zabbix_export: version: '6.0' date: '2021-11-21T21:51:38Z' groups: - uuid: 053f42c6bae3432cae270ea978f7e638 name: Fujitsu templates: - uuid: 40ceabe4f8ee47548afd55bb6e64e254 template: 'Fujitsu Primequest 3800E' name: 'Fujitsu Primequest 3800E' description: | ## Overview Value mapping Primequest 3800E - CPU 1 - unknown 2 - not-present 3 - ok 4 - disabled 5 - error 6 - failed 7 - missing-termination 8 - prefailed-warning Primequest 3800E - DIMM 1 - unknown 2 - not-present 3 - ok 4 - failed-disabled 5 - error 7 - warning 8 - hot-spare 9 - configuration-error Primequest 3800E - FAN 1 - unknown 2 - disabled 3 - ok 4 - failed 5 - prefailed-predicted 6 - redundant-fan-failed 7 - not-manageable 8 - not-present Primequest 3800E - FAN FAIL REACTION 1 - unknown 2 - continue 3 - shutdown-and-poweroff Primequest 3800E - OVERAL STATUS 1 - ok 2 - degraded 3 - error 4 - failed 5 - unknown Primequest 3800E - POWER SUPPLY 1 - unknown 2 - not-present 3 - ok 4 - failed 5 - ac-fail 6 - dc-fail 7 - critical-temperature 8 - not-manageable 9 - predictive-fail Primequest 3800E - TEMPERATURE 1 - unknown 2 - not-available 3 - ok 5 - failed 6 - temperature-warning 7 - temperature-critical Primequest 3800E - TEMPERATURE CRITICAL REACTION 1 - unknown 2 - continue 3 - shutdown-and-poweroff Primequest 3800E - VOLTAGE 1 - unknown 2 - not-available 3 - ok 4 - too-low 5 - too-high 6 - sensor-failed 7 - low-warning 8 - high-warning groups: - name: Fujitsu items: - uuid: 7f838aab31ec4f7f980c08bb240cba22 name: 'System exhaust airflow volume (m3/h)' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.211.1.31.1.1.1.5.3.1.2.1 key: afExhaustAirflowVolume value_type: FLOAT description: 'System exhaust airflow volume (''-1'' if value not available)' tags: - tag: Application value: Airflow - uuid: d653ae4e8b53432f82054a4f9b791a0b name: 'Overall status' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.211.1.31.1.1.1.8.1.0 key: agentStatus delay: 15s description: | Overall status of all monitored components in this agent ok(1):all subsystems and components working properly;no failure degraded(2):at least one component has a problem;system may still work properly error(3):severe problem;system will not work properly failed(4):one or more managed components have failed unknown(5):none of the subsystems had a valid status (e.g. during initialization) valuemap: name: 'Primequest 3800E - OVERAL STATUS' tags: - tag: Application value: 'Overal status' triggers: - uuid: 514d1a615f6c437f91d56c8570e9b1d6 expression: 'last(/Fujitsu Primequest 3800E/agentStatus)=2' name: 'Overal status Degraded' priority: WARNING - uuid: 48985aa0cc60477e9bcb679dfa8d573e expression: 'last(/Fujitsu Primequest 3800E/agentStatus)=3' name: 'Overal status Error' priority: AVERAGE - uuid: ff0afbeb5a47486886d0dea622a3739f expression: 'last(/Fujitsu Primequest 3800E/agentStatus)=4' name: 'Overal status Failed' priority: HIGH - uuid: f9975214876840c8afe43e1c0c8badb7 expression: 'last(/Fujitsu Primequest 3800E/agentStatus)=5' name: 'Overal status Unknown' priority: INFO - uuid: f7d5a00407904d149ed49235d436be93 name: 'System Power Consumption (W)' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.211.1.31.1.1.1.4.5.1.5.1 key: pmCurrentPowerConsumption delay: 60s value_type: FLOAT description: 'Current value of the system''s power consumption (in Watts;4294967295(0xffffffff) if value not available)' tags: - tag: Application value: Info - uuid: 7ac1af9ba32846c4bd3896074c1ba005 name: 'System Description' type: SNMP_AGENT snmp_oid: .1.3.6.1.2.1.1.1.0 key: sysDescr.0 delay: 1h trends: '0' value_type: TEXT tags: - tag: Application value: Info - uuid: 17165f259088414989afc7109c443df6 name: 'System Name' type: SNMP_AGENT snmp_oid: .1.3.6.1.2.1.1.5.0 key: sysName.0 delay: 1h trends: '0' value_type: TEXT tags: - tag: Application value: Info - uuid: f5c219bc399b4bb1929a4278de10c900 name: 'System Uptime' type: SNMP_AGENT snmp_oid: .1.3.6.1.2.1.1.3.0 key: sysUpTime.0 delay: 30s units: uptime tags: - tag: Application value: Info discovery_rules: - uuid: bbecb491a1934fd29a9dc4aebd4a65e7 name: 'Discover CPU' type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE}, .1.3.6.1.4.1.211.1.31.1.1.1.6.4.1.3]' key: cpus delay: 1h item_prototypes: - uuid: c17cdd37f2f446ebbfab82449ebc0c49 name: '{#SNMPVALUE} Status' type: SNMP_AGENT snmp_oid: '.1.3.6.1.4.1.211.1.31.1.1.1.6.4.1.4.{#SNMPINDEX}' key: 'cpus.4.[{#SNMPINDEX}]' delay: 15s description: | CPU status Status mapping. SEL level MIB Value Warning disabled(4) Warning prefailed-warning(8) Error failed(6) valuemap: name: 'Primequest 3800E - CPU' tags: - tag: Application value: CPU trigger_prototypes: - uuid: 6ee55e9d914249058e7ad97437211784 expression: 'last(/Fujitsu Primequest 3800E/cpus.4.[{#SNMPINDEX}])=6' name: '{#SNMPVALUE} Error' priority: HIGH - uuid: 5b584c35529f42f687828b7882e111f9 expression: 'last(/Fujitsu Primequest 3800E/cpus.4.[{#SNMPINDEX}])=4 or last(/Fujitsu Primequest 3800E/cpus.4.[{#SNMPINDEX}])=8' name: '{#SNMPVALUE} Warning' priority: AVERAGE - uuid: 97348c5b79134fb1977e032b68108e22 name: '{#SNMPVALUE} Model Name' type: SNMP_AGENT snmp_oid: '.1.3.6.1.4.1.211.1.31.1.1.1.6.4.1.5.{#SNMPINDEX}' key: 'cpus.5.[{#SNMPINDEX}]' delay: 10h trends: '0' status: DISABLED value_type: TEXT description: 'CPU model name (e.g. Itanium2 Processor)' tags: - tag: Application value: CPU - uuid: 00a78a1d467d462da41128ead5c763ab name: '{#SNMPVALUE} Step' type: SNMP_AGENT snmp_oid: '.1.3.6.1.4.1.211.1.31.1.1.1.6.4.1.7.{#SNMPINDEX}' key: 'cpus.7.[{#SNMPINDEX}]' delay: 10h trends: '0' value_type: TEXT description: 'CPU step / revision' tags: - tag: Application value: CPU - uuid: b7d868bfb97a480ab65f4884977a3429 name: '{#SNMPVALUE} Current Speed' type: SNMP_AGENT snmp_oid: '.1.3.6.1.4.1.211.1.31.1.1.1.6.4.1.8.{#SNMPINDEX}' key: 'cpus.8.[{#SNMPINDEX}]' delay: 10m description: 'CPU speed (frequency in MHz)' tags: - tag: Application value: CPU - uuid: bdae1942cfbd44f6ad9526c46cf6d62f name: '{#SNMPVALUE} Number of Cores' type: SNMP_AGENT snmp_oid: '.1.3.6.1.4.1.211.1.31.1.1.1.6.4.1.13.{#SNMPINDEX}' key: 'cpus.13.[{#SNMPINDEX}]' delay: 1h status: DISABLED description: 'Number of (physically available) cores within one physical CPU (for multi-core CPUs;platform dependent)' tags: - tag: Application value: CPU - uuid: c41d782d977742d3aa09aa21a18ebed0 name: '{#SNMPVALUE} Number of Enabled Cores' type: SNMP_AGENT snmp_oid: '.1.3.6.1.4.1.211.1.31.1.1.1.6.4.1.15.{#SNMPINDEX}' key: 'cpus.15.[{#SNMPINDEX}]' delay: 1h status: DISABLED description: 'Number of effectively enabled cores within one physical CPU (for multi-core CPUs;0 if unknown)' tags: - tag: Application value: CPU - uuid: 7a57eeaf4bc24ae1af25dcfb98687c8b name: 'Discover FAN' type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE}, .1.3.6.1.4.1.211.1.31.1.1.1.5.2.1.3]' key: fans delay: 1h item_prototypes: - uuid: 7e0db5a449c2463b848f42fde277d6cd name: '{#SNMPVALUE} Status' type: SNMP_AGENT snmp_oid: '.1.3.6.1.4.1.211.1.31.1.1.1.5.2.1.5.{#SNMPINDEX}' key: 'fans.5.[{#SNMPINDEX}]' history: 30d trends: 90d valuemap: name: 'Primequest 3800E - FAN' tags: - tag: Application value: Fans trigger_prototypes: - uuid: 9529e28b5d83497d9b876c8be1a0e75c expression: 'last(/Fujitsu Primequest 3800E/fans.5.[{#SNMPINDEX}])=5 or last(/Fujitsu Primequest 3800E/fans.5.[{#SNMPINDEX}])=4' name: '{#SNMPVALUE} Error' priority: HIGH - uuid: 8b5df4b11e1e444c910a81171e1ba04e name: '{#SNMPVALUE} Current Speed' type: SNMP_AGENT snmp_oid: '.1.3.6.1.4.1.211.1.31.1.1.1.5.2.1.6.{#SNMPINDEX}' key: 'fans.6.[{#SNMPINDEX}]' delay: 2m history: 30d trends: 90d value_type: FLOAT tags: - tag: Application value: Fans - uuid: 8b96218b7e0744edbec078967990fd56 name: '{#SNMPVALUE} Fail Reaction' type: SNMP_AGENT snmp_oid: '.1.3.6.1.4.1.211.1.31.1.1.1.5.2.1.8.{#SNMPINDEX}' key: 'fans.8.[{#SNMPINDEX}]' delay: 10h history: 30d trends: 90d valuemap: name: 'Primequest 3800E - FAN FAIL REACTION' tags: - tag: Application value: Fans graph_prototypes: - uuid: bab5492f1a3d4475b9859a417efd0ae0 name: '{#SNMPVALUE} Speed' graph_items: - color: 199C0D item: host: 'Fujitsu Primequest 3800E' key: 'fans.6.[{#SNMPINDEX}]' - uuid: 6ed0e10a359647318208354636824823 name: 'Discover DIMM' type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE}, .1.3.6.1.4.1.211.1.31.1.1.1.6.5.1.3]' key: memoryModules delay: 1h item_prototypes: - uuid: 6236bab8772d474bb57dee45c9274a5e name: '{#SNMPVALUE} Status' type: SNMP_AGENT snmp_oid: '.1.3.6.1.4.1.211.1.31.1.1.1.6.5.1.4.{#SNMPINDEX}' key: 'memoryModules.4.[{#SNMPINDEX}]' history: 30d trends: 90d value_type: FLOAT description: | Memory module status Status mapping. SEL level MIB Value Warning failed-disabled(4) Warning warning(7) Error error(5) Error configuration-error(9) valuemap: name: 'Primequest 3800E - DIMM' tags: - tag: Application value: Memory trigger_prototypes: - uuid: 37d1c3e43d19461082f038889430e1ac expression: 'last(/Fujitsu Primequest 3800E/memoryModules.4.[{#SNMPINDEX}])=5 or last(/Fujitsu Primequest 3800E/memoryModules.4.[{#SNMPINDEX}])=9' name: '{#SNMPVALUE} Error' priority: HIGH - uuid: 7d052faed4db4c77b1ff69529bb036f5 expression: 'last(/Fujitsu Primequest 3800E/memoryModules.4.[{#SNMPINDEX}])=4 or last(/Fujitsu Primequest 3800E/memoryModules.4.[{#SNMPINDEX}])=7' name: '{#SNMPVALUE} Warning' priority: AVERAGE - uuid: a0fd462e601342aa877c3f008346ec94 name: '{#SNMPVALUE} Capacity' type: SNMP_AGENT snmp_oid: '.1.3.6.1.4.1.211.1.31.1.1.1.6.5.1.6.{#SNMPINDEX}' key: 'memoryModules.6.[{#SNMPINDEX}]' delay: 10h status: DISABLED value_type: FLOAT description: 'Memory module size (capacity in MBytes; -1 if unknown)' tags: - tag: Application value: Memory - uuid: 91e2b695dc4047dd89d43effe364f1e1 name: 'Discover POWER SUPPLY' type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE}, .1.3.6.1.4.1.211.1.31.1.1.1.6.2.1.3]' key: powerSupply delay: 1h item_prototypes: - uuid: a600742de1764a009fab375fcd002b78 name: '{#SNMPVALUE} Status' type: SNMP_AGENT snmp_oid: '.1.3.6.1.4.1.211.1.31.1.1.1.6.2.1.5.{#SNMPINDEX}' key: 'powerSupply.5.[{#SNMPINDEX}]' history: 30d trends: 90d description: | Power supply status Status mapping. SEL level MIB Value Warning ac-fail(5) Warning predictive-fail(9) Error failed(4) Error not-manageable(8) valuemap: name: 'Primequest 3800E - POWER SUPPLY' tags: - tag: Application value: 'Power supply' trigger_prototypes: - uuid: f34c307ff36943d79552348ce9c19864 expression: 'last(/Fujitsu Primequest 3800E/powerSupply.5.[{#SNMPINDEX}])=4 or last(/Fujitsu Primequest 3800E/powerSupply.5.[{#SNMPINDEX}])=8' name: '{#SNMPVALUE} Status Error' priority: HIGH - uuid: 9372123545e14cb6b42d64cd2bcf8053 expression: 'last(/Fujitsu Primequest 3800E/powerSupply.5.[{#SNMPINDEX}])=5 or last(/Fujitsu Primequest 3800E/powerSupply.5.[{#SNMPINDEX}])=9' name: '{#SNMPVALUE} Status Warning' priority: AVERAGE - uuid: 581ef04335334422b72b56642d5baed2 name: 'Discovety SYSTEM BOARD' type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE}, .1.3.6.1.4.1.211.1.31.1.1.1.6.1.1.1]' key: systemBoard delay: 1h status: DISABLED item_prototypes: - uuid: 74a13e0c074e442597edaf6bf5e47d91 name: 'System Board ID#{#SNMPVALUE} Model Name' type: SNMP_AGENT snmp_oid: '.1.3.6.1.4.1.211.1.31.1.1.1.6.1.1.2.{#SNMPINDEX}' key: 'systemBoard.2.[{#SNMPINDEX}]' delay: 10h trends: '0' status: DISABLED value_type: TEXT description: 'Model name (e.g. ''System Board'')' tags: - tag: Application value: 'System board' - uuid: 543dfa729a564f4aba554c584a7f2f5c name: 'System Board ID#{#SNMPVALUE} Product Number' type: SNMP_AGENT snmp_oid: '.1.3.6.1.4.1.211.1.31.1.1.1.6.1.1.3.{#SNMPINDEX}' key: 'systemBoard.3.[{#SNMPINDEX}]' delay: 10h trends: '0' status: DISABLED value_type: TEXT description: 'Product number (may be identical to ModelName)' tags: - tag: Application value: 'System board' - uuid: 22f5bcffc8134c77a08f52044c0aa12d name: 'System Board ID#{#SNMPVALUE} Revision' type: SNMP_AGENT snmp_oid: '.1.3.6.1.4.1.211.1.31.1.1.1.6.1.1.4.{#SNMPINDEX}' key: 'systemBoard.4.[{#SNMPINDEX}]' delay: 10h trends: '0' status: DISABLED value_type: TEXT description: 'Revision string (e.g. ''WGS1 GS3'')' tags: - tag: Application value: 'System board' - uuid: fb81336f4f1b44a1ae8dd60163995622 name: 'System Board ID#{#SNMPVALUE} Serial Number' type: SNMP_AGENT snmp_oid: '.1.3.6.1.4.1.211.1.31.1.1.1.6.1.1.5.{#SNMPINDEX}' key: 'systemBoard.5.[{#SNMPINDEX}]' delay: 10h trends: '0' status: DISABLED value_type: TEXT description: 'Serial number (not available for all boards)' tags: - tag: Application value: 'System board' - uuid: 422d83ffab5a49338503c595721d6a35 name: 'Discover TEMPERATURE' type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE}, .1.3.6.1.4.1.211.1.31.1.1.1.5.1.1.3]' key: temperatureSensors delay: 1h item_prototypes: - uuid: 7692158d7a534f7185c6f12562f9fab6 name: '{#SNMPVALUE} Status' type: SNMP_AGENT snmp_oid: '.1.3.6.1.4.1.211.1.31.1.1.1.5.1.1.5.{#SNMPINDEX}' key: 'temperatureSensors.5.[{#SNMPINDEX}]' history: 30d trends: 90d valuemap: name: 'Primequest 3800E - TEMPERATURE' tags: - tag: Application value: Temperature trigger_prototypes: - uuid: ad996a9b99474dd886cee9eface19317 expression: 'last(/Fujitsu Primequest 3800E/temperatureSensors.5.[{#SNMPINDEX}])=7 or last(/Fujitsu Primequest 3800E/temperatureSensors.5.[{#SNMPINDEX}])=5' name: '{#SNMPVALUE} Status Error' priority: HIGH - uuid: 42a7567404d94d8e89ceae4e6ebe0c31 expression: 'last(/Fujitsu Primequest 3800E/temperatureSensors.5.[{#SNMPINDEX}])=6' name: '{#SNMPVALUE} Status Warning' priority: AVERAGE - uuid: c240d6b788d147dd89e617061969c924 name: '{#SNMPVALUE} Current Temperature' type: SNMP_AGENT snmp_oid: '.1.3.6.1.4.1.211.1.31.1.1.1.5.1.1.6.{#SNMPINDEX}' key: 'temperatureSensors.6.[{#SNMPINDEX}]' delay: 2m history: 30d trends: 90d tags: - tag: Application value: Temperature - uuid: 9e1eb00ef7db4d319999038ca01760aa name: '{#SNMPVALUE} Temperature Warning Level' type: SNMP_AGENT snmp_oid: '.1.3.6.1.4.1.211.1.31.1.1.1.5.1.1.7.{#SNMPINDEX}' key: 'temperatureSensors.7.[{#SNMPINDEX}]' delay: 1h status: DISABLED valuemap: name: 'Primequest 3800E - TEMPERATURE' tags: - tag: Application value: Temperature - uuid: 375c824b350e452bac65140e007d6b50 name: '{#SNMPVALUE} Temperature Critical Level' type: SNMP_AGENT snmp_oid: '.1.3.6.1.4.1.211.1.31.1.1.1.5.1.1.8.{#SNMPINDEX}' key: 'temperatureSensors.8.[{#SNMPINDEX}]' delay: 1h status: DISABLED valuemap: name: 'Primequest 3800E - TEMPERATURE' tags: - tag: Application value: Temperature - uuid: 74c398c7f2554d5d8362cc0c344c7283 name: '{#SNMPVALUE} Critical Reaction' type: SNMP_AGENT snmp_oid: '.1.3.6.1.4.1.211.1.31.1.1.1.5.1.1.9.{#SNMPINDEX}' key: 'temperatureSensors.9.[{#SNMPINDEX}]' delay: 10h valuemap: name: 'Primequest 3800E - TEMPERATURE CRITICAL REACTION' tags: - tag: Application value: Temperature trigger_prototypes: - uuid: 6cd6a39a7e2a4a3e8197ac2b9e71bbff expression: 'last(/Fujitsu Primequest 3800E/temperatureSensors.6.[{#SNMPINDEX}])=last(/Fujitsu Primequest 3800E/temperatureSensors.8.[{#SNMPINDEX}])' name: '{#SNMPVALUE} Critical Temperature Level' priority: HIGH - uuid: 7fe4a41708be4846a3bd0ec42e8b7b63 expression: 'last(/Fujitsu Primequest 3800E/temperatureSensors.6.[{#SNMPINDEX}])=last(/Fujitsu Primequest 3800E/temperatureSensors.7.[{#SNMPINDEX}])' name: '{#SNMPVALUE} Warning Temperature Level' priority: AVERAGE graph_prototypes: - uuid: 8984d9a546b44c249840062dca1d7a11 name: '{#SNMPVALUE} Temperature' graph_items: - color: 199C0D item: host: 'Fujitsu Primequest 3800E' key: 'temperatureSensors.6.[{#SNMPINDEX}]' - uuid: 98128900d672477d90bb398fd0f70f8d name: 'Discovety VOLTAGE' type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE}, .1.3.6.1.4.1.211.1.31.1.1.1.6.3.1.3]' key: voltages delay: 1h item_prototypes: - uuid: 6a396bca55bd4f2f9c4f57a1569353d0 name: '{#SNMPVALUE} Voltage Status' type: SNMP_AGENT snmp_oid: '.1.3.6.1.4.1.211.1.31.1.1.1.6.3.1.4.{#SNMPINDEX}' key: 'voltages.4.[{#SNMPINDEX}]' history: 30d trends: 90d description: | Voltage status Status mapping. SEL level MIB Value Warning low-warning(7) Warning high-warning(8) Error too-low(4) Error too-high(5) valuemap: name: 'Primequest 3800E - VOLTAGE' tags: - tag: Application value: Voltages trigger_prototypes: - uuid: cd630789e1b0498bbb30cc7eab692724 expression: 'last(/Fujitsu Primequest 3800E/voltages.4.[{#SNMPINDEX}])=4 or last(/Fujitsu Primequest 3800E/voltages.4.[{#SNMPINDEX}])=5' name: '{#SNMPVALUE} Error' priority: HIGH - uuid: e6eef7c3b8ca4bc5b310a7d4590035c9 expression: 'last(/Fujitsu Primequest 3800E/voltages.4.[{#SNMPINDEX}])=7 or last(/Fujitsu Primequest 3800E/voltages.4.[{#SNMPINDEX}])=8' name: '{#SNMPVALUE} Warning' priority: AVERAGE - uuid: ca857d9c1c8042c08e542ea3596f0ef9 name: '{#SNMPVALUE} Voltage Current Value' type: SNMP_AGENT snmp_oid: '.1.3.6.1.4.1.211.1.31.1.1.1.6.3.1.5.{#SNMPINDEX}' key: 'voltages.5.[{#SNMPINDEX}]' delay: 2m history: 30d trends: 90d description: 'Voltage current value. This object returns 0;if the agent can not get the value.(1/100V)' tags: - tag: Application value: Voltages - uuid: 63acafc9f8fb4cadba327cd83a8374a9 name: '{#SNMPVALUE} Voltage Minimum Level' type: SNMP_AGENT snmp_oid: '.1.3.6.1.4.1.211.1.31.1.1.1.6.3.1.7.{#SNMPINDEX}' key: 'voltages.7.[{#SNMPINDEX}]' delay: 1h status: DISABLED description: 'Voltage minimum level (1/100V)' tags: - tag: Application value: Voltages - uuid: ce63a1a8ff3b4eb2b7776d88d350f817 name: '{#SNMPVALUE} Voltage Maximum Level' type: SNMP_AGENT snmp_oid: '.1.3.6.1.4.1.211.1.31.1.1.1.6.3.1.8.{#SNMPINDEX}' key: 'voltages.8.[{#SNMPINDEX}]' delay: 1h status: DISABLED description: 'Voltage maximum level (1/100V)' tags: - tag: Application value: Voltages graph_prototypes: - uuid: 395fa29c042b444e848c6df11765250c name: '{#SNMPVALUE} Voltage Current Value' graph_items: - color: 199C0D item: host: 'Fujitsu Primequest 3800E' key: 'voltages.5.[{#SNMPINDEX}]' valuemaps: - uuid: 7c62c212c91040c7994691028069e417 name: 'Primequest 3800E - CPU' mappings: - value: '1' newvalue: unknown - value: '2' newvalue: not-present - value: '3' newvalue: ok - value: '4' newvalue: disabled - value: '5' newvalue: error - value: '6' newvalue: failed - value: '7' newvalue: missing-termination - value: '8' newvalue: prefailed-warning - uuid: b04ba8f5204f4162910e07d2ebac1645 name: 'Primequest 3800E - DIMM' mappings: - value: '1' newvalue: unknown - value: '2' newvalue: not-present - value: '3' newvalue: ok - value: '4' newvalue: failed-disabled - value: '5' newvalue: error - value: '7' newvalue: warning - value: '8' newvalue: hot-spare - value: '9' newvalue: configuration-error - uuid: 512cf88c6be344beb42acfe1ddf16697 name: 'Primequest 3800E - FAN' mappings: - value: '1' newvalue: unknown - value: '2' newvalue: disabled - value: '3' newvalue: ok - value: '4' newvalue: failed - value: '5' newvalue: prefailed-predicted - value: '6' newvalue: redundant-fan-failed - value: '7' newvalue: not-manageable - value: '8' newvalue: not-present - uuid: 937c734866b54fa1afc07553e8e46748 name: 'Primequest 3800E - FAN FAIL REACTION' mappings: - value: '1' newvalue: unknown - value: '2' newvalue: continue - value: '3' newvalue: shutdown-and-poweroff - uuid: b9e2bf15ce59464f856466e6da378309 name: 'Primequest 3800E - OVERAL STATUS' mappings: - value: '1' newvalue: ok - value: '2' newvalue: degraded - value: '3' newvalue: error - value: '4' newvalue: failed - value: '5' newvalue: unknown - uuid: 925614da4bce48f78658ae07a13f5193 name: 'Primequest 3800E - POWER SUPPLY' mappings: - value: '1' newvalue: unknown - value: '2' newvalue: not-present - value: '3' newvalue: ok - value: '4' newvalue: failed - value: '5' newvalue: ac-fail - value: '6' newvalue: dc-fail - value: '7' newvalue: critical-temperature - value: '8' newvalue: not-manageable - value: '9' newvalue: predictive-fail - uuid: 9ada4184193542ee94e86dde9e05d09d name: 'Primequest 3800E - TEMPERATURE' mappings: - value: '1' newvalue: unknown - value: '2' newvalue: not-available - value: '3' newvalue: ok - value: '5' newvalue: failed - value: '6' newvalue: temperature-warning - value: '7' newvalue: temperature-critical - uuid: 3faa388ee9e34bb49d1c6ef086025bcf name: 'Primequest 3800E - TEMPERATURE CRITICAL REACTION' mappings: - value: '1' newvalue: unknown - value: '2' newvalue: continue - value: '3' newvalue: shutdown-and-poweroff - uuid: 63fa72eb7d2e424bacf9eb5a47e00f46 name: 'Primequest 3800E - VOLTAGE' mappings: - value: '1' newvalue: unknown - value: '2' newvalue: not-available - value: '3' newvalue: ok - value: '4' newvalue: too-low - value: '5' newvalue: too-high - value: '6' newvalue: sensor-failed - value: '7' newvalue: low-warning - value: '8' newvalue: high-warning