5.02021-11-21T21:24:50ZTemplatesSiemens HiPATHSiemens HiPATH## Overview
This template permit to monitor basic OID of Siemens Hipath MIB and all ports of an HiPath system
## Author
Matteo Lobbiani
TemplatesPortSystem- sys hardware versionSNMP_AGENT1.3.6.1.4.1.231.7.2.9.3.1.0hwVersion36000TEXTHARDWARE_FULLSystem
- h150e load levelSNMP_AGENT1.3.6.1.4.1.231.7.2.9.1.7.0loadLevel30%The actual CPU load level (per cent).System
- h150e sys stateSNMP_AGENT1.3.6.1.4.1.231.7.2.9.1.1.0sysState30The actual error state of the device. Contains the highest severity level of the recent error events. This object is updated automatically, but it can also be modified manually.SystemHiPath SysState{last()}>1 and {last()}<5System error stateWARNINGThe actual error state of the device. Contains the highest severity level of the recent error events. This object is updated automatically, but it can also be modified manually.{last()}=5System error state CriticalHIGHThe actual error state of the device. Contains the highest severity level of the recent error events. This object is updated automatically, but it can also be modified manually.
- sys software versionSNMP_AGENT1.3.6.1.4.1.231.7.2.9.3.2.0sysVersion36000TEXTContains the version string of the system software.SOFTWARE_FULLSystem
DevicesSNMP_AGENTdiscovery[{#SNMPVALUE},1.3.6.1.4.1.231.7.2.9.3.8.1.1]h150ePort30Lock State of device $1SNMP_AGENT1.3.6.1.4.1.231.7.2.9.3.8.1.5.{#SNMPINDEX}Lock[{#SNMPVALUE}]607dPortHiPath Lock State{diff()}=1Lock status was changed on {HOST.NAME} interface {#SNMPVALUE}WARNINGState of device $1SNMP_AGENT1.3.6.1.4.1.231.7.2.9.3.8.1.4.{#SNMPINDEX}State[{#SNMPVALUE}]607dPortHiPath State{diff()}=1Operational status was changed on {HOST.NAME} interface {#SNMPVALUE}INFOType of device $1SNMP_AGENT1.3.6.1.4.1.231.7.2.9.3.8.1.3.{#SNMPINDEX}Type[{#SNMPVALUE}]300TEXTPortHiPath Lock State1unlocked2lockedBySoftware3lockedByHardware4lockedBySoftAndHardwareHiPath State1inactive2activeHiPath SysState1normale2warning3minor4major5critical