5.02021-11-21T21:49:44ZTemplates/StoragesStorage NBU 5240 SNMP TrapStorage NBU 5240 SNMP Trap## Overview
Storage NBU 5240 SNMP Trap Template in Chinese.
1. State of the fan(风扇控制器状态).
2. Power Supply AC Status(电源制器状态) .
3. The Fibre Channel links state(光纤连接状态).
4. State of the System temperature(控制器温度状态).
...
## Author
ZhangQi
Templates/StoragesGerneral- 风扇控制器状态SNMP_TRAPsnmptrap["1.3.6.1.4.1.393.3.9.1.3"]00LOGState is Warning the fan is running slower than the low threshold of 1715 rpm.
State is Failed the fan is missing or has failed.Gerneral%Y/%m/%d %H:%M:%S{nodata(43200)}=0NBU 控制器风扇故障WARNINGYES
- 电源制器状态SNMP_TRAPsnmptrap["1.3.6.1.4.1.393.3.9.1.4"]00LOGStatus is Power Supply AC lost the redundant power supply is not functional.
State is Warning the power supply works abnormalGerneral%Y/%m/%d %H:%M:%S{nodata(43200)}=0NBU 控制器电源故障WARNINGYES
- 光纤连接状态SNMP_TRAPsnmptrap["1.3.6.1.4.1.393.3.9.1.5"]00LOGIf you receive an alert, it means that one or more of the Fibre Channel links is not in an optimal state.Gerneral%Y/%m/%d %H:%M:%S{nodata(43200)}=0NBU 光纤连接故障WARNINGYES
- 控制器温度状态SNMP_TRAPsnmptrap["1.3.6.1.4.1.393.3.9.1.6"]00LOGState is Warning System temperature warningGerneral%Y/%m/%d %H:%M:%S{nodata(43200)}=0NBU 控制器温度超出工作范围WARNINGYES
- CPU 状态SNMP_TRAPsnmptrap["1.3.6.1.4.1.393.3.9.1.7"]00LOGStatus is NULL the firmware was unable to report the current status;
State is Failed status of the CPU is unknown.Gerneral%Y/%m/%d %H:%M:%S{nodata(43200)}=0NBU CPU 故障WARNINGYES
- 磁盘控制器状态SNMP_TRAPsnmptrap["1.3.6.1.4.1.393.3.9.1.8"]00LOGState is Warning the disk is in a foreign, unsupported state;
State is Failed the disk is no longer functional.Gerneral%Y/%m/%d %H:%M:%S{nodata(43200)}=0NBU 控制器磁盘错误WARNINGYES
- RIAD Group 状态SNMP_TRAPsnmptrap["1.3.6.1.4.1.393.3.9.1.9"]00LOGState is Warning The diskgroup has warning
State is Failed the RAID group is failedGerneral%Y/%m/%d %H:%M:%S{nodata(43200)}=0NBU RIAD Group状态异常WARNINGYES
- 存储柜风扇状态SNMP_TRAPsnmptrap["1.3.6.1.4.1.393.3.9.1.10"]00LOGState is Warning the fan is running slower than the low threshold of 2000 rpm.
State is Failed the fan is missing or has failed.Gerneral%Y/%m/%d %H:%M:%S{nodata(43200)}=0NBU 存储柜风扇故障WARNINGYES
- 存储柜电源状态SNMP_TRAPsnmptrap["1.3.6.1.4.1.393.3.9.1.11"]00LOGIf you receive an alert, it means that one of the power supplies has experienced an error.Gerneral%Y/%m/%d %H:%M:%S{nodata(43200)}=0NBU 存储柜电源故障WARNINGYES
- 存储柜工作温度异常状态SNMP_TRAPsnmptrap["1.3.6.1.4.1.393.3.9.1.12"]00LOGState is Warning the temperature is warningGerneral%Y/%m/%d %H:%M:%S{nodata(43200)}=0NBU 存储柜工作温度异常WARNINGYES
- 存储柜磁盘状态SNMP_TRAPsnmptrap["1.3.6.1.4.1.393.3.9.1.13"]00LOGState is Warning, and the Status is Unconfigured (Good) the disk is in a foreign, unsupported state. The disk may have been reinserted and caused an error;
State is Failed, and the Status is Unconfigured (Bad) the disk is failedGerneral%Y/%m/%d %H:%M:%S{nodata(43200)}=0NBU 存储柜磁盘故障WARNINGYES
- RAID 控制卡状态SNMP_TRAPsnmptrap["1.3.6.1.4.1.393.3.9.1.14"]00LOGStatus is NOT OK the adapter has failed;
BBU Status is NOT OK & current Charge is NULL the firmware was unable to report the current charge.Gerneral%Y/%m/%d %H:%M:%S{nodata(43200)}=0NBU RAID Controller异常WARNINGYES
- PCI卡状态SNMP_TRAPsnmptrap["1.3.6.1.4.1.393.3.9.1.16"]00LOGIf you receive an alert, it means that one or more of the PCIe cards are not installed in the correct slots, or a PCIe card is not functional.Gerneral%Y/%m/%d %H:%M:%S{nodata(43200)}=0NBU PCI卡异常WARNINGYES
- 磁盘分区状态SNMP_TRAPsnmptrap["1.3.6.1.4.1.393.3.9.1.21"]00LOGIf you receive an alert, it means that partition has experienced an error.Gerneral%Y/%m/%d %H:%M:%S{nodata(43200)}=0NBU 磁盘分区异常WARNINGYES