{ "manufacturer": "Vision Security", "manufacturerId": "0x0109", "label": "ZD2301EU-5", "description": "4 in 1 Door Sensor", "devices": [ { "productType": "0x201f", "productId": "0x1f20", "zwaveAllianceId": 1334 } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "1", "label": "Temperature Unit", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Celsius", "value": 0 }, { "label": "Fahrenheit", "value": 1 } ] }, { "#": "2", "$purpose": "reporting_threshold.temperature", "label": "Temperature Report Threshold", "valueSize": 1, "unit": "0.1 (°C/°F)", "minValue": 1, "maxValue": 50, "defaultValue": 10 }, { "#": "3", "$purpose": "reporting_threshold.humidity", "label": "Humidity Report Threshold", "valueSize": 1, "unit": "%", "minValue": 1, "maxValue": 50, "defaultValue": 10 }, { "#": "4", "$purpose": "reporting_threshold.brightness", "label": "Luminance Report Threshold", "valueSize": 1, "unit": "%", "allowed": [{ "value": 0 }, { "range": [5, 50] }], "defaultValue": 10, "options": [ { "label": "Disabled", "value": 0 } ] } ], "metadata": { "inclusion": "Press the program switch.", "exclusion": "Press the program switch for at least 1 second.", "reset": "1. Open the rear cover.\n2. Press the program switch 10 times in 10 seconds.", "manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/1334/ZD%202301-5_20150603.pdf" } }