[ { "fileName": "1310-0000-00000011_350c16.ota", "fileVersion": 17, "fileSize": 297306, "url": "https://raw.githubusercontent.com/zigpy/zigpy-ota/2026.1.1/images/aeotec/1310-0000-00000011_350c16.ota", "imageType": 0, "manufacturerCode": 4880, "sha512": "938ddf2b55a72622eb726dfccd01705ff497376d233570b557a4f3bbbe86957d30602669982aef640ce801f016bfe114fc7ebe1a2e29dc401e89de8a9c6fd04b", "otaHeaderString": "EBL Z3RangeExtender", "originalUrl": "https://raw.githubusercontent.com/Aeotec-ccheng/aeotecZigbeeProducts/main/ZigbeeOTAUpdates/Range_Extender_Zi_V1.0.3.ota", "releaseNotes": "- Modified the LED indicator status: When clicking the Action button 4 times to start finding and binding mode, if the device finding & binding is successful, the LED will flash rapidly for 2 seconds and then return to solid state." }, { "fileName": "1310-0802-00000106_1f3467.ota", "fileVersion": 262, "fileSize": 310098, "url": "https://raw.githubusercontent.com/zigpy/zigpy-ota/2026.1.1/images/aeotec/1310-0802-00000106_1f3467.ota", "imageType": 2050, "manufacturerCode": 4880, "sha512": "5a42d396bacb304f9fd8b838b7405e154b4e1975933a125b41337d249e1272b2b3a9ef7b35ebab3273cd8c093fe91fa3ca9008cd09aab787f6fbe1f23fb37571", "otaHeaderString": "EBL SinglePicoSw", "originalUrl": "https://raw.githubusercontent.com/Aeotec-ccheng/aeotecZigbeeProducts/main/ZigbeeOTAUpdates/Pico_Switch_V1.0.6.ota", "releaseNotes": "- Changed the Scene ID configuration for external switch S1/S2" }, { "fileName": "1310-0803-00000106_030d13.ota", "fileVersion": 262, "fileSize": 311594, "url": "https://raw.githubusercontent.com/zigpy/zigpy-ota/2026.1.1/images/aeotec/1310-0803-00000106_030d13.ota", "imageType": 2051, "manufacturerCode": 4880, "sha512": "e60097b31873716ddfab1f3ae8e4ef493216c1535d5f6a1ae207c49daf5b5c6e19ea89fc39bf7e83068253d933c65d472254a11faba4a8066ee3380501615558", "otaHeaderString": "EBL DualPicoSw", "originalUrl": "https://raw.githubusercontent.com/Aeotec-ccheng/aeotecZigbeeProducts/main/ZigbeeOTAUpdates/Pico_Duo_Switch_V1.0.6.ota", "releaseNotes": "- Changed the Scene ID configuration for external switch S1/S2" }, { "fileName": "1310-7C04-00000108_6d687b.ota", "fileVersion": 264, "fileSize": 326978, "url": "https://raw.githubusercontent.com/zigpy/zigpy-ota/2026.1.1/images/aeotec/1310-7C04-00000108_6d687b.ota", "imageType": 31748, "manufacturerCode": 4880, "sha512": "15b3772fa75236fd6e3b8a9b075a7a646903f7a60d202b279a190a025df2c7f6398e7b453c1109e0c9dbfa0f4a441b8b250137ba9f24a45920ede3e0471cf722", "otaHeaderString": "EBL PicoMotor", "originalUrl": "https://raw.githubusercontent.com/Aeotec-ccheng/aeotecZigbeeProducts/main/ZigbeeOTAUpdates/Pico_Shutter_V1.0.8.ota", "releaseNotes": "- Changed the Scene ID configuration for external switch S1/S2" }, { "fileName": "1166-0331-191D3685_650309.ota", "fileVersion": 421344901, "fileSize": 285058, "url": "https://raw.githubusercontent.com/zigpy/zigpy-ota/2026.1.1/images/innr/1166-0331-191D3685_650309.ota", "imageType": 817, "manufacturerCode": 4454, "sha512": "041ac46c276770f7179aed8222a52813d50d981776208fa4fa76bf432f0fa73dc8a09aabfe61894aa734f18fdc997a6842aaee7ab6a4d3554914a42e3fcdca00", "otaHeaderString": "Telink OTA Sample Usage", "originalUrl": "https://github.com/user-attachments/files/24494190/1166-0331-191d3685-sp240-1.9.29.zip", "releaseNotes": "This updates the Innr SP 240 smart plug to firmware version 1.9.29.\n\n**Note:** Please reload ZHA or restart Home Assistant shortly after this update is fully applied to avoid an incorrectly increased \"summation delivered\" state.\n\n**Note:** The relay may turn on or off during the upgrade process.\n\n**Changes compared to version 1.7.23 and older**\n- Fixed attribute reporting failing after power-cycle\n- Improved default attribute reporting settings\n- Improved thresholds for the resettable voltage and current overload protection\n- Added possibility to disable voltage overload protection\n- kWh in 3 decimals instead of 2\n- Added Multiplier and Divisor for kWh\n- Various bug fixes and performance improvements\n\n**Disabling voltage overload protection**\n\nTo disable voltage overload protection:\n1. Keep the button pressed between 15 and 20 seconds, then release\n2. After 5 seconds, the LED will start quick-blinking; keep the button pressed\n3. After 10 seconds, blinking stops; keep the button pressed\n4. After 15 seconds, the LED will start quick-blinking again\n5. Release the button. The LED will slow-blink 3 times to indicate success\n\nEnable again in the same way.\n\nEnabled/disabled state is persisted over power-cycles, even if not connected to a bridge.\nWhile voltage overload protection is disabled, every on/off action will double-blink the LED before assuming final state.\n\nCurrent overload protection cannot be disabled.\n\n**Overload behavior**\n\n- If the voltage or current overload protection triggers, the plug switches off and fast-blinks its LED\n- If the cause was voltage overload, the plug will go back to normal operation automatically when the overload condition disappears\n- If the cause was current overload, the plug will stay off and in overload condition until manually operated, either with the button or by power-cycling" }, { "fileName": "1166-0332-191D3685_9f8062.ota", "fileVersion": 421344901, "fileSize": 285058, "url": "https://raw.githubusercontent.com/zigpy/zigpy-ota/2026.1.1/images/innr/1166-0332-191D3685_9f8062.ota", "imageType": 818, "manufacturerCode": 4454, "sha512": "d3f1728a8b6e70501b21414cb0bbbd17934a56a64d2249500db36e29821a3b5f0551b42c63abbe837426cf657d25fa497585cf86ba6f41209ce40a56cadb9319", "otaHeaderString": "Telink OTA Sample Usage", "originalUrl": "https://github.com/user-attachments/files/24494551/1166-0332-191d3685-sp242-1.9.29.zip", "releaseNotes": "This updates the Innr SP 242 smart plug to firmware version 1.9.29.\n\n**Note:** Please reload ZHA or restart Home Assistant shortly after this update is fully applied to avoid an incorrectly increased \"summation delivered\" state.\n\n**Note:** The relay may turn on or off during the upgrade process.\n\n**Changes compared to version 1.7.23 and older**\n- Fixed attribute reporting failing after power-cycle\n- Improved default attribute reporting settings\n- Improved thresholds for the resettable voltage and current overload protection\n- Added possibility to disable voltage overload protection\n- kWh in 3 decimals instead of 2\n- Added Multiplier and Divisor for kWh\n- Various bug fixes and performance improvements\n\n**Disabling voltage overload protection**\n\nTo disable voltage overload protection:\n1. Keep the button pressed between 15 and 20 seconds, then release\n2. After 5 seconds, the LED will start quick-blinking; keep the button pressed\n3. After 10 seconds, blinking stops; keep the button pressed\n4. After 15 seconds, the LED will start quick-blinking again\n5. Release the button. The LED will slow-blink 3 times to indicate success\n\nEnable again in the same way.\n\nEnabled/disabled state is persisted over power-cycles, even if not connected to a bridge.\nWhile voltage overload protection is disabled, every on/off action will double-blink the LED before assuming final state.\n\nCurrent overload protection cannot be disabled.\n\n**Overload behavior**\n\n- If the voltage or current overload protection triggers, the plug switches off and fast-blinks its LED\n- If the cause was voltage overload, the plug will go back to normal operation automatically when the overload condition disappears\n- If the cause was current overload, the plug will stay off and in overload condition until manually operated, either with the button or by power-cycling" }, { "fileName": "1166-0333-191D3685_ac67dc.ota", "fileVersion": 421344901, "fileSize": 285058, "url": "https://raw.githubusercontent.com/zigpy/zigpy-ota/2026.1.1/images/innr/1166-0333-191D3685_ac67dc.ota", "imageType": 819, "manufacturerCode": 4454, "sha512": "447f8b22c7c9ed1b2d0d4266c9d20087f62c73a5e1f677388747d6050044512f884266565097a9dcc37893345e5d39cf79b99a63ef036296174c8054f7f372e6", "otaHeaderString": "Telink OTA Sample Usage", "originalUrl": "https://github.com/user-attachments/files/24494572/1166-0333-191d3685-sp244-1.9.29.zip", "releaseNotes": "This updates the Innr SP 244 smart plug to firmware version 1.9.29.\n\n**Note:** Please reload ZHA or restart Home Assistant shortly after this update is fully applied to avoid an incorrectly increased \"summation delivered\" state.\n\n**Note:** The relay may turn on or off during the upgrade process.\n\n**Changes compared to version 1.7.23 and older**\n- Fixed attribute reporting failing after power-cycle\n- Improved default attribute reporting settings\n- Improved thresholds for the resettable voltage and current overload protection\n- Added possibility to disable voltage overload protection\n- kWh in 3 decimals instead of 2\n- Added Multiplier and Divisor for kWh\n- Various bug fixes and performance improvements\n\n**Disabling voltage overload protection**\n\nTo disable voltage overload protection:\n1. Keep the button pressed between 15 and 20 seconds, then release\n2. After 5 seconds, the LED will start quick-blinking; keep the button pressed\n3. After 10 seconds, blinking stops; keep the button pressed\n4. After 15 seconds, the LED will start quick-blinking again\n5. Release the button. The LED will slow-blink 3 times to indicate success\n\nEnable again in the same way.\n\nEnabled/disabled state is persisted over power-cycles, even if not connected to a bridge.\nWhile voltage overload protection is disabled, every on/off action will double-blink the LED before assuming final state.\n\nCurrent overload protection cannot be disabled.\n\n**Overload behavior**\n\n- If the voltage or current overload protection triggers, the plug switches off and fast-blinks its LED\n- If the cause was voltage overload, the plug will go back to normal operation automatically when the overload condition disappears\n- If the cause was current overload, the plug will stay off and in overload condition until manually operated, either with the button or by power-cycling" }, { "fileName": "1166-0334-191E3685_0f83d8.ota", "fileVersion": 421410437, "fileSize": 285042, "url": "https://raw.githubusercontent.com/zigpy/zigpy-ota/2026.1.1/images/innr/1166-0334-191E3685_0f83d8.ota", "imageType": 820, "manufacturerCode": 4454, "sha512": "72e94cc57ae49c53e11e98bdd4a24dd08c640e19d3e31b059e1df458aea80b1cc95a8d4edff30ba6b4e173d8d5e70607a833533656e6475bfa51d7c9edb6bc7b", "otaHeaderString": "Telink OTA Sample Usage", "originalUrl": "https://github.com/user-attachments/files/24494583/1166-0334-191e3685-sp240v2-1.9.30.zip", "releaseNotes": "This updates the Innr SP 240 v2 smart plug to firmware version 1.9.30.\n\n**Note:** Please reload ZHA or restart Home Assistant shortly after this update is fully applied to avoid an incorrectly increased \"summation delivered\" state.\n\n**Note:** The relay may turn on or off during the upgrade process.\n\n**Changes compared to version 1.7.23 and older**\n- Fixed attribute reporting failing after power-cycle\n- Improved default attribute reporting settings\n- Improved thresholds for the resettable voltage and current overload protection\n- Added possibility to disable voltage overload protection\n- kWh in 3 decimals instead of 2\n- Added Multiplier and Divisor for kWh\n- Various bug fixes and performance improvements\n\n**Disabling voltage overload protection**\n\nTo disable voltage overload protection:\n1. Keep the button pressed between 15 and 20 seconds, then release\n2. After 5 seconds, the LED will start quick-blinking; keep the button pressed\n3. After 10 seconds, blinking stops; keep the button pressed\n4. After 15 seconds, the LED will start quick-blinking again\n5. Release the button. The LED will slow-blink 3 times to indicate success\n\nEnable again in the same way.\n\nEnabled/disabled state is persisted over power-cycles, even if not connected to a bridge.\nWhile voltage overload protection is disabled, every on/off action will double-blink the LED before assuming final state.\n\nCurrent overload protection cannot be disabled.\n\n**Overload behavior**\n\n- If the voltage or current overload protection triggers, the plug switches off and fast-blinks its LED\n- If the cause was voltage overload, the plug will go back to normal operation automatically when the overload condition disappears\n- If the cause was current overload, the plug will stay off and in overload condition until manually operated, either with the button or by power-cycling" }, { "fileName": "1166-0335-191E3685_500102.ota", "fileVersion": 421410437, "fileSize": 285042, "url": "https://raw.githubusercontent.com/zigpy/zigpy-ota/2026.1.1/images/innr/1166-0335-191E3685_500102.ota", "imageType": 821, "manufacturerCode": 4454, "sha512": "b85050cf4f8352967966df3c65cb550fbaac54b4cd987fc8a0ca176acf42f30b38a0fcfe3b28562d670e630191247d2095b732a2230596feb5c7e8c9599a5044", "otaHeaderString": "Telink OTA Sample Usage", "originalUrl": "https://github.com/user-attachments/files/24494589/1166-0335-191e3685-sp242v2-1.9.30.zip", "releaseNotes": "This updates the Innr SP 242 v2 smart plug to firmware version 1.9.30.\n\n**Note:** Please reload ZHA or restart Home Assistant shortly after this update is fully applied to avoid an incorrectly increased \"summation delivered\" state.\n\n**Note:** The relay may turn on or off during the upgrade process.\n\n**Changes compared to version 1.7.23 and older**\n- Fixed attribute reporting failing after power-cycle\n- Improved default attribute reporting settings\n- Improved thresholds for the resettable voltage and current overload protection\n- Added possibility to disable voltage overload protection\n- kWh in 3 decimals instead of 2\n- Added Multiplier and Divisor for kWh\n- Various bug fixes and performance improvements\n\n**Disabling voltage overload protection**\n\nTo disable voltage overload protection:\n1. Keep the button pressed between 15 and 20 seconds, then release\n2. After 5 seconds, the LED will start quick-blinking; keep the button pressed\n3. After 10 seconds, blinking stops; keep the button pressed\n4. After 15 seconds, the LED will start quick-blinking again\n5. Release the button. The LED will slow-blink 3 times to indicate success\n\nEnable again in the same way.\n\nEnabled/disabled state is persisted over power-cycles, even if not connected to a bridge.\nWhile voltage overload protection is disabled, every on/off action will double-blink the LED before assuming final state.\n\nCurrent overload protection cannot be disabled.\n\n**Overload behavior**\n\n- If the voltage or current overload protection triggers, the plug switches off and fast-blinks its LED\n- If the cause was voltage overload, the plug will go back to normal operation automatically when the overload condition disappears\n- If the cause was current overload, the plug will stay off and in overload condition until manually operated, either with the button or by power-cycling" }, { "fileName": "1166-0336-191E3685_8008e8.ota", "fileVersion": 421410437, "fileSize": 285042, "url": "https://raw.githubusercontent.com/zigpy/zigpy-ota/2026.1.1/images/innr/1166-0336-191E3685_8008e8.ota", "imageType": 822, "manufacturerCode": 4454, "sha512": "857d8d4b4b179f92120072d8084d1f2b5b3e20a94fca6cf76ccc6afbbc8ba8f9e091a30144ab35e6edc6984fb45427289aaf8def4838a065b98cf9728716109d", "otaHeaderString": "Telink OTA Sample Usage", "originalUrl": "https://github.com/user-attachments/files/24494598/1166-0336-191e3685-sp244v2-1.9.30.zip", "releaseNotes": "This updates the Innr SP 244 v2 smart plug to firmware version 1.9.30.\n\n**Note:** Please reload ZHA or restart Home Assistant shortly after this update is fully applied to avoid an incorrectly increased \"summation delivered\" state.\n\n**Note:** The relay may turn on or off during the upgrade process.\n\n**Changes compared to version 1.7.23 and older**\n- Fixed attribute reporting failing after power-cycle\n- Improved default attribute reporting settings\n- Improved thresholds for the resettable voltage and current overload protection\n- Added possibility to disable voltage overload protection\n- kWh in 3 decimals instead of 2\n- Added Multiplier and Divisor for kWh\n- Various bug fixes and performance improvements\n\n**Disabling voltage overload protection**\n\nTo disable voltage overload protection:\n1. Keep the button pressed between 15 and 20 seconds, then release\n2. After 5 seconds, the LED will start quick-blinking; keep the button pressed\n3. After 10 seconds, blinking stops; keep the button pressed\n4. After 15 seconds, the LED will start quick-blinking again\n5. Release the button. The LED will slow-blink 3 times to indicate success\n\nEnable again in the same way.\n\nEnabled/disabled state is persisted over power-cycles, even if not connected to a bridge.\nWhile voltage overload protection is disabled, every on/off action will double-blink the LED before assuming final state.\n\nCurrent overload protection cannot be disabled.\n\n**Overload behavior**\n\n- If the voltage or current overload protection triggers, the plug switches off and fast-blinks its LED\n- If the cause was voltage overload, the plug will go back to normal operation automatically when the overload condition disappears\n- If the cause was current overload, the plug will stay off and in overload condition until manually operated, either with the button or by power-cycling" } ]