - name: 'Unavailable by ICMP ping' expression: 'max(/Module Generic SNMPv2 to Fuji IRMC/icmpping,#3)=0' discovery_rules: - uuid: 17365956318e40df922698f0a6dccc4b name: 'Components errors' type: SNMP_AGENT snmp_oid: 'discovery[{#NAME},1.3.6.1.4.1.231.2.10.2.11.4.1.1.5, {#STATUS}, 1.3.6.1.4.1.231.2.10.2.11.4.1.1.6]' key: components.errors.discovery delay: 15m item_prototypes: - uuid: d127666668734b7ea2aa29d1ae29ee60 name: 'Components {#NAME} - Errors' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.231.2.10.2.11.4.1.1.6.{#SNMPINDEX}' key: 'component.errors.[{#SNMPINDEX}]' delay: 30s tags: - tag: Application value: General - tag: Application value: System trigger_prototypes: - uuid: 94cc792b05cb46879c5e5133087428da expression: 'min(/Module Generic SNMPv2 to Fuji IRMC/component.errors.[{#SNMPINDEX}],15s)>1' name: '{HOST.NAME} -> Component {#NAME} Errors: {ITEM.LASTVALUE}' priority: HIGH manual_close: 'YES' - uuid: 86a84fed2630460ebd42400363f9bd28 name: 'Components status' type: SNMP_AGENT snmp_oid: 'discovery[{#NAME},1.3.6.1.4.1.231.2.10.2.11.4.1.1.2, {#STATUS}, 1.3.6.1.4.1.231.2.10.2.11.4.1.1.3]' key: components.status.discovery delay: 15m item_prototypes: - uuid: 0bd148b0f8bf430aa4931f6ac30d7dc4 name: 'Component {#NAME} - Status' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.231.2.10.2.11.4.1.1.3.{#SNMPINDEX}' key: 'component.status.[{#SNMPINDEX}]' delay: 30s valuemap: name: RX2540 tags: - tag: Application value: System trigger_prototypes: - uuid: 9f1502dded934aa2950dedff0c8eaba1 expression: 'last(/Module Generic SNMPv2 to Fuji IRMC/component.status.[{#SNMPINDEX}])<>1 and last(/Module Generic SNMPv2 to Fuji IRMC/component.status.[{#SNMPINDEX}])<>6' name: '{HOST.NAME} -> {#NAME} status is fail' priority: HIGH manual_close: 'YES' - uuid: f95c2826ce614aedbc520b1f85ee2ffd name: 'Fans Status' type: SNMP_AGENT snmp_oid: 'discovery[{#FAN}, .1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.3.1, {#FAN_SPEED}, .1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.6.1, {#STATUS}, .1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.5.1]' key: snmp.discovery.fans delay: 15m item_prototypes: - uuid: 351d2a13f1e54f10ae2c9bafc2bf8670 name: '{#FAN} - Speed' type: SNMP_AGENT snmp_oid: '.1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.6.1.{#SNMPINDEX}' key: 'fan.speed.[{#SNMPINDEX}]' delay: 30s tags: - tag: Application value: Fans trigger_prototypes: - uuid: 6ada7ca63f634813bc56742b1d96e3c8 expression: 'max(/Module Generic SNMPv2 to Fuji IRMC/fan.speed.[{#SNMPINDEX}],5s)<{$FAN_SPEED_LIMIT}' name: '{HOST.NAME} -> {#FAN} Speed: {ITEM.LASTVALUE}, threshold: {$FAN_SPEED_LIMIT}' priority: HIGH - uuid: d191d72b7d20440d8f186982fa02fd8c name: '{#FAN} - Status' type: SNMP_AGENT snmp_oid: '.1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.5.1.{#SNMPINDEX}' key: 'fan.status.[{#SNMPINDEX}]' delay: 30s valuemap: name: 'Fujitsu RX FAN Status' tags: - tag: Application value: Fans trigger_prototypes: - uuid: 32edaf1bbaa242809cad6097e2524ed6 expression: 'last(/Module Generic SNMPv2 to Fuji IRMC/fan.status.[{#SNMPINDEX}])<>3' name: '{HOST.NAME} ->{#FAN} Status not ok' priority: HIGH manual_close: 'YES' - uuid: f5e3dc22c45d48a586f7b89cdc4d4d2c name: 'PSU Status' type: SNMP_AGENT snmp_oid: 'discovery[{#PSU},1.3.6.1.4.1.231.2.10.2.2.10.6.2.1.4.1, {#PSU_STATUS}, 1.3.6.1.4.1.231.2.10.2.2.10.6.2.1.5.1]' key: snmp.discovery.psu delay: 15m item_prototypes: - uuid: fe20cf97c0d748fe90958b6492e8339c name: '{#PSU} - Status' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.231.2.10.2.2.10.6.2.1.5.1.{#SNMPINDEX}' key: 'psu.status.[{#PSU}]' delay: 30s valuemap: name: 'Fujitsu RX PSU Status' tags: - tag: Application value: PSU trigger_prototypes: - uuid: 805dacf4ff684a26b3b5356ccf33c6fc expression: 'last(/Module Generic SNMPv2 to Fuji IRMC/psu.status.[{#PSU}])<>3' name: '{HOST.NAME} -> {#PSU} not ok' priority: HIGH manual_close: 'YES' - uuid: 1d828b0cb7bf42c2a135638c8ba97722 name: Temperature type: SNMP_AGENT snmp_oid: 'discovery[{#SENSOR},1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.4.1, {#SENSOR_TEMP}, 1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.6.1, {#WARN_TEMP}, 1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.7.1]' key: snmp.discovery.temp delay: 15m filter: conditions: - macro: '{#SENSOR_TEMP}' value: ^\d\d formulaid: A item_prototypes: - uuid: 4087bffa3cf54cedb9f6e5634afedf6f name: '{#SENSOR} - Temperature' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.6.1.{#SNMPINDEX}' key: 'sensor.temp.[{#SNMPINDEX}]' delay: 30s value_type: FLOAT units: C tags: - tag: Application value: Temperature trigger_prototypes: - uuid: 18fd181ed7ad43daa15bf131a8ae42d7 expression: 'last(/Module Generic SNMPv2 to Fuji IRMC/sensor.temp.[{#SNMPINDEX}])>{#WARN_TEMP}' name: '{HOST.NAME} -> Temperature {#SENSOR}: {ITEM.LASTVALUE}, threshold: {#WARN_TEMP}' priority: HIGH manual_close: 'YES' - uuid: 65b0d48f326c4d5eaeadee73273a332c name: Voltage type: SNMP_AGENT snmp_oid: 'discovery[{#VSENSOR},1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.3.1, {#VOLTAGE}, 1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.4.1]' key: snmp.discovery.vsensors delay: 15m item_prototypes: - uuid: 51eba07cb5814baebc6852d548cec8ea name: '{#VSENSOR} - Status' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.4.1.{#SNMPINDEX}' key: 'voltage.sensor.[{#SNMPINDEX}]' delay: 30s valuemap: name: 'Fujitsu RX Voltage Status' tags: - tag: Application value: Voltage trigger_prototypes: - uuid: cc5012dd180e4e4ca49627561cffa79e expression: 'last(/Module Generic SNMPv2 to Fuji IRMC/voltage.sensor.[{#SNMPINDEX}])<>3 and last(/Module Generic SNMPv2 to Fuji IRMC/voltage.sensor.[{#SNMPINDEX}])<>2' name: '{HOST.NAME} -> {#VSENSOR} status not ok' priority: HIGH manual_close: 'YES' macros: - macro: '{$SNMP_TIMEOUT}' value: 3m valuemaps: - uuid: d74652cf0c6f48cd91a4d47d8dbeba74 name: 'Fujitsu RX FAN Status' mappings: - value: '1' newvalue: unknown - value: '2' newvalue: disabled - value: '3' newvalue: ok - value: '4' newvalue: failed - value: '5' newvalue: prefailure-predicted - value: '6' newvalue: redundant-fan-failed - value: '7' newvalue: not-manageable - value: '8' newvalue: not-present - uuid: 04ff716f12ac40e4b86cb913460f6b22 name: 'Fujitsu RX PSU Status' mappings: - value: '1' newvalue: unknown - value: '2' newvalue: not-present - value: '3' newvalue: ok - value: '4' newvalue: failed - value: '5' newvalue: ac-fail - value: '6' newvalue: dc-fail - value: '7' newvalue: critical-temperature - value: '8' newvalue: not-manageable - value: '9' newvalue: fan-failure-predicted - value: '10' newvalue: fan-failure - value: '11' newvalue: power-safe-mode - value: '12' newvalue: non-redundant-dc-fail - value: '13' newvalue: non-redundant-ac-fail - uuid: 37c61775940547969d0c2be9cad94f99 name: 'Fujitsu RX Voltage Status' mappings: - value: '1' newvalue: unknown - value: '2' newvalue: not-available - value: '3' newvalue: ok - value: '4' newvalue: too-low - value: '5' newvalue: too-high - value: '6' newvalue: out-of-range - value: '7' newvalue: warning - uuid: fcf984548bc44a499d043e63b44f5066 name: RX2540 mappings: - value: '1' newvalue: Ok - value: '6' newvalue: notPresent - uuid: 2719e39f729548b3b7839b5f8aff8fba name: zabbix.host.available mappings: - value: '0' newvalue: 'not available' - value: '1' newvalue: available - value: '2' newvalue: unknown - uuid: 37e5eb5606bc4abba66c8b20381a1e8a template: 'Template Module ICMP Ping' name: 'Template Module ICMP Ping' description: 'Template Module ICMP Ping version: 0.12' groups: - name: Templates/Modules items: - uuid: db5a94f6cea14deba957202b2f014469 name: 'ICMP ping' type: SIMPLE key: icmpping delay: '60' history: 1w valuemap: name: 'Service state' tags: - tag: Application value: Status triggers: - uuid: b030876299434f3ba43e11c584104a81 expression: 'max(/Template Module ICMP Ping/icmpping,#3)=0' name: 'Unavailable by ICMP ping' priority: HIGH description: | Last value: {ITEM.LASTVALUE1}. Last three attempts returned timeout. Please check device connectivity. - uuid: 04b21adaf422473a88df2c52786474ed name: 'ICMP loss' type: SIMPLE key: icmppingloss delay: '60' history: 1w value_type: FLOAT units: '%' tags: - tag: Application value: Status triggers: - uuid: 42c4b0310aaf4b9c8cb502542b7dea90 expression: 'min(/Template Module ICMP Ping/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Template Module ICMP Ping/icmppingloss,5m)<100' name: 'High ICMP ping loss' priority: WARNING dependencies: - name: 'Unavailable by ICMP ping' expression: 'max(/Template Module ICMP Ping/icmpping,#3)=0' - uuid: a79e33e5fd264725b934f603fa071555 name: 'ICMP response time' type: SIMPLE key: icmppingsec delay: '60' history: 1w value_type: FLOAT units: s tags: - tag: Application value: Status triggers: - uuid: 32b4d8f3eba34bd380803410111d4b7f expression: 'avg(/Template Module ICMP Ping/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN}' name: 'High ICMP ping response time' priority: WARNING dependencies: - name: 'High ICMP ping loss' expression: 'min(/Template Module ICMP Ping/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Template Module ICMP Ping/icmppingloss,5m)<100' - name: 'Unavailable by ICMP ping' expression: 'max(/Template Module ICMP Ping/icmpping,#3)=0' macros: - macro: '{$ICMP_LOSS_WARN}' value: '20' - macro: '{$ICMP_RESPONSE_TIME_WARN}' value: '0.15' valuemaps: - uuid: bdb5d65d925542eaa61c302dc40fbfe8 name: 'Service state' mappings: - value: '0' newvalue: Down - value: '1' newvalue: Up