## ------------------------------------------------------------------ ## WMBUS METER D1 MINI + CC1101 for Diehl IZAR RC 868 I R4 PL ## HARDWARE: D1 MINI ESP8266 80MHz, 80KB RAM, 4MB Flash ## ## usage: 1. Using wM-Bus v2.1.4 ## 2. Using Homassistant API (discovery + devices) ## ## This version shows data from the defined watermeter and ## uses the watermeterID (HEX) from the secrets.yaml file. ## ## WEBUI: http://water-meter-d1mini.local ## ## ------------------------------------------------------------------ substitutions: ## device settings device_name_short: "water-meter-d1mini" device_description: "Watermeter Wemos D1 Mini + EBYTE TI CC1101, IZAR module (Diehl IZAR RC 868 I R4 PL (SzczepanLeon) - my Watermeter" projectname: "Diehl IZAR RC 868.Watermeter" friendly_name: "Watermeter" # device name appversion: "3.0.0" ## logger settings log_level: "WARN" # not that logging need memory, so in production mode use "WARN" log_wmbus: "ERROR" # Loglevel for wmbus meters component log_baudrate: "0" # use 115200 to enable serial UART port logging. ## ---------------------------------------------------------------- ## HARDWARE: D1 MINI ESP8266 80MHz, 80KB RAM, 4MB Flash ## ---------------------------------------------------------------- esp8266: board: d1_mini restore_from_flash: true ## ---------------------------------------------------------------- ## APPLICATION ESPHOME ## ---------------------------------------------------------------- esphome: name: ${device_name_short} comment: ${device_description} # Automatically add the mac address to the name # so you can use a single firmware for all devices name_add_mac_suffix: false project: name: ${projectname} version: ${appversion} build_path: ./build/${device_name_short} on_boot: then: - globals.set: id: boot_counter value: !lambda "return id(boot_counter)+=1;" - globals.set: id: send_millisecond value: !lambda "return millis();" - logger.log: level: WARN tag: "system" format: "BOOTMESSAGE:${device_name_short} API is connected, Device ready!" - component.update: bootcounter on_shutdown: then: - logger.log: level: ERROR tag: "system" format: "BOOTMESSAGE:${device_name_short} is down!" ## --------------------------------------------------- ## External components ## --------------------------------------------------- external_components: # uses the version 3 from SzczepanLeon # https://github.com/SzczepanLeon/esphome-components # You can make ESPHome check the repository every time by setting this option to 0s - source: github://SzczepanLeon/esphome-components@version_3 refresh: 0s components: [wmbus] ## --------------------------------------------------- ## LOGGER COMPONENT ## --------------------------------------------------- logger: id: appslogger level: ${log_level} baud_rate: ${log_baudrate} logs: wmbus: ${log_wmbus} wMBus-lib: ${log_wmbus} sensor: WARN sensor.filter: WARN text_sensor: WARN api.service: ERROR json: ERROR mqtt: WARN scheduler: ERROR wifi: WARN component: ERROR api: WARN # internal_temperature: ERROR ## ---------------------------------------------------------------- ## GLOBALS VARIABLES ## ---------------------------------------------------------------- globals: - id: boot_counter type: int restore_value: yes initial_value: "0" - id: last_value type: float restore_value: yes initial_value: "0.00" - id: current_value type: float restore_value: yes initial_value: "0.00" - id: hour_value type: float restore_value: yes initial_value: "0.00" - id: daily_value type: float restore_value: yes initial_value: "0.00" - id: yesterday_value type: float restore_value: yes initial_value: "0.00" - id: week_value type: float restore_value: yes initial_value: "0.00" - id: lastmonth_value type: float restore_value: yes initial_value: "0.00" - id: year_value type: float restore_value: yes initial_value: "0.00" - id: send_millisecond type: int restore_value: no initial_value: "0" - id: cc1101_state type: int restore_value: no initial_value: "0" - id: alarm_error_text type: std::vector restore_value: no # initial_value: '{"no error", "general_alarm","leakage","meter_blocked","back_flow","underflow","overflow","submarine","sensor_fraud","mechanical_fraud"}' initial_value: '{"Keiner", "Fehler","Zähler undicht","Zähler blockiert","Wasser Rückfluss","Wasser Unterlauf","Wasser Überlauf","Überschwemung","Sensor Fehler", "Mechanischer Fehler"}' - id: cc1101_state_message type: std::vector restore_value: no initial_value: '{"Init", "Warte auf Daten", "Daten empfangem", "Ready", "Error"}' ## --------------------------------------------------- ## WIFI Settings ## --------------------------------------------------- wifi: # Fast connect can only be used with one network!. # fast_connect: true networks: # unifi accesspoint 2.4Ghz - ssid: !secret ssid4_name password: !secret ssid4_pswd priority: 1 # office apple capsulate accesspoint 2.4Ghz - ssid: !secret ssid3_name password: !secret ssid3_pswd priority: 2 # living room apple capsulate accesspoint 2.4Ghz - ssid: !secret ssid2_name password: !secret ssid2_pswd priority: 3 domain: !secret domain ap: # ssid: (Optional, string): The name of the access point to create. Leave empty to use the device name. # ssid: "${device_name_short} Hotspot" password: !secret app_pswd ## --------------------------------------------------- ## mDNS Component ## --------------------------------------------------- mdns: # if mDNS is disabled, they will no longer be able to automatically find your devices. # It is recommended to leave mDNS enabled. disabled: false ## --------------------------------------------------- ## COMPONENT CAPTIVE PORTAL ## --------------------------------------------------- captive_portal: ## --------------------------------------------------- ## OTA COMPONENT ## --------------------------------------------------- ota: password: !secret ota_pswd platform: esphome on_begin: then: - logger.log: format: "OTA Start" tag: "OTA" level: WARN on_progress: then: - logger.log: level: WARN tag: "OTA" format: "OTA progress %0.1f%%" args: ["x"] on_end: then: - logger.log: format: "OTA End" tag: "OTA" level: WARN on_error: then: - logger.log: format: "OTA update error %d" tag: "OTA" level: ERROR args: ["x"] ## --------------------------------------------------- ## COMPONENT WEBSERVER ## --------------------------------------------------- web_server: port: 80 version: 2 js_url: !secret webserver_jsurl ## --------------------------------------------------- ## Home Assistant API COMPONENT ## Homeassistant service call (all values in liter): ## --------------------------------------------------- ## service: esphome.water_meter_set_water_val ## data: ## water_val_hour: 0.03 ## water_val_day: 0.248 ## water_val_yesterday: 0.178 ## water_val_week: 0.248 ## water_val_year: 14.256 ## water_val_lastmonth: 9.59 ## --------------------------------------------------- api: id: espapiwm2_d1 port: 6053 reboot_timeout: 0s # https://esphome.io/components/api.html?highlight=api encryption: key: "inH49O9jBeK5yTGb1X2g4WV/1aS6YKUpu3Vu277fDgw=" services: - service: set_water_val variables: water_val_hour: float water_val_day: float water_val_yesterday: float water_val_week: float water_val_year: float water_val_lastmonth: float then: - globals.set: id: hour_value value: !lambda |- if((water_val_hour) and (water_val_hour)>0.001){ ESP_LOGD("system", "Set hourly value to: %f", water_val_hour); return (water_val_hour); }else{ ESP_LOGD("system", "Skip setting hourly value"); return id(hour_value); }; id(waterhour).publish_state(id(hour_value)); - globals.set: id: daily_value value: !lambda |- if((water_val_day) and (water_val_day)>0.001){ ESP_LOGD("system", "Set daily value to: %f", water_val_day); return (water_val_day); }else{ ESP_LOGD("system", "Skip setting hourly value"); return id(hour_value); }; id(waterday).publish_state(id(daily_value)); - globals.set: id: yesterday_value value: !lambda |- if((water_val_yesterday) and (water_val_yesterday)>0.001){ ESP_LOGD("system", "Set yesterday value to: %f", water_val_yesterday); return (water_val_yesterday); }else{ ESP_LOGD("system", "Skip setting yesterday value"); return id(yesterday_value); }; id(wateryesterday).publish_state(id(hour_value)); - globals.set: id: week_value value: !lambda |- if((water_val_week) and (water_val_week)>0.001){ ESP_LOGD("system", "Set weekly value to: %f", water_val_week); return (water_val_week); }else{ ESP_LOGD("system", "Skip setting weekly value"); return id(week_value); }; id(waterweek).publish_state(id(week_value)); - globals.set: id: lastmonth_value value: !lambda |- if((water_val_lastmonth) and (water_val_lastmonth)>0.001){ ESP_LOGD("system", "Set last month value to: %f", water_val_lastmonth); return (water_val_lastmonth); }else{ ESP_LOGD("system", "Skip setting last month value"); return id(lastmonth_value); }; id(waterlastmonth).publish_state(id(lastmonth_value)); - globals.set: id: year_value value: !lambda |- if((water_val_year) and (water_val_year)>0.001){ ESP_LOGD("system", "Set last yearly value to: %f", water_val_year); return (water_val_year); }else{ ESP_LOGD("system", "Skip setting last yearly value"); return id(year_value); }; id(wateryear).publish_state(id(year_value)); - logger.log: tag: "system" format: "All new Values set: hour: %.3f, day: %.3f, week: %.3f, last month: %.3f, year: %.3f" level: INFO args: [ "id(hour_value)", "id(daily_value)", "id(week_value)", "id(lastmonth_value)", "id(year_value)", ] ## --------------------------------------------------- ## SNTP COMPONENT ## --------------------------------------------------- time: - platform: sntp id: time_sntp timezone: Europe/Berlin servers: - !secret local_sntp - 0.at.pool.ntp.org - 0.pool.ntp.org on_time_sync: # Components should trigger on_time_sync when they update the system clock. then: - if: condition: lambda: 'return id(device_lastBoot_time).state == "";' then: - text_sensor.template.publish: id: device_lastBoot_time state: !lambda return id(time_sntp).now().strftime("%Y-%m-%dT%H:%M:%S %Z"); - logger.log: level: WARN tag: "system" format: "Synchronized sntp clock" - script.execute: set_status_message on_time: # check cc1101 telegram state message - seconds: 30 then: - script.execute: set_status_message # reset hourly value - seconds: 0 minutes: 0 then: - globals.set: id: hour_value value: "0.00" - lambda: id(waterhour).publish_state(id(hour_value)); - logger.log: tag: "system" level: INFO format: "Reset value hour, starting next hour" # reset daily value and set yesterday value - seconds: 0 minutes: 0 hours: 0 then: - lambda: |- id(yesterday_value)=id(daily_value); id(wateryesterday).publish_state(id(yesterday_value)); id(daily_value)=0.00; id(waterday).publish_state(id(daily_value)); - logger.log: tag: "system" level: INFO format: "Set yesterday value and reset value daily, starting new day" # reset weekly value, start new week - seconds: 0 minutes: 0 hours: 0 days_of_week: MON then: - globals.set: id: week_value value: "0.00" - lambda: id(waterweek).publish_state(id(week_value)); - logger.log: tag: "system" level: INFO format: "Reset value weekly, starting new week" # new year, reset yearly value - seconds: 0 minutes: 0 hours: 0 days_of_month: 1 months: JAN then: - globals.set: id: year_value value: "0.00" - lambda: id(wateryear).publish_state(id(year_value)); - logger.log: tag: "system" level: INFO format: "Reset value yearly, starting new year" ## --------------------------------------------------- ## SCRIPTS COMPONENT ## --------------------------------------------------- script: # id(set_status_message).execute(); - id: set_status_message then: - lambda: |- int msgcode = int(id(cc1101_state)); std::string message = id(cc1101_state_message)[msgcode]; ESP_LOGD("wmbus", "cc1101 state message: %s, error code: %d", message.c_str(), msgcode); id(watermeter_status_message).publish_state(message); ## ----------------------------------------------------- ## WMBUS DEVICE D1MINI WEMOS --> EBYTE TI CC1101 ## ----------------------------------------------------- ## ## GDO0 ## o ## 7 ## | GD02 ╭-------o 2 (GND) ## | 6 | ## | o | ## | | | ## ╭――x――x――o――o――x――x――x――o――╮ ## │ D1 D2 - │ ## │ │ ## │ D1MINI WEMOS │ ## ANT │ │ USB ## │ │ ## │ D5 D6 D7 D8 + │ ## ╰――x――x――x――o――o――o――o――o――╯ ## | | | | | ## | | | | ╰-----o 1 (+3.3V) ## | o | o ## | 5 | 8 ## | MISO| CSN ## o o ## 4 3 ## CLK MOSI ## ## -------------------------------------------------- wmbus: mosi_pin: GPIO13 #D7 3: MOSI Attached to Hardware SPI controller MOSI SPI Interface miso_pin: GPIO12 #D6 5: MISO Attached to Hardware SPI controller MISO SPI Interface clk_pin: GPIO14 #D5 4: SCK Attached to Hardware SPI controller CLK cs_pin: GPIO15 #D8 8: CSN Attached to Hardware SPI controller, Controls Boot Mode; CS SPI Interface 10k Pull-Down, boot fails if pulled high !!! gdo0_pin: GPIO05 #D1 7: Clock output. High Impedance ! gdo2_pin: GPIO04 #D2 6: FIFO status signals. High Impedance ! # log_unknown (Optional): Show telegrams from not configured meters in log. log_unknown: False ## --------------------------------------------------- ## Using wmbusmeters i a pipe ## enable this if you have wmbusmeters installed ## --------------------------------------------------- ## clients: ## - name: "wmbusmeters" ## ip_address: !secret wmbusmeter_host ## port: 7227 ## format: rtlwMBus ## transport: UDP ## setting: wmbusmeters.conf ## loglevel: normal ## device: rtlwmbus:CMD(nc -lku 7227) ## donotprobe: /dev/ttyAMA0 ## logtelegrams: false ## format: json ## logfile: /dev/stdout ## shell: /wmbusmeters/mosquitto_pub.sh "wmbusmeters/$METER_NAME" "$METER_JSON" ## --------------------------------------------------- ## led blink mode (optional) xx = PIN ## --------------------------------------------------- # led_blink_time: "100s" ## --------------------------------------------------- ## BINARY SENSOR ## --------------------------------------------------- binary_sensor: # simulate led state - platform: template name: "Wasseruhr Status Led" id: statusled icon: mdi:led-outline entity_category: "diagnostic" lambda: "return id(current_value) > 0;" ## --------------------------------------------------- ## SENSORS ## --------------------------------------------------- sensor: - platform: wmbus # Meter ID (usually from sticker). Can be specified as decimal or hex. # only HEX is working for my watermeter ! # see: https://github.com/SzczepanLeon/esphome-components/issues/6 # edit watermeterid in the secrets file # add_prefix: enable/disable add watermeterid to lqi, rssi, total_water_m3 meter_id: !secret watermeterId type: izar add_prefix: false # The LQI value reported by the CC1101 is a 7 bit unsigned number with a range from 0 to 127. # Note that a lower value indicates a better link. # The LQI of a received packet will be bad (higher number) when there is lot of interference. lqi: id: wmbus_cc1101_lqi name: "${friendly_name} CC1101 LQI" entity_category: "diagnostic" unit_of_measurement: "lqi" state_class: "measurement" # The RSSI value reported by the CC1101 is a 8 bit signed number with an effective # range from -138 dBm to -10.5 dBm when the CC1101 is operating around 868 MHz. # RSSI stands for received signal strength (power) indication (in dBm). # A higher value indicates higher power. (internal only) rssi: id: wmbus_cc1101_rssi name: "${friendly_name} CC1101 RSSI" filters: - lambda: return min(max(2 * (x + 100.0), 0.0), 100.0); unit_of_measurement: "%" entity_category: "diagnostic" state_class: "measurement" icon: mdi:rss # get the total watermter m3 from the wmbus telegram, log the timestamp # for the last reading and calculates the statitics value # and update all sensors: last_value, watercurrent, hour_value, daily_value # week_value, month_value, year_value and watermeter_lastupdate total_water_m3: id: "waterdisplay" name: "Wasseruhr Anzeige" unit_of_measurement: "m³" state_class: total_increasing device_class: "water" accuracy_decimals: 3 icon: mdi:counter # Send the value periodically with the specified time interval. # If the sensor value changes during the interval the interval will not reset. # The last value of the sensor will be sent. 60s means, that every minute the # last state will be published. # The IZAR Watermeter will publish data all 8s (see transmit_period_s), # but we need this only evers minute. # filters: # - heartbeat: 60s # update and calulatet all watermeter sensor data values on_value: then: - lambda: |- if ((id(last_value) > 0.00) and (id(waterdisplay).state)>(id(last_value)) ) { id(cc1101_state) = 2; ESP_LOGI("wmbus", "Water Display value: %.3f, last value: %.3f", id(waterdisplay).state, id(last_value)); id(current_value) = float(id(waterdisplay).state-id(last_value)) * 1000.00; id(watercurrent).publish_state(id(current_value)); id(hour_value)+=id(current_value); id(waterhour).publish_state(id(hour_value)); id(daily_value)+=id(current_value); id(waterday).publish_state(id(daily_value)); id(week_value)+=id(current_value); id(waterweek).publish_state(id(week_value)); id(year_value)+=id(current_value); id(wateryear).publish_state(id(year_value)); ESP_LOGD("wmbus", "Set current value to %.3f litre and publish the data", id(current_value)); }else{ id(current_value) = 0.00; id(cc1101_state) = 1; id(watercurrent).publish_state(id(current_value)); ESP_LOGI("wmbus", "Reset current value to: %.3f, Waterdisplay value: %.3f, last value: %.3f", id(current_value), id(waterdisplay).state, id(last_value)); } id(last_value)=id(waterdisplay).state; # update the timestamp for the last waterdisplay state - text_sensor.template.publish: id: watermeter_lastupdate state: !lambda return id(time_sntp).now().strftime("%Y-%m-%dT%H:%M:%S %Z"); # update the reading timeout for the watermeter display - sensor.template.publish: id: watermeter_read_timeout state: !lambda |- int time_used = ( millis() - id(send_millisecond) ); ESP_LOGD("wmbus", "Diff millisecond is: %d", time_used); id(send_millisecond) = millis(); return float(time_used)/1000; # update the watermeter status - script.execute: set_status_message # update the status led - binary_sensor.template.publish: id: statusled state: !lambda "return id(current_value) > 0;" # water current month (wM-Bus v2.1.4) current_month_total_water_l: name: Wasser Monat id: "watermonth" accuracy_decimals: 2 unit_of_measurement: "L" icon: mdi:water-outline state_class: total_increasing device_class: "water" # get the last month total watermter m3 from the wmbus telegram (wM-Bus 2.1.10) last_month_total_water_m3: name: "Wasseruhr Anzeige letzter Monat" id: "waterdisplay_lastmonth" unit_of_measurement: "m³" state_class: total_increasing device_class: "water" accuracy_decimals: 3 icon: mdi:counter # get the battery life time (wM-Bus v2.1.4) remaining_battery_life_y: name: "Wasseruhr Batterielebensdauer" id: "watermeter_batterie" accuracy_decimals: 2 unit_of_measurement: "Jahre" state_class: "measurement" entity_category: "diagnostic" icon: mdi:battery # get the last transmit periode (wM-Bus v2.1.4) transmit_period_s: name: "Wasseruhr Update Intervall" id: "watermeter_transmit_periode" unit_of_measurement: "sec" state_class: "measurement" accuracy_decimals: 2 entity_category: "diagnostic" icon: mdi:timelapse ## get the current watermeter alarms and publish the text message (wM-Bus 2.1.10) current_alarms: id: "watermeter_current_alarms" name: "Wasseruhr Alarm Code" entity_category: "diagnostic" icon: mdi:message-alert-outline on_value: then: - lambda: |- int error_code = int(x); std::string message = ""; if(error_code==0){ message = id(alarm_error_text)[error_code]; id(watermeter_alarm_message).publish_state(message); ESP_LOGD("wmbus", "Alarm message: %s, error code: %d", message, error_code); }else{ for (int i = 1; i < 10; ++i) { if (error_code & (1 << i)) { if (!message.empty()) { message += ", "; } message += id(alarm_error_text)[i]; } } id(watermeter_alarm_message).publish_state(message); ESP_LOGW("wmbus", "WARNING Alarm message: %s, error code: %d", message.c_str(), error_code); id(watermeter_alarm_timestamp).publish_state(id(time_sntp).now().strftime("%Y-%m-%dT%H:%M:%S %Z").c_str()); } ## get the prevois watermeter alarms and publish the text message (wM-Bus 2.1.10) previous_alarms: id: "watermeter_previous_alarms" name: "Wasseruhr Alarm Code voriger" icon: mdi:message-alert entity_category: "diagnostic" on_value: then: - lambda: |- int error_code = int(x); std::string message = ""; if(error_code==0){ message = id(alarm_error_text)[error_code]; id(watermeter_alarm_message).publish_state(message); ESP_LOGD("wmbus", "Alarm message: %s, error code: %d", message, error_code); }else{ for (int i = 1; i < 10; ++i) { if (error_code & (1 << i)) { if (!message.empty()) { message += ", "; } message += id(alarm_error_text)[i]; } } ESP_LOGW("wmbus", "WARNING Alarm message: %s, error code: %d", message.c_str(), error_code); id(watermeter_alarm_timestamp).publish_state(id(time_sntp).now().strftime("%Y-%m-%dT%H:%M:%S %Z").c_str()); } id(watermeter_alarm_perv_message).publish_state(message); if(id(watermeter_alarm_timestamp).has_state() == false) { id(watermeter_alarm_timestamp).publish_state("--"); } # water current - platform: template name: Wasser Aktuell id: "watercurrent" accuracy_decimals: 2 unit_of_measurement: "L" icon: mdi:water-well state_class: "measurement" device_class: "water" lambda: return (id(current_value)); # water current hour - platform: template name: Wasser Stunde id: "waterhour" accuracy_decimals: 2 unit_of_measurement: "L" icon: mdi:water-well-outline state_class: total_increasing device_class: "water" lambda: return (id(hour_value)); # water today - platform: template name: Wasser Tag id: "waterday" accuracy_decimals: 2 unit_of_measurement: "L" icon: mdi:water-well-outline device_class: "water" state_class: total_increasing lambda: return (id(daily_value)); # water yesterday - platform: template name: Wasser Gestern id: "wateryesterday" accuracy_decimals: 2 unit_of_measurement: "L" icon: mdi:water-well-outline device_class: "water" state_class: total_increasing lambda: return (id(yesterday_value)); # water current week - platform: template name: Wasser Woche id: "waterweek" accuracy_decimals: 2 unit_of_measurement: "L" icon: mdi:water-well-outline device_class: "water" state_class: total_increasing lambda: return (id(week_value)); # water last month - platform: template name: Wasser letzer Monat id: "waterlastmonth" accuracy_decimals: 2 unit_of_measurement: "L" state_class: total_increasing device_class: "water" lambda: return (id(lastmonth_value)); # water current year - platform: template name: Wasser Jahr id: "wateryear" accuracy_decimals: 2 unit_of_measurement: "L" state_class: total_increasing device_class: "water" lambda: return (id(year_value)); # service call delay - platform: template name: Wasseruhr Daten Intervall id: watermeter_read_timeout icon: mdi:clock-start accuracy_decimals: 2 unit_of_measurement: "sec" state_class: "measurement" entity_category: "diagnostic" # Wifi quality RSSI (%) - platform: wifi_signal name: "${friendly_name} WLAN Signal" id: wifi_signal_db update_interval: 60s filters: - lambda: return min(max(2 * (x + 100.0), 0.0), 100.0); entity_category: "diagnostic" unit_of_measurement: "%" # device internal temperature (only webview) # - platform: internal_temperature # name: Device Internal Temperature # id: device_internal_temperature # icon: mdi:thermometer-lines # state_class: "measurement" # update_interval: 60s # entity_category: "diagnostic" # disabled_by_default: true # Uptime device in hours - platform: uptime name: "${friendly_name} Online seit" id: uptime_human icon: mdi:clock-start filters: - lambda: return x / 3600; unit_of_measurement: "h" entity_category: "diagnostic" state_class: "measurement" accuracy_decimals: 2 # device boot counter - platform: template name: "${friendly_name} Boot counter" id: bootcounter icon: mdi:counter accuracy_decimals: 0 state_class: "measurement" entity_category: "diagnostic" lambda: return (id(boot_counter)); ## --------------------------------------------------- ## SWITCHES ## --------------------------------------------------- switch: # reset boot counter value - platform: template name: "${friendly_name} Boot Counter Reset" icon: mdi:lock-reset turn_on_action: then: - lambda: |- id(boot_counter) = 0; id(bootcounter).publish_state(id(boot_counter)); - logger.log: level: WARN tag: "system" format: "${device_name_short} reset boot counter o.k!" - component.update: bootcounter # reset all global vars - platform: template name: "Wasseruhr Reset values" icon: mdi:lock-reset turn_on_action: then: - lambda: |- id(last_value) = 0.00; id(boot_counter) = 0; id(bootcounter).publish_state(id(boot_counter)); id(current_value) = 0.00; id(watercurrent).publish_state(id(current_value)); id(hour_value) = 0.00; id(waterhour).publish_state(id(hour_value)); id(daily_value) = 0.00; id(waterday).publish_state(id(daily_value)); id(yesterday_value) = 0.00; id(wateryesterday).publish_state(id(yesterday_value)); id(week_value) = 0.00; id(waterweek).publish_state(id(week_value)); id(lastmonth_value) = 0.00; id(waterlastmonth).publish_state(id(lastmonth_value)); id(year_value) = 0.00; id(wateryear).publish_state(id(year_value)); - logger.log: level: INFO tag: "system" format: "all values reset!" # restarts the device - platform: restart name: "${friendly_name} Restart" id: restart_switch icon: mdi:restart ## --------------------------------------------------- ## TEXT SENSOR ## --------------------------------------------------- text_sensor: # watermeter status message (updated by script: set_status_message) - platform: template name: "Wasseruhr Status Info" id: watermeter_status_message icon: mdi:bell entity_category: "diagnostic" # watermeter alarm message - platform: template name: "Wasseruhr Alarm" id: watermeter_alarm_message icon: mdi:alarm-light entity_category: "diagnostic" # watermeter previous alarm message - platform: template name: "Wasseruhr Alarm voriger" id: watermeter_alarm_perv_message icon: mdi:alarm-light entity_category: "diagnostic" # watermeter alarm timestamp - platform: template name: "Wasseruhr Alarm Zeit" id: watermeter_alarm_timestamp icon: mdi:alarm-light entity_category: "diagnostic" # optional device version (only on webserver) - platform: version name: "${friendly_name} Version" icon: mdi:application-cog-outline id: appver hide_timestamp: true disabled_by_default: true # Last boot timestamp (only on webserver) - platform: template name: "Device Last Boot" disabled_by_default: true id: device_lastBoot_time icon: mdi:clock-start # waterdisplay timestamp last update - platform: template name: "${friendly_name} Timestamp" id: watermeter_lastupdate icon: mdi:clock-start entity_category: "diagnostic" # optional device timestamp (only for webserver) - platform: template id: systime disabled_by_default: true icon: mdi:clock-start lambda: return id(time_sntp).now().strftime("%Y-%m-%dT%H:%M:%S %Z"); # connected to ssid (only for webserver) # error: src/esphome/components/wifi_info/wifi_info_text_sensor.h:32:49: error: 'class esphome::wifi::WiFiComponent' has no member named 'get_dns_address'; did you mean 'get_ip_address'? # don'nt know how to fix it #- platform: wifi_info # ssid: # name: ${friendly_name} WLAN SSID # id: wlan_ssid # disabled_by_default: true # icon: mdi:wifi-settings