zabbix_export: version: '5.4' date: '2021-11-21T21:56:20Z' groups: - uuid: dc579cd7a1a34222933f24f52a68bcd8 name: 'Linux servers' templates: - uuid: 1fe9aaa8ef064e39b0bfc1b5e114e254 template: H3C_basic_monitoring name: H3C_basic_monitoring description: | ## Description H3C server basic monitoring items ## Overview H3C zabbix基于SNMP的监控模板,适用于HDM版本为B03 H3C ZABBIX monitoring template based on SNMP ,for HDM version B03 ## Author yelin groups: - name: 'Linux servers' items: - uuid: 3ae67650774b4e5781aa656d1385da4b name: h3cInletTempReading type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.25506.13.1.2.1.1.11.2.0 key: h3cInletTempReading delay: 30s tags: - tag: Application value: temperature triggers: - uuid: e901235cec554fb2a27a17b2df8c185c expression: last(/H3C_basic_monitoring/h3cInletTempReading)>54 name: Inlet_Temp_Critical priority: HIGH - uuid: abbee1252f11494ea52a6f5dd52fc09c expression: last(/H3C_basic_monitoring/h3cInletTempReading)>52 name: Inlet_Temp_Major priority: AVERAGE - uuid: 216ff0cc640b49aca9952063bcfda0bb expression: last(/H3C_basic_monitoring/h3cInletTempReading)>50 name: Inlet_Temp_Minor priority: WARNING - uuid: 9a37bf7987074293a615a5b36e6d21df name: h3cOutletTempReading type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.25506.13.1.2.1.1.11.4.0 key: h3cOutletTempReading delay: 30s tags: - tag: Application value: temperature triggers: - uuid: 1adfe36b28734fa4bac3b9b06e334105 expression: last(/H3C_basic_monitoring/h3cOutletTempReading)>100 name: Outlet_Temp_Major priority: AVERAGE - uuid: 4b1a4051a7ce427f9cdf4ce760b04918 expression: last(/H3C_basic_monitoring/h3cOutletTempReading)>95 name: Outlet_Temp_Minor priority: WARNING - uuid: 894ef283b7624cb885cd42d51a6d6025 name: h3cPowerTotalCost type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.25506.13.1.2.1.1.7.1.3.0 key: h3cPowerTotalCost delay: 30s tags: - tag: Application value: power - uuid: 62043444191042bebd358c4f722db178 name: h3cSrvBiosVersion type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.25506.13.1.2.2.7.2.0 key: h3cSrvBiosVersion delay: 60s trends: '0' value_type: CHAR tags: - tag: Application value: fire_vision - uuid: 34835aa3993c42728fa08cbd48577217 name: h3cSrvHdmVersion type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.25506.13.1.2.2.7.1.0 key: h3cSrvHdmVersion delay: 60s trends: '0' value_type: CHAR tags: - tag: Application value: fire_vision discovery_rules: - uuid: d7ba1836b90048dc85b60464c5ccfc35 name: h3cCPUInfo_discovery type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE},.1.3.6.1.4.1.25506.13.1.2.1.1.1.1.1.2]' key: h3cCPUInfo_discovery delay: 30s item_prototypes: - uuid: a60fc7a88eae4facb516d345af125b07 name: 'CPU_[{#SNMPINDEX}]_PresentStatus' type: SNMP_AGENT snmp_oid: '.1.3.6.1.4.1.25506.13.1.2.1.1.1.1.1.13.{#SNMPINDEX}' key: 'CPUPresentStatus[{#SNMPINDEX}]' delay: 30s description: 'The present status of CPU associated with the ID.' tags: - tag: Application value: CPU trigger_prototypes: - uuid: 018f2d951f164689bd9d9dcd2651ff74 expression: 'last(/H3C_basic_monitoring/CPUPresentStatus[{#SNMPINDEX}])=0' recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'last(/H3C_basic_monitoring/CPUPresentStatus[{#SNMPINDEX}])=1' name: CPU_absense priority: WARNING - uuid: 5c472ffff1574b94b612337404d03eab name: 'CPU_[{#SNMPINDEX}]_Status' type: SNMP_AGENT snmp_oid: '.1.3.6.1.4.1.25506.13.1.2.1.1.1.1.1.6.{#SNMPINDEX}' key: 'CPUStatus[{#SNMPINDEX}]' delay: 30s description: 'The working status of the CPU associated with the ID' tags: - tag: Application value: CPU trigger_prototypes: - uuid: 1a726ff5f1e04c2e98719fe762a6cc26 expression: 'last(/H3C_basic_monitoring/CPUStatus[{#SNMPINDEX}])=0' recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'last(/H3C_basic_monitoring/CPUStatus[{#SNMPINDEX}])=1' name: CPUStatus_alarm priority: WARNING - uuid: 05080ad83c4d4a089791e80626bf62b3 name: h3cFan_discover type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE},.1.3.6.1.4.1.25506.13.1.2.1.1.10.1.1.4]' key: h3cFan_discover delay: 30s item_prototypes: - uuid: 870a660fb4884d0e91a5a4cc4c279ff8 name: 'FAN_[{#SNMPINDEX}]_PresentStatus' type: SNMP_AGENT snmp_oid: '.1.3.6.1.4.1.25506.13.1.2.1.1.10.1.1.6.{#SNMPINDEX}' key: 'FANPresentStatus[{#SNMPINDEX}]' delay: 30s tags: - tag: Application value: FAN trigger_prototypes: - uuid: c4cf659eb56b457191bf5095b2ab4bd6 expression: 'last(/H3C_basic_monitoring/FANPresentStatus[{#SNMPINDEX}])=0' recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'last(/H3C_basic_monitoring/FANPresentStatus[{#SNMPINDEX}])=1' name: FAN_Status_alarm priority: AVERAGE description: 'fan absence' - uuid: 601717eb8b40496795d3c3e2f10078c9 name: 'FAN_[{#SNMPINDEX}]_Speed' type: SNMP_AGENT snmp_oid: '.1.3.6.1.4.1.25506.13.1.2.1.1.10.1.1.5.{#SNMPINDEX}' key: 'FANSpeed[{#SNMPINDEX}]' delay: 30s units: RPM tags: - tag: Application value: FAN - uuid: b9448eb492a5462d8fe2ac6741c5f375 name: h3cFru_discovery type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE},.1.3.6.1.4.1.25506.13.1.2.1.3.1.1.4]' key: h3cFru_discovery delay: 30s item_prototypes: - uuid: f044835865844b4eb9bd84298fe9c4d5 name: 'Fru_[{#SNMPINDEX}]_Name' type: SNMP_AGENT snmp_oid: '.1.3.6.1.4.1.25506.13.1.2.1.3.1.1.4.{#SNMPINDEX}' key: 'FruName[{#SNMPINDEX}]' delay: 30s trends: '0' value_type: CHAR tags: - tag: Application value: FRU - uuid: ed5353f5f29944a48297b88f04971b16 name: h3cHardDiskInfo_discovery type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE},.1.3.6.1.4.1.25506.13.1.2.1.1.9.6.1.2]' key: h3cHardDiskInfo_discovery delay: 30s item_prototypes: - uuid: ad817b6992ed41ee94a380072f449fad name: 'HardDisk_[{#SNMPINDEX}]_HealthStatus' type: SNMP_AGENT snmp_oid: '.1.3.6.1.4.1.25506.13.1.2.1.1.9.6.1.3.{#SNMPINDEX}' key: 'HardDiskHealthStatus[{#SNMPINDEX}]' delay: 30s description: 'The hard disk health status' tags: - tag: Application value: HardDisk trigger_prototypes: - uuid: cc8bbcd8b0204e2cbace3857c3f15e27 expression: 'last(/H3C_basic_monitoring/HardDiskHealthStatus[{#SNMPINDEX}])>3' recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'last(/H3C_basic_monitoring/HardDiskHealthStatus[{#SNMPINDEX}])=2' name: HardDiskStatus_major priority: HIGH manual_close: 'YES' - uuid: b2f6e1119cb842cd8749c2b7a9f3a69b expression: 'last(/H3C_basic_monitoring/HardDiskHealthStatus[{#SNMPINDEX}])=3' recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'last(/H3C_basic_monitoring/HardDiskHealthStatus[{#SNMPINDEX}])=2' name: HardDiskStatus_minor priority: WARNING manual_close: 'YES' - uuid: 6558ce00e89e4e6db19785dd7bf64fae name: 'HardDisk_[{#SNMPINDEX}]_Location' type: SNMP_AGENT snmp_oid: '.1.3.6.1.4.1.25506.13.1.2.1.1.9.6.1.2.{#SNMPINDEX}' key: 'HardDiskStatus[{#SNMPINDEX}]' delay: 30s trends: '0' value_type: CHAR description: 'The location of hard disk' tags: - tag: Application value: HardDisk - uuid: 1140327c9fe74f7096fbd8839400cce5 name: h3cHealthInfo_discovery type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE},.1.3.6.1.4.1.25506.13.1.2.4.7.1]' key: h3cHealthInfo_discovery delay: 30s item_prototypes: - uuid: f6c4e7d730334cc5a2ac1d0d24ff2b11 name: 'h3cCPUHealthStatus[{#SNMPINDEX}]' type: SNMP_AGENT snmp_oid: '.1.3.6.1.4.1.25506.13.1.2.4.7.4.{#SNMPINDEX}' key: 'h3cCPUHealthStatus[{#SNMPINDEX}]' delay: 30s description: 'Health status of the CPU overall, normal(0), caution(1), warning(2), critical(3)' tags: - tag: Application value: health_status - uuid: 7edc9251e01c4f909114b3847262e1f1 name: 'h3cDiskHealthStatus[{#SNMPINDEX}]' type: SNMP_AGENT snmp_oid: '.1.3.6.1.4.1.25506.13.1.2.4.7.8.{#SNMPINDEX}' key: 'h3cDiskHealthStatus[{#SNMPINDEX}]' delay: 30s description: 'Health status of the disk overall, normal(0), caution(1), warning(2), critical(3)' tags: - tag: Application value: health_status - uuid: 42eb6804673543eca4acf3a63521661e name: 'h3cEntiretyHealthStatus[{#SNMPINDEX}]' type: SNMP_AGENT snmp_oid: '.1.3.6.1.4.1.25506.13.1.2.4.7.1.{#SNMPINDEX}' key: 'h3cEntiretyHealthStatus[{#SNMPINDEX}]' delay: 30s description: 'The entirety health status of this machine, normal(0), caution(1), warning(2), critical(3)' tags: - tag: Application value: health_status trigger_prototypes: - uuid: a811967caacd43859eefbe74d0ad1617 expression: 'last(/H3C_basic_monitoring/h3cEntiretyHealthStatus[{#SNMPINDEX}])=1' recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'last(/H3C_basic_monitoring/h3cEntiretyHealthStatus[{#SNMPINDEX}])=0' name: EntiretyHeathStatus_caution priority: WARNING - uuid: 51c442802bd146dbbf1526fad8ebbfe7 expression: 'last(/H3C_basic_monitoring/h3cEntiretyHealthStatus[{#SNMPINDEX}])=3' recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'last(/H3C_basic_monitoring/h3cEntiretyHealthStatus[{#SNMPINDEX}])=0' name: EntiretyHeathStatus_critical priority: HIGH - uuid: 532a0e1959e24c3e8d582dc634d748fa expression: 'last(/H3C_basic_monitoring/h3cEntiretyHealthStatus[{#SNMPINDEX}])=2' recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'last(/H3C_basic_monitoring/h3cEntiretyHealthStatus[{#SNMPINDEX}])=0' name: EntiretyHeathStatus_warning priority: AVERAGE - uuid: beb1d6deddbe443ba2bea52997500d13 name: 'h3cFanHealthStatus[{#SNMPINDEX}]' type: SNMP_AGENT snmp_oid: '.1.3.6.1.4.1.25506.13.1.2.4.7.3.{#SNMPINDEX}' key: 'h3cFanHealthStatus[{#SNMPINDEX}]' delay: 30s description: 'Health status of the FAN overall, normal(0), caution(1), warning(2), critical(3)' tags: - tag: Application value: health_status - uuid: 2b02a1ee56264a27a2f54a98dd4ac21d name: 'h3cMemHealthStatus[{#SNMPINDEX}]' type: SNMP_AGENT snmp_oid: '.1.3.6.1.4.1.25506.13.1.2.4.7.7.{#SNMPINDEX}' key: 'h3cMemHealthStatus[{#SNMPINDEX}]' delay: 30s description: 'Health status of the memory overall, normal(0), caution(1), warning(2), critical(3)' tags: - tag: Application value: health_status - uuid: ce550e3b0d254309b2209c048eb251ac name: 'h3cPwrHealthStatus[{#SNMPINDEX}]' type: SNMP_AGENT snmp_oid: '.1.3.6.1.4.1.25506.13.1.2.4.7.2.{#SNMPINDEX}' key: 'h3cPwrHealthStatus[{#SNMPINDEX}]' delay: 30s description: 'Health status of the power supply overall, normal(0), caution(1), warning(2), critical(3)' tags: - tag: Application value: health_status trigger_prototypes: - uuid: 30d1b83030f54e3cad780b70e15b0397 expression: 'last(/H3C_basic_monitoring/h3cPwrHealthStatus[{#SNMPINDEX}])=1' recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'last(/H3C_basic_monitoring/h3cPwrHealthStatus[{#SNMPINDEX}])=0' name: PwrHealthStatus_caution priority: WARNING manual_close: 'YES' - uuid: 5ccf8f3fd3f743fa9e6e16951ac7b109 expression: 'last(/H3C_basic_monitoring/h3cPwrHealthStatus[{#SNMPINDEX}])=2' recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'last(/H3C_basic_monitoring/h3cPwrHealthStatus[{#SNMPINDEX}])=0' name: PwrHealthStatus_warning priority: AVERAGE - uuid: db8661ea55704624868539b2dc71793d name: 'h3cTempHealthStatus[{#SNMPINDEX}]' type: SNMP_AGENT snmp_oid: '.1.3.6.1.4.1.25506.13.1.2.4.7.10.{#SNMPINDEX}' key: 'h3cTempHealthStatus[{#SNMPINDEX}]' delay: 30s description: 'Health status of the temprature overall, normal(0), caution(1), warning(2), critical(3)' tags: - tag: Application value: health_status - uuid: ba7048313de1483197fc5ccb1bb9e00d name: h3cMem_discovery type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE},.1.3.6.1.4.1.25506.13.1.2.1.1.2.2.1.5]' key: h3cMem_Discovery delay: 30s item_prototypes: - uuid: 82c6ea9f7eed4d0496071298fc4c9f07 name: 'Mem_[{#SNMPINDEX}]_Status' type: SNMP_AGENT snmp_oid: '.1.3.6.1.4.1.25506.13.1.2.1.1.2.2.1.5.{#SNMPINDEX}' key: 'MemStatus[{#SNMPINDEX}]' delay: 30s tags: - tag: Application value: Memory trigger_prototypes: - uuid: 4da32247e73a4ba2988f77f5b30c2117 expression: 'last(/H3C_basic_monitoring/MemStatus[{#SNMPINDEX}])>1' recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'last(/H3C_basic_monitoring/MemStatus[{#SNMPINDEX}])=1' name: MemStatus_alarm priority: WARNING - uuid: 03a45579c143413aa2b84a4d6dd6bbcb name: h3cPowerInfo_discovery type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE},.1.3.6.1.4.1.25506.13.1.2.1.1.7.1.1.1.2]' key: h3cPowerInfo_discovery delay: 30s item_prototypes: - uuid: eb864e98bfcd4d148adf0b4f5f05c5b4 name: 'Power_[{#SNMPINDEX}]_Cost' type: SNMP_AGENT snmp_oid: '.1.3.6.1.4.1.25506.13.1.2.1.1.7.1.1.1.10.{#SNMPINDEX}' key: 'PowerCost[{#SNMPINDEX}]' delay: 30s units: W description: 'Information about the cost of power. The unit is watt.' tags: - tag: Application value: power - uuid: 7f71922439a5425dab1d9f5224aef1db name: 'Power_[{#SNMPINDEX}]_PresnetStatus' type: SNMP_AGENT snmp_oid: '.1.3.6.1.4.1.25506.13.1.2.1.1.7.1.1.1.2.{#SNMPINDEX}' key: 'PowerPresnetStatus[{#SNMPINDEX}]' delay: 30s description: 'The present status of power supply , absence(0), presence(1)' tags: - tag: Application value: power trigger_prototypes: - uuid: 9f3513d2f4d0425480a3ec69c0f390d5 expression: 'last(/H3C_basic_monitoring/PowerPresnetStatus[{#SNMPINDEX}])=0' recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'last(/H3C_basic_monitoring/PowerPresnetStatus[{#SNMPINDEX}])=1' name: PowerPresentStatus_absense priority: INFO - uuid: 3454ca1d5d304017af2cbc0faa59f0ac name: h3cTempInfo_discovery type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE},.1.3.6.1.4.1.25506.13.1.2.1.1.11.3.1.4]' key: h3cTempInfo_discovery delay: 30s item_prototypes: - uuid: 6e93bf074dcb4d60b03c6c7bdaf492f2 name: 'TempSensor_[{#SNMPINDEX}]_Reading' type: SNMP_AGENT snmp_oid: '.1.3.6.1.4.1.25506.13.1.2.1.1.11.3.1.4.{#SNMPINDEX}' key: 'TempSensorReading[{#SNMPINDEX}]' delay: 30s value_type: FLOAT units: C description: 'Information about temperature reading, the unit is degree C.' tags: - tag: Application value: TempInfo - uuid: 7959e1061cb341119da01924a4d8d93c name: 'TempSensor_[{#SNMPINDEX}]_Status' type: SNMP_AGENT snmp_oid: '.1.3.6.1.4.1.25506.13.1.2.1.1.11.3.1.6.{#SNMPINDEX}' key: 'TempSensorStatus[{#SNMPINDEX}]' delay: 30s tags: - tag: Application value: TempInfo trigger_prototypes: - uuid: 96c8e93fa81e4d8ab8a35c74dddb43d0 expression: 'last(/H3C_basic_monitoring/TempSensorStatus[{#SNMPINDEX}])>2' recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'last(/H3C_basic_monitoring/TempSensorStatus[{#SNMPINDEX}])=2' name: TempSensorStatus_alarm priority: WARNING macros: - macro: '{$SNMP_COMMUNITY}' value: rocommstr graphs: - uuid: 5ca650cfb6b245859e4df62b3949d7c8 name: h3cPowerTotalCost graph_items: - color: 1A7C11 item: host: H3C_basic_monitoring key: h3cPowerTotalCost - uuid: 526508d618e94c689c6f8146ac2ce360 name: inlet_outlet_temperature graph_items: - color: 1A7C11 item: host: H3C_basic_monitoring key: h3cInletTempReading - sortorder: '1' color: F63100 item: host: H3C_basic_monitoring key: h3cOutletTempReading